🎉 Your free trial plan has started. Plan will expire in 0 days

Power Transmission Corporation Of Uttaranchal Limited

roorkee, uttarakhand

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Power Transmission Corporation Of Uttaranchal Limited has published Supply Installation Testing And Commissioning Of Nifps At 132 Kv Substation Roorkee Bhagwanpur And Bhupatwala Under Oandm Circle Roorkee , Supply , Supply Of Nitrogen Injection Control Panel (Plc Hmi Based) Complete With Mcb,Relays,Buzzers,Indicating Lamps,Operating Switches & Rotary Switches Etc. , Supply Of Fire Extinguishing Cubicle (Fec) Ip55 Approved Consist Of Below Mentioned Items:- (1) N2 Cylinder 1 No. Of 68 Litre Water Capacity Filled With Nitrogen Gascomplete With A Master Valve. (2) Pressureregulatorconsistofpressuregauge&Contact Pressure Gauge (3) Discharge Hose & Pressure Switch (4) N2 Gas Release Unit Consist Of Solenoid Valve (5) Gas Inlet Valve & Non - Return Valve (6) Quick Oil Drain Valve Assembly Consist Of Solenoid Valve (7) Hammer & Rod Mechanism (8) Oil Leakage Unit (9) Service / Isolation Butterfly Valve (System Out Off Service) With Limit Switch. , Supply Of Motorized Transformer Conservator Isolation Valve (Tciv) Including Gasket, Matching Flange Andnut- Bolt. , Supplyofsignalbox/ Junctionboxforterminationof Cable Connection From Tciv And Heat Detectors. , Supply Of Heatdetector Consist Of Limit Switch & Mounting Box 20 Nos , Supply Of Cables With Required Cable Glands As Mentioned Below , Fire Survival Cable From Heat Detector To Junction Box. 2 C X 1.5 Sq. Mm 30 Mtr Appx. , Fire Survival Cable From Tciv To Junction Box. 6 C X 1.5 Sq. Mm 25 Mtr Appx. , Fireretardantlowsmoke(Frls)Armouredcable From Control Panel To Ac & Dc Power Supply Source. 4 C X 1.5 Sq. Mm 50 Mtr Appx. , Fireretardantlowsmoke(Frls)Armouredcable From Fec To Control Panel For System Communication. 12 C X 1.5 Sq. Mm 350 Mtr Appx. , Supply Of Ms Pipe Including Fittinglike Sockets, Bends,Tees, Plug,Nipples,Flanges,Reducer,Welding& Painting, As Mentioned Below , Nitrogen Gas Pipe C Class From Fec To Transformer (25 Nb) 18 Mtr Appx. , Oil Drain Pipe B Class From Transformer To Fec (80 Nb) 12 Mtr Appx. , Oil Drain Pipe B Class From Fec To Oil / Soak Pit (80 Nb) 12 Mtr Appx. , Ms Pipe B Class For Pylon Support With Ms Steel Structural Steel, Angle & Channel Complete In All Respects.(80 Nb) 12 Mtr Appx. , M.S Tank 4 Mm Thick Crca Sheet Housed In Civil Chamber With Bottom Pcc And Brick Wall With Plaster (10% Oil Capacity Of Transformer) , Erection , (Erection Of Nitrogen Injection Control Panel (Plc Hmi Based) Complete With Mcb,Relays,Buzzers,Indicating Lamps,Operating Switches & Rotary Switches Etc. , Erection Of Fire Extinguishing Cubicle (Fec) Ip55 Approved Consist Of Below Mentioned Items (1) N2 Cylinder 1 No. Of 68 Litre Water Capacity Filled With Nitrogen Gascomplete With A Master Valve. (2) Pressureregulatorconsistofpressuregauge&Contact Pressure Gauge (3) Discharge Hose & Pressure Switch (4) N2 Gas Release Unit Consist Of Solenoid Valve (5) Gas Inlet Valve & Non - Return Valve (6) Quick Oil Drain Valve Assembly Consist Of Solenoid Valve (7) Hammer & Rod Mechanism (8) Oil Leakage Unit (9) Service / Isolation Butterfly Valve (System Out Off Service) With Limit Switch. , Erection Of Motorized Transformer Conservator Isolation Valve (Tciv) Including Gasket, Matching Flange Andnut- Bolt. , Erectionofsignalbox/ Junctionboxforterminationof Cable Connection From Tciv And Heat Detectors. , Erectionof Heatdetector Consist Of Limit Switch & Mounting Box 20 Nos , Erection Of Cables With Required Cable Glands As Mentioned Below , Fire Survival Cable From Heat Detector To Junction Box. 2 C X 1.5 Sq. Mm 30 Mtr Appx. , Fire Survival Cable From Tciv To Junction Box. 6 C X 1.5 Sq. Mm 25 Mtr Appx. , Fireretardantlowsmoke(Frls)Armouredcable From Control Panel To Ac & Dc Power Supply Source. 4 C X 1.5 Sq. Mm 50 Mtr Appx. , Fireretardantlowsmoke(Frls)Armouredcable From Fec To Control Panel For System Communication. 12 C X 1.5 Sq. Mm 350 Mtr Appx. , Erection Of Ms Pipe Including Fittinglike Sockets, Bends,Tees, Plug,Nipples,Flanges,Reducer,Welding& Painting, As Mentioned Below , Nitrogen Gas Pipe C Class From Fec To Transformer (25 Nb) 18 Mtr Appx. , Oil Drain Pipe B Class From Transformer To Fec (80 Nb) 12 Mtr Appx. , Oil Drain Pipe B Class From Fec To Oil / Soak Pit (80 Nb) 12 Mtr Appx. , Ms Pipe B Class For Pylon Support With Ms Steel Structural Steel, Angle & Channel Complete In All Respects.(80 Nb) 12 Mtr Appx. , Retrofitting, Rehabilitation, Modification In The Existing Transformer/ Reactors. , Packing, Forwarding, Loading, Freight & Transit Insurance. , M.S Tank 4 Mm Thick Crca Sheet Housed In Civil Chamber With Bottom Pcc And Brick Wall With Plaster (10% Oil Capacity Of Transformer). Last date of submission for this tender is 2025-06-16. This is a Substation tender in Roorkee, Uttarakhand

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

2 issued
  • Tender Document 1pdf
  • Tender Document 2html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in