🎉 Your free trial plan has started. Plan will expire in 0 days

West Bengal Power Development Corporation Limited

hooghly, west bengal

AOC value
₹37.55L
AOC date
29 Mar
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 29 Mar 23AOC date

Important info

Result ID
Refer Docs
Award of contract
29/03/2023
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

West Bengal Power Development Corporation Limited has published Procurement Of Lt Power And Control Cables For Emoph And Emiph Dept., Btps. , Procurement Of Lt Power & Control Cables For Emoph & Emiph Dept., Btps. , Cable,3.5Cx240mm2, Al, Xlpe,1.1Kv Grade Armoured Additional Data: Balance Stranded Aluminium Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Strip, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 7098, Part- 1/ 1988 With Latest Amendment. Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/- 5%, Each Core Coded By Different Colour Item Code: M04-C01-00312 Hsn: 8544 , Cable, Al,3.5Cx185 Mm2 # Xlpe Insulated,1.1Kv Grade Additional Data: Balance Stranded Aluminium Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Strip, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 7098, Part- 1/ 1988 With Latest Amendment. Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/- 5%, Each Core Coded By Different Colour Item Code: M04-C01-00098 Hsn: 8544 , Cable,3.5C,120Mm2,1100/1100V, Al# Of 1100 Volt Grade 85Degc Rating Heavy Duty Power Cables With Stranded Alumi Additional Data: Xlpe Insulated, Stranded Aluminium Conductor, Pvc Inner Sheathed Armoured With Galvanized Steel Conforming To Is With Latest Amendment.Minimum Continuous Length: 500 Mtr., Each Core Coded By Different Colour. Item Code: M04-C01-00040 Hsn: 8544 , Cable Al 3.5 Core 95 Mm2 1.1 Kv Armored # Xlpe Insulated,1.1 Kv Grade Additional Data: Balance Stranded Aluminium Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Strip, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 7098, Part- 1/ 1988 With Latest Amendment, Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/- 5%, Each Core Coded By Different Colour Item Code: M04-C01-00232 Hsn: 8544 , Cable, Al,3.5Cx 35 Mm2, Xlpe, Armoured # Cable Lt Power Aluminium Conductor Xlpe Insulated Armoured With Flat Galvanised Steel Strip 1.1Kv Grade 3.5 Core X 35 Sq Mm. Additional Data: Balance Stranded Aluminium Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Strip, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 7098, Part- 1/ 1988 With Latest Amendment, Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/- 5%, Each Core Coded By Different Colour Item Code: M04-C01-00344 Hsn: 8544 , Cable, Aluminium Conductor,16 Mm2,4 Core # Aluminium Conductor 1.1 Grade Stranded Xlpe Insulated Cores Laid Up Pvc Tape Inner Sheathed Single Layer Of Galvanized Flat Steel Strip Armoured Overall Pvc Outer Sheathed Confirming To Is:7098 (Part 1) 1988 With Latest Amendments Size 16 Sq Mm 4 Cor Additional Data: Balance Stranded Aluminium Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Strip, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 7098, Part- 1/ 1988 With Latest Amendment, Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/- 5%, Each Core Coded By Different Colour Item Code: M04-C01-00334 Hsn: 8544 , Cable Cu 12 Core 2.5 Mm2 Armoured 1.1Kv # Cable, Lt, Control Pvc Insulated Steel Armoured,1.1Kv Grade Additional Data: Stranded Copper Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Round Wire, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 1554, Part-1/ 1988 With Latest Amendment, Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/-5%, Each Core Coded By Different Numbers Item Code: M04-C01-00231 Hsn: 8544 , Cable, Copper, Steel Armoured,9Cx2.5Mm2 # Cable, Lt, Control Copper, Pvc Insulated Steel Armoured,1.1Kv Grade 9 Core X 2.5 Sqmm Additional Data: Stranded Copper Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Round Wire, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 1554, Part-1/ 1988 With Latest Amendment, Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/-5%, Each Core Coded By Different Numbers Item Code: M04-C01-00340 Hsn: 8544 , Cable, Control,4C, Cu,2.5 Mm2,1.1Kv # Armoured, Pvc Insulated Additional Data: Stranded Copper Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Round Wire, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 1554, Part-1/ 1988 With Latest Amendment, Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/-5%, Each Core Coded By Different Numbers Item Code: M04-C01-00225 Hsn: 8544 , Cable Al 3.5 Core 95 Mm2 1.1 Kv Armored # Xlpe Insulated,1.1 Kv Grade Additional Data: Balance Stranded Aluminium Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Strip, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 7098, Part- 1/ 1988 With Latest Amendment, Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/- 5%, Each Core Coded By Different Colour Item Code: M04-C01-00232 Hsn: 8544 , Cable, Al,3.5Cx185 Mm2 # Xlpe Insulated,1.1Kv Grade Additional Data: Balance Stranded Aluminium Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Strip, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 7098, Part- 1/ 1988 With Latest Amendment. Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/- 5%, Each Core Coded By Different Colour Item Code: M04-C01-00098 Hsn: 8544 , Cable Cu 12 Core 2.5 Mm2 Armoured 1.1Kv # Cable, Lt, Control Pvc Insulated Steel Armoured,1.1Kv Grade Additional Data: Stranded Copper Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Round Wire, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 1554, Part-1/ 1988 With Latest Amendment, Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/-5%, Each Core Coded By Different Numbers Item Code: M04-C01-00231 Hsn: 8544 , Cable, Copper, Steel Armoured,9Cx2.5Mm2 # Cable, Lt, Control Copper, Pvc Insulated Steel Armoured,1.1Kv Grade 9 Core X 2.5 Sqmm Additional Data: Stranded Copper Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Round Wire, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 1554, Part-1/ 1988 With Latest Amendment, Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/-5%, Each Core Coded By Different Numbers Item Code: M04-C01-00340 Hsn: 8544 , Cable,3.5C,120Mm2,1100/1100V, Al# Of 1100 Volt Grade 85Degc Rating Heavy Duty Power Cables With Stranded Alumi Additional Data: Xlpe Insulated, Stranded Aluminium Conductor, Pvc Inner Sheathed Armoured With Galvanized Steel Conforming To Is With Latest Amendment.Minimum Continuous Length: 500 Mtr., Each Core Coded By Different Colour. Item Code: M04-C01-00040 Hsn: 8544 , Cable,3.5Cx240mm2, Al, Xlpe,1.1Kv Grade Armoured Additional Data: Balance Stranded Aluminium Conductor, Pvc Inner Sheathed, Armoured With Galvanized Steel Strip, Extruded Pvc Type St2 Compound Outer Sheathed, Conforming To Is: 7098, Part- 1/ 1988 With Latest Amendment. Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/- 5%, Each Core Coded By Different Colour Item Code: M04-C01-00312 Hsn: 8544 , Gst, If Any. Last date of submission for this tender is 2023-01-09. This is a Tape Supply tender in Hooghly, West Bengal

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

No Documents Found

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in