Eastern Railways
- AOC value
- ₹16.71L
- AOC date
- 21 May
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- 21 May 26AOC date
- -Published
- -Closes
- -Bid opens
- 21 May 2026AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- 21/05/2026
- Authority
- Eastern Railways
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Eastern Railways has published Supply Of 3 Tesla Mri Conditional Combo-Device Crt-D (Df-4) With Quadripolar Lv Lead & Accessories: 1. Pacing Mode - Dddr, Ddd, Ddir, Ddi, Ddt, Door, Vdd, Vvir, Vvi, Vvt, Voo, Ovo, Voor, Aai, Aair, Aat, Aoo, Oao, Aoor. 2. Should Be Capable To Have Anti Trachycardia Pacing (Atp). 3. Should Deliver Shock With 35 Joules. 4. Endocardial Electrodes; A) Right Ventricular With Shock Coils. (I) Steroid Eluting Or Coated Electrode.(Ii) Polyurethane & (Iii) Must Be Negotiated With 7F Or Less Pli In Size. B) Atrial: (I) Steroid Eluting Or Coated Electrode. (Ii) Screw In. & (Iii) Thin Enough To Negotiate With 9F Pli Or Less Ion Size. C) Left Ventricular Electrode With Delivery System: (I) Over The Wire With Both Stylet And Guide Wire Deliver And (Ii) Very Thin Around 4F In Size To Be Lodged In Post-Lateral Vein In Coronary Sinus. 5. Epicardial Electrode: To Be Given If Endocardial Lv Is Not Possible. 6. Delivery System Should Include A Hemostatis Valve B. Peel Away Guiding Catheter And Wire With An Option To Choose From Different Curves Caths And Venogram Apparatus. 7. Must Be Supplied With All Necessary Compatible Plis Along With Fluoroscopy Tube Covers. 8. Must Have At Least 6 Yrs. Of Full Warranty On Ipg Provided By The Parent Company. 9. The Oem Must Have Registered Office With Service Personnel Available Round Clock.3 Tesla Mri Conditional Combo-Device Crt-D (Df-4) With Quadripolar Lv Lead & Accessories: 1. Pacing Mode - Dddr, Ddd, Ddir, Ddi, Ddt, Door, Vdd, Vvir, Vvi, Vvt, Voo, Ovo, Voor, Aai, Aair, Aat, Aoo, Oao, Aoor. 2. Should Be Capable To Have Anti Trachycardia Pacing (Atp). 3. Should Deliver Shock With 35 Joules. 4. Endocardial Electrodes; A) Right Ventricular With Shock Coils. (I) Steroid Eluting Or Coated Electrode.(Ii) Polyurethane & (Iii) Must Be Negotiated With 7F Or Less Pli In Size. B) Atrial: (I) Steroid Eluting Or Coated Electrode. (Ii) Screw In. & (Iii) Thin Enough To Negotiate With 9F Pli Or Less Ion Size. C) Left Ventricular Electrode With Delivery System: (I) Over The Wire With Both Stylet And Guide Wire Deliver And (Ii) Very Thin Around 4F In Size To Be Lodged In Post-Lateral Vein In Coronary Sinus. 5. Epicardial Electrode: To Be Given If Endocardial Lv Is Not Possible. 6. Delivery System Should Include A Hemostatis Valve B. Peel Away Guiding Catheter And Wire With An Option To Choose From Different Curves Caths And Venogram Apparatus. 7. Must Be Supplied With All Necessary Compatible Plis Along With Fluoroscopy Tube Covers. 8. Must Have At Least 6 Yrs. Of Full Warranty On Ipg Provided By The Parent Company. 9. The Oem Must Have Registered Office With Service Personnel Available Round Clock.,3 Tesla Mri Conditional Combo-Device Crt-D (Df-4) With Quadripolar Lv Lead & Accessor Ies: 1. Pacing Mode - Dddr, Ddd, Ddir, Ddi, Ddt, Door, Vdd, Vvir, Vvi, Vvt, Voo, Ovo, Voor, Aai, Aair, Aat, Aoo, Oao, Aoor. 2. Should Be Capable To Have Anti Trachycardia Pacing (Atp). 3. Should D Eliver Shock With = 35 Joules. 4. Endocardial Electrodes; A) Right Ventricular With Shock Coils. (I) Steroi D Eluting Or Coated Electrode.(Ii) Polyurethane & (Iii) Must Be Negotiated With 7F Or Less Pli In Size. B) A Trial: (I) Steroid Eluting Or Coated Electrode. (Ii) Screw In. & (Iii) Thin Enough To Negotiate With 9F Pli Or Less Ion Size. C) Left Ventricular Electrode With Delivery System: (I) Over The Wire With Both Stylet And G Uide Wire Deliver And (Ii) Very Thin Around 4F In Size To Be Lodged In Post-Lateral Vein In Coronary Sinus. 5. Epicardial Electrode: To Be Given If Endocardial Lv Is Not Possible. 6. Delivery System Should Include A Hemostatis Valve B. Peel Away Guiding Catheter And Wire With An Option To Choose From Different Cur Ves Caths And Venogram Apparatus. 7. Must Be Supplied With All Necessary Compatible Plis Along With Fluoroscopy Tube Covers. 8. Must Have At Least 6 Yrs. Of Full Warranty On Ipg Provided By The Parent Co Mpany. 9. The Oem Must Have Registered Office With Service Personnel Available Round Clock. [Ai(2025 -26) , Item Code No.S-62246, Sl No.2021] [ Rate Of Supply 3 Units Per Month , Commencement Time Allowed -1 Day ]. Last date of submission for this tender is 2025-12-08. This is a Medical Equipment tender in Sealdah, West Bengal
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free