🎉 Your free trial plan has started. Plan will expire in 0 days

West Bengal Power Development Corporation Limited

sagardighi, west bengal

AOC value
₹5.15L
AOC date
20 Mar
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 20 Mar 24AOC date

Important info

Result ID
Refer Docs
Award of contract
20/03/2024
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

West Bengal Power Development Corporation Limited has published Procurement Of L And T Make Pmcc And Mcc Miscellaneous Components Used For Lt Drives Stage I Water Package At Sgtpp Wbpdcl Under Emoph Department Procurement Of L And T Make Pmcc And Mcc Miscellaneous Components Used For Lt Drives Stage I Water Package At Sgtpp Wbpdcl Under Emoph Department , Procurement Of L&T Make Pmcc & Mcc Misclleneous Components Used For Lt Drives Stage-I-Water Package At Sgtpp / Wbpdcl Under Emoph Department , Mccb, 160A # Lv 430406X ( Complete Set L&T Electrical & Automation Make 3 Pole Mccb For Motor Back-Up Protection, Type: Dn1-160M, Current Rating: 160 Amps, Breaking Capacity: 50 Ka With L&T Electrical & Automation Make Spreader Link For Dn1, Dn2 - 250 Mccb ( St98053oooo ) , L&T Electrical & Automation Make Dn1 Extended Rom, ( Cm98041oooo ) , L &T Electrical & Automation Make Auxiliary + Trip Alarm Contact ( Cm97890oooo ) L&T Electrical & Automation Make Shunt Release 240 V Ac ( Cm97883omoo ) And Base Plate / Adapter Kit ) , Moulded Case Circuit Breaker ( Mccb ) ( Complete Set L&T Electrical & Automation Make 3 Pole Mccb For Motor Backup, Type: Dn0-100M, Current Rating: 80 Amps, Breaking Capacity: 50 Ka, With L&T Electrical & Automation Make Spreader Link For Dn0-100M Mccb ( Cm97785oooo ) , L&T Electrical & Automation Make Dn0 Extended Rom ( Cm97896oooo ) , L&T Electrical & Automation Make Auxiliary + Trip Alarm Contact ( Cm97890oooo ) , L&T Electrical & Automation Make Shunt Relase 240 V Ac ( Cm97883omoo ) And Base Plate / Adapter Kit ) , Mccb Power Circuit, Tp, 50Ka, 63A ( Complete Set L&T Electrical & Automation Make 3 Pole Mccb For Motor Back-Up Protection, Type: Dn0-100M, Current Rated: 63 Amps, Breaking Capacity: 50 Ka, With L&T Electrical & Automation Make Spreader Link For Dn0-100M ( Cm97785oooo ) , L&T Electrical & Automation Make Extended Rom ( Cm97896oooo ) , L&T Electrical & Automation Make Auxiliary + Trip Alarm Contact ( Cm97890oooo ) , L&T Electrical & Automation Make Shunt Release 240V Ac ( Cm97883omoo ) And Base Plate / Adaptor Kit ) , Mccb, 100A, Dn0-100M For Lt System L&T ( Complete Set L&T Electrical & Automation Make 3 Pole Mccb For Motor Back-Up Protection, Type: Dn0-100M, Current Rated: 100 Amps, Breaking Capacity: 50 Ka, With L&T Electrical & Automation Make Spreader Link For Dn0-100M ( Cm97785oooo ) , L&T Electrical & Automation Make Extended Rom ( Cm97896oooo ) , L&T Electrical & Automation Make Auxiliary + Trip Contact ( Cm97890oooo ) , L&T Electrical & Automation Make Shunt Release 240 V Ac ( Cm97883omoo ) , Base Plate / Adaptor Kit ) , Mccb, 40A, Dn0-100M For Mccb L&T ( Complete Set L&T Electrical & Automation Make 3 Pole Mccb For Motor Back-Up Potection, Type: Dn01-00M, Current Rating: 40 Amps, Breaking Capacity: 50 Ka, With L&T Electrical & Automation Make Spreader Link For Dn0-100 ( Cm97785oooo ) , L&T Electrical & Automation Make Extended Rom ( Cm97896oooo ) , Auxiliary + Trip Alarm Contact ( Cm97890oooo ) , L&T Electrical & Automation Make Shunt Relase 240 V Ac ( Cm97883omoo ) And Base Plate / Adaptor Kit ) , Mpcb # # For Type-Mnx-G0, O / L Release:10.0A-16.0A ( Complete Set L&T Electrical & Automation Make Motor Protection Circuit Breakers, Type: Mog-H1 ( Rotary T Ype ) - Frame 1, Rating: 16 Amps, Thermal Release Range: 11-16 Amps, Instantaneous Trip Current: 208, With L&T Electrical & Automation Make Extended Rom ( St41955oooo ) , L&T Electrical & Automation Make Auxiliary + Trip Alarm Contact ( St41949oooo ) , L&T Electrical & Automation Make Shunt Release 240 V Ac ( St42952oooo ) , And Base Plate / Adaptor Kit ) , Mpcb, 4-6.3A, 3-Pole, 1No +1Nc, Din Rail # Mpcb, 4~6.3A, 3-Pole, 1No +1Nc, Din Rail, Item Pt.No.:Gv2me10 ( L&T Electrical & Automation Make Motor Protection Circuit Breakers, Type: Mog-H1 ( Rotary T Ype ) - Frame 1, Rating: 6.3 Amps, Thermal Release Range: 4-63 Amps, Instantaneous Trip Current: 81.9, With L&T Electrical & Automation Make Extended Rom ( St41955oooo ) , L&T Electrical & Automation Make Auxiliary + Trip Alarm Contact ( St41949oooo ) , L&T Electrical & Automation Make Shunt Release 240 V Ac ( St42952oooo ) ) , Mpcb 10A, Thermal Release :6.3 A-- 10.0A ( Complete Set L&T Electrical & Automation Make Motor Protection Circuit Breakers, Type: Mog-H1 ( Rotary T Ype ) - Frame 1, Rating: 10 Amps, Thermal Release Range: 6.3-10 Amps, Instantaneous Trip Current: 130, With L&T Electrical & Automation Make Extended Rom ( St41955oooo ) , L&T Electrical & Automation Make Auxiliary + Trip Alarm Contact ( St41949oooo ) , L&T Electrical & Automation Make Shunt Release 240 V Ac ( St42952oooo ) , And Base Plate / Adaptor Kit ) , Contactor, Ml2, 400 / 440V Ac # L&T For Power Contactors, 2No + 2Nc, 32A ( L&T Electrical & Automation Make 3 Pole Power Contactor, Type: Ml 2, Ac3 Duty, 2No + 2Nc, Size: Fr2, Coil Voltage: 440 V Ac ( Ss90701pooo ) ) , Mccb, 125A, Tp+N, With O / L, S / C Protectn ( Complete Set L&T Electrical & Automation Make 3 Pole Mccb For Motor Back-Up Protection, Type: Dn1-160M, Current Rated: 125 Amps, Breaking Capacity: 50 Ka, With L&T Electrical & Automation Make Spreader Link For Dn1-160M ( St98053oooo ) , L&T Electrical & Automation Make Extended Rom ( Cm98041oooo ) , L&T Electrical & Automation Make Auxiliary + Trip Alarm Contact ( Cm97890oooo ) , L&T Electrical & Automation Make Shunt Release 240 V Ac ( Cm97883omoo ) , And Base Plate / Adaptor Kit ) , Power Contactor Mnx-140, Coil 240Vac, 50Hz Cat No.Cs94138booo Landt Fitted With Add On Aux. Contacts 2No+2Nc With Extra 1No Add On Aux. Contact Block At 2Nd Left ( 1No + 1Nc ) Which Cat No.Cs94207 Used ( L&T Electrical & Automation Make 3 Pole Power Contactor, Type: Mnx 140, Ac3 Duty, 2No + 2Nc, Size: Fr4, Coil Voltage: 240 V Ac ) , Power Contactor, 3Pole L&T ( L&T Electrical & Automation Make 3 Pole Power Contactor, Type: Mnx 80, Ac3 Duty, Size: Fr3, Coil Voltage: 240 V Ac ( Cs97077booo ) ) , Power Contactor, 240Vac, Mnx-18 Cs94114 With Add On Aux Contact 1No ( L7t Electrical & Automation Make 3 Pole Power Contactor, Type: Mnx 18, Ac3 Duty, 1No, Size: Fr1, Coil Voltage: 240 V ( Cs94100booo ) Ac ) , Add-On Auxiliary Block For Mnx For Circuit Br ( L&T Electrical & Automation Make Add On Auxiliary Contact Block For Mnx 9-80, 1No + 1Nc ( Cs94118oooo ) ) , Add On Block For Contactors, 3No+1Nc # Type-Mnx-A1, 10A, 415V Ac, 3No+1Nc, Cat.No.Cs94113 ( L&T Electrical & Automation Make Add On Auxiliary Contact Block For Mnx 9-80, 3No + 1Nc ( Cs94113oooo ) ) , Aux