🎉 Your free trial plan has started. Plan will expire in 0 days

Public Health Engineering Department

kolkata, west bengal

AOC value
₹2.53L
AOC date
2 Feb
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 2 Feb 26AOC date

Important info

Result ID
Refer Docs
Award of contract
02/02/2026
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Public Health Engineering Department has published Supply, Delivery And Installation Of 15 Kva Servo Motor Operated Copper Wound Line Voltage Stabilizer At Ph-1 Of Abad Bhagabanpur Water Supply Scheme Under Mathurapur-Ii Block Under Smd, Phe Dte.- 1 Charges for dismentaling the foundation of existing damaged voltage stabiliser after disconnection of power supply as per direction of EIC 2 Supply and delivery at site of 15 KVA 3 phase, Oil cooled type servo motor operated copper wound line voltage corrector conforming to IS-9815 (Pt-)- 1994 suitable for unbalanced input voltagewith following specification including first filling of oil as per IS-335 where applicable. [Make: Approved make of P.H.E. Dte.] 3 a) Input voltage:- 3 phase main supply may or may not be balanced with respect phase to phase 200V-500V phase to neutral 115V-289V b) Output voltage: 3 phase balanced output voltage. Phase to Phase 400V 0r 415V ± 1% Phase to Neutral 230V or 240V ± 1% [provision should be made to adjust the variation of output voltage per phase by a variable pot well within ± 5% of output] c) Line Regulation: Output voltage should remain well within ± 1% of set voltage [from min to max i.e. either 400V or 415V supply variation] d) Load Regulation: Output voltage should remain neutral well ± 1% of set voltage be (from no load to full load] i.e. either 400V or 415V supply variation) e) Correction speed: Better than 35 Volts second f) Efficiency: Better than 95% on full load g) Cut off limit for [minimum & maximum] by limit switch with audio & visual. h) Metering indication: By selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available. 4 i) Lamp indication: For input and output should be provided [ 3 lamp per side] j) MCCB protection: For input side. k) Load protection: HRC fuse on each output phase should be available. l) Output over shoot: Beyond 210V to 255 volt/phase in case ofMANUAL MODE and voltage protection AUTO MODE operation. m) VISUAL indication for under voltage over voltage of output. n) Manual mode: Up & Down correction with O/P voltage over shoot protection beyond 210V-255Volts per phase o) Nature of cooling: Oil cooled system p) Electric current over load protection q) Circuit for delay outputr) Input high voltage cut off above 470 volts)Mode of Operation: AUTO/ MANUAL with a provision to restore the normal working of the unit STANDBY OPERATION should be available in case of any Electronic failure in auto modet) Auto Mode: Normal / Standby. (Manufacturing test certificate should be provided at the time of delivery). 5 Supply and delivery of following materials: 6 63 Amps 415V 4 pole on load change over switch (side handle) [Make: Approved make of P.H.E. Dte.] 7 63 Amps 415V Rewirable type TPN main switch side handle [Make: Approved make of P.H.E. Dte.] 8 63 Amps 4 way Copper busbar chamber box by 16 SWG Sheet steel enclosure including poecelain chair etc. with painting complete as per direction of the EIC [Make: Approved make of P.H.E. Dte.] 9 25 sq. mm.3.5 core 1.1 KV grade XLPE insulated Al. Ar. Cable as per IS:7098 (Part-II) 1988 with latest amendments [Make: Approved make of P.H.E. Dte.] 10 Making brick built foundation with supplying of all required materials suitable for the above voltage stabilizer by (4:1) cement mortar including down foundation bolts (if required) and plaster with neat cement finish as per direction of EIC. 11 Fitting fixing and connection of above supplied changeover switch, busbar and main switch as in item No. 3.01 to 3.03 on the wall by supplying all necessary materilas to complete the job. 12 Installation of the above voltage stabilizer of item No. 2 on the foundation including connection complete as per direction of EIC. 13 Drawing and connection of cable on wall as in item No.3.40 and all connection complete with all equipments as per requirement and as per direction. 14 Making joints of the cable by supplying compression type gland thimple, socket etc. as per requirement and as per direction. 15 Double earthing the whole installation complying with IE rules including supplying of all necessary earthing materials to complete the job as per direction of EIC. 16 Carrying charges of old damaged voltage stabiliser from working site otnearest store as per direction of EIC. This cost also includes loading unloadin both the ends. 17 Add GST @ 18% 18 Add Cess @ 1% . Last date of submission for this tender is 2025-05-24. This is a Servomotors tender in Kolkata, West Bengal

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

7 issued
  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3xlsx
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in