🎉 Your free trial plan has started. Plan will expire in 0 days

State Bank Of India

Distribution And Conditioning
kolkata, west bengal
AOC Value₹2.54 Lac
AOC DateRefer Docs
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
Refer Docs
Authority
State Bank Of India
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
Bidding URL
Tender
Bidder Details

AOC Description

State Bank Of India has published Bids Are invited for Air Conditioning Work At Golf Green Residential Complex Supply - Supply Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant,Wireless Remote Control, Suitable For Working Between 180 To 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100 Percent Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Iseer Value Must Be Minimum Of 5.6.The Ac Must Have 2026 Manufacturing Year The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature).Inverter Type - Cooling Only 1 Tr With 5 Star Bee Rating Ac Make,-Hitachi/Voltas/Bluestar/Daikin /Lg/Panasonic. , Installation Testing And Commissioning - Installation Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant,Wireless Remote Control, Suitable For Working Between 180 To 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100 Percent Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Iseer Value Must Be Minimum Of 5.6.The Ac Must Have 2026 Manufacturing Year The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature).Inverter Type - Cooling Only 1 Tr With 5 Star Bee Rating Ac Make,-Hitachi/Voltas/Bluestar/Daikin /Lg/Panasonic. , Additional Copper Refrigerant Pipe And Additional Cable - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 1 Tr Hi - Wall Split With Addtional Necessary Cables. , Additional Drain Pipe - Supply And Fixing Of Duly Insulated 25Mm Upvc Additional Drain Pipe , Outdoor Stand - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1 Tr Hi-Wall Split Ac.. Last date of submission for this tender is 2026-08-24. This is a Air Conditioner tender in Kolkata, West Bengal

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1html
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in