Contactor, Mxo-22E, 240Vac, 2No+2Nc Coil Voltage-240Vac ( L&T Electrical & Automation Make Control Relay Auxiliary Contactor, Type: Mo0 22E, 2No + 2Nc, Coil Voltage: 240 V ( Cs91625booo ) Ac ) , Thermal Overload Relay, Mn12 90-150A L&T , Ss94138oomo ( L&T Electrical & Automation Make Thermal Overload Relay, Type: Mn 12, Relay Range: 90-150 Amps ( Ss94138oomo ) ) , Overload Relay, Thermal, Mn5, Range:45-75A Cat No:Ss94137oojo ( L&T Electrical & Automation Make Thermal Overload Relay, Type: Mn 5, Relay Range: 45-75 Amps ( Ss94137oojo ) ) , Thermal Overload Relay, Mn5 30-50A L&T , Ss94135oogo ( L&T Electrical & Automation Make Thermal Overload Relay, Type: Mn 5, Relay Range: 30-50 Amps ( Ss94136oojo ) ) , Thermal Overload Relay, Mn5 20-33A L&T , Ss94135ooeo ( L&T Electrical & Automation Make Thermal Overload Relay, Type: Mn 5, Relay Range: 20-33 Amps ( Ss94136ooeo ) ) , Thermal Overload Relay ( L&T Electrical & Automation Make Thermal Overload Relay, Type: Mn 12, Relay Range: 28-46.5 Amps ( Ss94211oogo ) ) , Thermal Overload Relay, Mn5 9-15A L&T , Ss94135oobo ( L&T Electrical & Automation Make Thermal Overload Relay, Type: Mn 2, Relay Range: 9-15 Amps ( Sb94142oobo ) ) , Thermal Overload Relay, Mn2 4.5-7.5A L&T , Ss94141oouo L&T ( L&T Electrical & Automation Make Thermal Overload Relay, Type: Mn 2, Relay Range: 4.5-7.5 Amps ( Ss94141oouo ) ) , Olr, Mn-2, Range-2A-3.3A Ss94141ooqo L&T ( L&T Electrical & Automation Make Thermal Overload Relay, Type: Mn 2, Relay Range: 2-3.3 Amps ( Ss94141ooqo ) ) , O / L Relay: Mn 2, 1.4 - 2.3A For Cooling To ( L&T Electrical & Automation Make Thermal Overload Relay, Type: Mn 2, Relay Range: 1.4-2.3 Amps ( Ss94141oopo ) ) , Selector Switch, 1 Pole, 2 Way ( On & Off ) # L&T Ac 21A 440V-6A / Ac 15 440V 1A Make L&T ( Saizer ) ( L&T Electrical & Automation Make Chnageover Slector Switch, 6 Amps, 1 Pole 2 Way With Off ( 61025Sab13tdyr ) ) , Contactor Mx0 22E, ( 2No+2Nc ) ( L&T Electrical & Automation Make Control Relay Auxiliary Contactor, Type: Mx0 22E, 2No + 2Nc, Coil Voltage: 24 V Dc ( Cs94029ooo ) ) , Trip / Neutral / Close Switch # ( L&T Electrical & Automation Make Breaker Control Switches ( Trip - Neutral - Close ) , Rating: 25 Amps, Contact Arrangement: 2Trip + 2Close, Mounting Type: Standard ( 72009Seb03pgbb ) ) , Hrc Fuse:2A # ( L&T Electrical & Automation Make Cylindrical Hrc Fuse Link, Rated Current: 2 Amps, Szie: 14 X 51, Breaking ( Sf90144oooo ) ) , Relay Reset Cord-400Mm, With Switch # L&T For Mn Type Overload Relay, Cat No: Sb94207# For Mn Type Overload Relay, Cat No:Sb94207 ( L&T Electrical & Automation Make Mn Relay Reset Cord - 400Mm ( Sb94208oooo ) ) , Relay Reset Chord, With Switch ( L&T Electrical & Automation Make Mn Relay Reset Cord - 650Mm ( Sb94208oooo ) ) , Relay Reset Cord-900Mm, With Switch # L&T For Mn Type Overload Relay, Cat No: Sb94209# For Mn Type Overload Relay, Cat No:Sb94209 ( L&T Electrical & Automation Make Mn Relay Reset Cord - 900Mm ( Sb94209oooo ) ) , Relay Reset Cord-1200Mm, With Switch # L&T For Mn Type Overload Relay, Cat No: Sb94210# For Mn Type Overload Relay, Cat No:Sb94210 ( L&T Electrical & Automation Make Mn Relay Reset Cord - 1200Mm ( Sb94210oooo ) ) => Limited. Last date of submission for this tender is 2023-12-28. This is a Din Rail tender in Sagardighi, West Bengal

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

7 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in