Eastern Railways
- AOC value
- ₹3.52L
- AOC date
- 13 Aug
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- 13 Aug 25AOC date
- -Published
- -Closes
- -Bid opens
- 13 Aug 2025AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- 13/08/2025
- Authority
- Eastern Railways
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Eastern Railways has published Supply Of 3 Tesla Mri Conditional Dual Chamber Implantable Cardioverter Defibrillator (Icd) Df-4 With Compatible Leads And Accessories, Specification- 3 Tesla Mri Conditional Dual Chamber Implantable Cardioverter Defibrillator (Icd) System (Df-4) With Compatible Artrial And Ventricular Pace / Sense Leads And Option Of Single/Dual Shocking Coil Leads And Accessories. System Should Have Advanced Features For The Reliable Detection And Management Of Ventricular Tachycardia And Ventricular Fibrillation, Including Features To Differentiate Supra-Ventricular Tachycardia From Ventricular Tachycardia And Features To Avoid Inappropriate Shocks, Tiered Therapy Delivery, Choice Of Atp Protocols And Shock Energies, And Should Be Capable Of Delivering Maximum Energy Of 35J Or More And Should Have Features For Management Of High Defibrillation Energy Requirement. Charge Times Should Be Within Clinically Acceptable Limits Throughout The Lifetime Of The Device. Leads Should Be Low Profile And Choice Of Both Active Or Passive Fixation Leads Should Be Available. Should Have Features For Automatically Alerting The Patient In The Event Of A Battery Or Lead Fault. Device Warranty:-Full Replacement International Warranty Of 08 Years Or More. The Oem Must Have Registered Office With Service Personnel Available Round Clock.3 Tesla Mri Conditional Dual Chamber Implantable Cardioverter Defibrillator (Icd) Df-4 With Compatible Leads And Accessories, Specification- 3 Tesla Mri Conditional Dual Chamber Implantable Cardioverter Defibrillator (Icd) System (Df-4) With Compatible Artrial And Ventricular Pace / Sense Leads And Option Of Single/Dual Shocking Coil Leads And Accessories. System Should Have Advanced Features For The Reliable Detection And Management Of Ventricular Tachycardia And Ventricular Fibrillation, Including Features To Differentiate Supra-Ventricular Tachycardia From Ventricular Tachycardia And Features To Avoid Inappropriate Shocks, Tiered Therapy Delivery, Choice Of Atp Protocols And Shock Energies, And Should Be Capable Of Delivering Maximum Energy Of 35J Or More And Should Have Features For Management Of High Defibrillation Energy Requirement. Charge Times Should Be Within Clinically Acceptable Limits Throughout The Lifetime Of The Device. Leads Should Be Low Profile And Choice Of Both Active Or Passive Fixation Leads Should Be Available. Should Have Features For Automatically Alerting The Patient In The Event Of A Battery Or Lead Fault. Device Warranty:-Full Replacement International Warranty Of 08 Years Or More. The Oem Must Have Registered Office With Service Personnel Available Round Clock.,3 Tesla Mri Conditional Dual Chamber Implantable Cardioverter Defibrillator (Ic D) Df-4 With Compatible Leads And Accessories, Specification- 3 Tesla Mri Conditional Dual Chamber Im Plantable Cardioverter Defibrillator (Icd) System (Df-4) With Compatible Artrial And Ventricular Pace / Sense Leads And Option Of Single/Dual Shocking Coil Leads And Accessories. System Should Have Advanced Featu Res For The Reliable Detection And Management Of Ventricular Tachycardia And Ventricular Fibrillation, Incl Uding Features To Differentiate Supra-Ventricular Tachycardia From Ventricular Tachycardia And Features T O Avoid Inappropriate Shocks, Tiered Therapy Delivery, Choice Of Atp Protocols And Shock Energies, And S Hould Be Capable Of Delivering Maximum Energy Of 35J Or More And Should Have Features For Manageme Nt Of High Defibrillation Energy Requirement. Charge Times Should Be Within Clinically Acceptable Limits T Hroughout The Lifetime Of The Device. Leads Should Be Low Profile And Choice Of Both Active Or Passive F Ixation Leads Should Be Available. Should Have Features For Automatically Alerting The Patient In The Even T Of A Battery Or Lead Fault. Device Warranty:-Full Replacement International Warranty Of 08 Years Or More. The Oem Must Have Registered Office With Service Personnel Available Round Clock. [H/St/Acs/Si/Lcd-Dual/ 25-26/Brsh] ] => Limited. Last date of submission for this tender is 2025-08-07. This is a Cardiac Pacemakers And Related Products tender in Sealdah, West Bengal
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free