University Of Calcutta
- AOC value
- Refer Docs
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Authority
- University Of Calcutta
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
University Of Calcutta has published Tender for Supply, Installation, Testing and Commissioning Of Air Conditioner Machines 100% Copper With Remote Controller For The Lab [ 729] Of Prof Sanjoy Ghosh ,Dept Of Biochemistry & Prof annual repair Banerjee [412] & Prodf D.Mondal[425] Of Dept Of Anthropology With All Related Works, Under University Of Calcutta [Buy Back Of 2 A.C Machines]. , Supply Installation Testing and Commissioning of 3 Star Rating Split Air Cinditioner Machine With R32 Gas Including Remote Controller Of Following Capacity Suitable For Operation On 230V +/- 10% Volt,50Hz Single Phase Ac Supply With Air Cooled Evaporator With Copper Coil,Fan And Fan Motor.Air Cooled Copper Condenser, Hermetically Sealed Copper Compressor,Propeller Fan Control Panels Incl Wirings,Necy Power Cable Connections From Unit To Power Socket,Refrigerant Pipe Of Appropriate Size Between Indoor And Outdoor Unit Upto 3 Mtr Length. Both Suction & Delivery Incl. Gas Charging,Complete As Required Make ; 1.5Trhitachi,Daikin,Blue Star,Voltas Or Equivalent , 2Tr Split Inverter Type 60 Months Warranity,Fast Cool Make Same As Above , Providing And Fixing Copper Pipe With Nitrile Rubber Insulation Not Less Than 0.6Mm Thickness Suitable Size Required For Suction And Return Refrigerant With Suitable Insulation For Above Ac S Complete In All Aspects As Required In Excess Of 3Mtrs / Machine , Supply And Laying 20Mm Dia Isi Marked Flexiblepvc Pipe Along With Accessories On Surface Of The Wall To Drain Out Condensate Water From Indoor Unit 5 To10mm Thickness 3 Dia.3 Thickness 5-10 Mm , S And F Factory Fabricated Ms Structure For Placing The 1.5Tr Capacity Split Outdoor Unit On Existing Building. By Ms Fastner , S Andf 4C Flexib;E Copper Cable Of 4Sq.Mm From Indoor To Outdoor Unit Incl.Connection,Commissioing Testing Etc As Reqd , Less Buy Back For 2 Nos Machine @ Rs For Each Machine [-]. Last date of submission for this tender is 2025-12-15. This is a Air Conditioner tender in Kolkata, West Bengal
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
6 issued- Tender Document 1htmlHTML document
- Tender Document 2xlsxXLSX document
- Tender Document 3pdfPDF document
- Tender Document 4pdfPDF document
- Tender Document 5pdfPDF document
- Tender Document 6pdfPDF document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free