🎉 Your free trial plan has started. Plan will expire in 0 days

Indian Institute Of Technology

kharagpur, west bengal

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Indian Institute Of Technology has published Design, Site Preparation, Supply, Installation, Testing, Commissioning, And Amc Services Of Basic Infrastructure For The Establishment Of A Data Center At Centre For Computational And Data Sciences (Ccds), Iit Kharagpur , A. Particulars(Supply) (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6) , Civil Works For All Partitions, Fire Rated Glass Works, Doors, False Floor, Road Cutting And Making Good, Building Front Tile Removing Excavation And Filling Up Any Support System, External Wall, Wire Mesh Boundary, Paver Blocks, Wall Breaking And Finishing, External Panel Room. , False Flooring Works (Dc & Electrical Room), Steps & Ramps, Civil And Gypsum Partition, Glass Wall Partitions, Fire Doors, Ante Room, Battery Room Civil Works (Breaking And Finishing Walls), Painting, Finishing, Signages, Branding Works. Grilles/ Tiles Etc. As Required. , Adiabatic Dry Cooler System Along With Pump, Tank, Piping, Controls Panel, Vfd, Pid Controller, Instrumentation As Per P & Id, Adiabatic Tank Etc., Make Up Water , Air Cooled Chiller Plant With Control Panel, Chiller Plant Manager, Auto Restart Feature For Chillers On Restoration Of Power/ Failure Mode, Associated Sensors, Controllers Control Cablings Etc. Pumps, Vfds, Piping Buffer Tanks, Pressurization System, Chemical Dozing System , Chilled Water Pahu With Control Panel, Auto Changeovers, Auto Restart Feature , Chilled Water Rdhx For Data Center Area Along With Flexible Pipes & Controls , Self-Contained Floor Mounted Refrigeration Dehumidifier Derated For 22Oc Operations With Associated Sensors, Controllers Etc. , Ups System With Isolation Transformers For 500Kva And With Incoming And Outgoing Panels As Per Sld. , Ups System With In Built Isolation Transformers For 50Kva With Outgoing Panels As Per Sld. , Li Ion Battery Pack With 10 Minutes Back Up At End Of Life For 500Kva It Loads With 5 Years Warranty , Smf Vrla Battery For Non-It Loads With 15 Minute Back Up , Modification Of Existing Electrical Panels, And Sitc Of Panels And Rest Of Electrical Works As Per Sld. 2 Incoming Panels, 4 Outgoing Panels And Additional Non It Distribution Panel As Required. , End Feed Systems, Bus Ways, Hot Swappable Tap Off Boxes/ Plug In Boxes With 3 X 32A & 1 X16a Iec 60309 Female Receptacles In Each Of 9 Tap Off (2 Spare) Boxes. (Alternative Design May Be Considered To Suit Site/ Bus Ways), 5 Tap Off Boxes (1 Spare) Each With 2 X 40A Plug Ins With Isolators. , Electrical Work As Lighting System Emergency And External Raw Power Lighting, Pump & Dry Cooler Panel Along With Cabling Etc. Earthing Systems With Earth Pits Cable Trays/ Racks/ Etc. Smoke Exhaust System. , I Bms System With Sensors, Cabling, Racks, Computers, Etc. , 800 X 1400Mm/ 1300Mm Racks With Intelligent Pdus With Leveling Etc. Suitable Of 2 Source Power Connections From Top And Provision For Rdhx Installation, Including 2 Sets Of Power Cabling With Connectors To Connect From Tap Off Boxes To Pdu. , Diesel Generator Sets With Day Tanks And Self Standing & Supported Chimneys, Earthing, Fuel Management System, Cabling, Synchronizing Panel, Battery With Chargers, Self Starting, Ats Panel, Fuel Flow Meters And Run Hours With Bms Compatibility For Data Logging. , 2 Years Warrantee For Performance And Workmanship Along With Consumables. , O&M: Deployment Of Onsite Bms, Mep Operators And Supervisor As Per Annexure-K , B. Particulars (Installation) (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6) , Civil