🎉 Your free trial plan has started. Plan will expire in 0 days

Department Of Posts

thdcil rishikesh, uttarakhand

AOC value
₹40.83L
AOC date
21 Jan
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 21 Jan 21AOC date

Important info

Result ID
Refer Docs
Award of contract
21/01/2021
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Department Of Posts has published Supply , Installation And Commissioning Of Ht And Lt Pannels At Thdcil Complex Rishikesh , Supply , Installation , Testing And Commissioning Of Lt Panel Board ( To Be Connected And Integrate With Existing Panel ) As Per The Following Specificaton . The Panel Should Be Designed As Per The Latest Standard Iec 61439 . The Panel Should Have Busbar Clearance Of 25 Mm For Ph To Ph And 19 Mm For Ph To Neutral , Zero Stray Voltage Doors And Panels , Polyster Glass Support For Insulation . The Cable Alleys Should Be 300 Mm Wide And It Should Be Fitted With Hinged Door That Open Up To And Angle Of 95 Deg . The Provision Of Cable Entry Should Be From Bottom . The Ip Protection Of Panel Should Be Ip-42 For External And Ip2x For Internal With 3B As Form Of Sepration . The Panel Should Be Equiped With Suitable Size Of Ct And Display Meter For Vaf Measurement . Make Of Panel: L&T ( Ti ) , Siemens ( Sivcon ) , Schneider ( Prisma ) A . Incomer Acb 1Nos . 1 . 1250 A , Four Pole , 50 Ka , Mdo Type Air Circuit Breaker With Microprocessor Release Having Lsing Protection . The Breaker Should Have Common Height And Depth Across The Range And Must Have Arc Chute Interlocking For Saftey Of Operators . The Accessories Should Be Front Mounted And Have Tool-Less Fixing Of Voltmetric Release . The Display Of Complete Accessory Information About Acb Should Be At The Front Facia . The Acb Should Have Icu=100% Of Ics , Impulse Voltage 12 Kv , Icm=105Ka , Opening Time Of 40Ms . Make L&T , Siemens , SchneiderB . OutgoingThe Outgoing Feeder Should Consist Of Microprocessor Based Mccb With Inbuilt Earthfault Protection And Front Led Indication Of Overload , Shortcircuit And Earthfault . Make L&T , Siemens , Schneider . 1 . Mccb 4P , 36 Ka , 630 A , Microprocessor Release . 2 Nos . 2 . Mccb 4P , 36 Ka , 250 , Microprocessor Release . 6 Nos . , Supply , Installation , Testing And Commissioning Of Ht Panel ( To Be Connected And Integrate With Existing Panel ) Of Vcb Panel Consisting Of 2 Nos Of Outgoing Vcb Of Rating 800A , 12 Kv , Fault Level 26 . 3 Ka As Per Iec 62271-100 , Iec 62271-102 , 62271-200 . The Panel Should Be Draw Out Type And Readily To Extend On Both Side And Should Comply Following Specs . It Should Be Equipped With Suitable Size/Ratio Ct And Protection Should Be Provided By Mc61anx Relay . 1 . Nominal Current : 800 A2 . Short Time Current Rating : 26 . 3 Ka3 . Duration Of Short Circuit Withstand : 3 Sec . 4 . Making Capacity : 65 . 75 Ka5 . Impulse Withstand Voltage : 75Kvp6 . One Minute Power Frequency Withstand : 28Kv7 . Suitable For Operation Sequence : O-0 . 3 Sec-Co-3 Min-Co8 . Break Time : < 3 Cycles9 . Mechanical Life : > 10 , 000 Operations10 . Degree Of Protection : Ip4x. Last date of submission for this tender is 2020-04-16. This is a Circuit Breakers tender in Thdcil Rishikesh, Uttarakhand

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

No Documents Found

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in