🎉 Your free trial plan has started. Plan will expire in 0 days

Public Works Department

kolkata, west bengal

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Public Works Department has published tender for Fire Detection System, Air Conditioning work with allied Electrical Installation, SITC of UPS System as well as Fire Detection Systemsfor Establishment of dedicated four bedded HDU Room from previous ERCP Room, Departmentof School of Digestive & Liver Diseasesat 3rd. floor of SDLD Building within the compound of IPGME&R - SSKM Hospital, Kolkata.-Fire Detection System. Sl. No. Item Description 1 Supply, Installation,Testing & Commisioning of IntelligentAddressable multisensor detector with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base as required. (Approval standards:VdS & EN54 Standard (Approved Make: Siemens as per exsisting panel). 2 .Supply, Installation,Testing & Commisioning of Addressable Manual Call Point( VDS /UL / FM / ULC approved )soft addressable type with in built fault isolatoras per NFPA style 7 wiring complete asrequired.(Approved Make: Siemens as per exsisting panel). 3 Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db )cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and( VDS / UL / FM / ULC approved) approved. (Approved Make: Siemens as per exsisting panel). 4 Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc (Approved Make: Siemens as per exsisting panel). 5 Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded Copper Cable (For Loop) (Make. Finolex / KEI ) with 20 mm NB PVC rigid conduit pipe(Make: Precisson-Medium) on the surface of the wall. 6 NOTE :-1) The Fire Alarm system shall comply with latest requirements of--(i) National Fire Protection Association (NFPA) Standards,(ii) IS 2189 ,(iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand. 7 TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. 8 TERMS & CONDITIONS :- 9 The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill.If any refurbished material is supplied and installed, penal action will be taken as per existing rules 10 Defect Liabibility Period 1 (One) year 11 Make & model of each and every material to be approved by EIC . Last date of submission for this tender is 2025-07-04. This is a Flame Detectors tender in Kolkata, West Bengal

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

7 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3xlsx
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in