Works For All Partitions, Fire Rated Glass Works, Doors, False Floor, Road Cutting And Making Good, Building Front Tile Removing Excavation And Filling Up Any Support System, External Wall, Wire Mesh Boundary, Paver Blocks, Wall Breaking And Finishing, External Panel Room. , False Flooring Works (Dc & Electrical Room), Steps & Ramps, Civil And Gypsum Partition, Glass Wall Partitions, Fire Doors, Ante Room, Battery Room Civil Works (Breaking And Finishing Walls), Painting, Finishing, Signages, Branding Works. Grilles/ Tiles Etc. As Required. , Adiabatic Dry Cooler System Along With Pump, Tank, Piping, Controls Panel, Vfd, Pid Controller, Instrumentation As Per P & Id, Adiabatic Tank Etc., Make Up Water , Air Cooled Chiller Plant With Control Panel, Chiller Plant Manager, Auto Restart Feature For Chillers On Restoration Of Power/ Failure Mode, Associated Sensors, Controllers Control Cablings Etc. Pumps, Vfds, Piping Buffer Tanks, Pressurization System, Chemical Dozing System , Chilled Water Pahu With Control Panel, Auto Changeovers, Auto Restart Feature , Chilled Water Rdhx For Data Center Area Along With Flexible Pipes & Controls , Self-Contained Floor Mounted Refrigeration Dehumidifier Derated For 22Oc Operations With Associated Sensors, Controllers Etc. , Ups System With Isolation Transformers For 500Kva And With Incoming And Outgoing Panels As Per Sld. , Ups System With In Built Isolation Transformers For 50Kva With Outgoing Panels As Per Sld. , Li Ion Battery Pack With 10 Minutes Back Up At End Of Life For 500Kva It Loads With 5 Years Warranty , Smf Vrla Battery For Non-It Loads With 15 Minute Back Up , Modification Of Existing Electrical Panels, And Sitc Of Panels And Rest Of Electrical Works As Per Sld. 2 Incoming Panels, 4 Outgoing Panels And Additional Non It Distribution Panel As Required. , End Feed Systems, Bus Ways, Hot Swappable Tap Off Boxes/ Plug In Boxes With 3 X 32A & 1 X16a Iec 60309 Female Receptacles In Each Of 9 Tap Off (2 Spare) Boxes. (Alternative Design May Be Considered To Suit Site/ Bus Ways), 5 Tap Off Boxes (1 Spare) Each With 2 X 40A Plug Ins With Isolators. , Electrical Work As Lighting System Emergency And External Raw Power Lighting, Pump & Dry Cooler Panel Along With Cabling Etc. Earthing Systems With Earth Pits Cable Trays/ Racks/ Etc. Smoke Exhaust System. , I Bms System With Sensors, Cabling, Racks, Computers, Etc. , 800 X 1400Mm/ 1300Mm Racks With Intelligent Pdus With Leveling Etc. Suitable Of 2 Source Power Connections From Top And Provision For Rdhx Installation, Including 2 Sets Of Power Cabling With Connectors To Connect From Tap Off Boxes To Pdu. , Diesel Generator Sets With Day Tanks And Self Standing & Supported Chimneys, Earthing, Fuel Management System, Cabling, Synchronizing Panel, Battery With Chargers, Self Starting, Ats Panel, Fuel Flow Meters And Run Hours With Bms Compatibility For Data Logging. , 2 Years Warrantee For Performance And Workmanship Along With Consumables. , O&M: Deployment Of Onsite Bms, Mep Operators And Supervisor As Per Annexure-K , C. Additional Items (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6. These Items Will Also Be Considered For Computing L1) , Comprehensive Annual Maintenance Contract -Year-3 , Comprehensive Annual Maintenance Contract -Year-4 , Comprehensive Annual Maintenance Contract -Year-5 , Operation And Maintenance –Year-3 , Operation And Maintenance –Year-4 , Operation And Maintenance –Year-5. Last date of submission for this tender is 2025-08-08. This is a Excavation Work tender in Kharagpur, West Bengal

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in