🎉 Your free trial plan has started. Plan will expire in 0 days

Airports Authority Of India

dehradun, uttarakhand

AOC value
₹77.13L
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Airports Authority Of India has published Bids Are invited for Operation And Maintenance Of Electro-Mechanical Installations - Complete System - Annual Comprehensive Maintenance Contract Of Following Capacity & Type Single/Three Phase, Wall/Ceiling Mounted Split Type Ac Units With Stablizer (Wherever Installed) Of All Makes Installed At Different Locations In Airport Including Providing Of All Necessary Consumable Items & Spares , Compressors ( As Per Item), Refrigerent Gas, Burn Out/Worn Out Parts I/C Replacemnt Of Nitrile Insulation Of Refrigerent Piping, Pcb, Blower Fan /Motor, Coil(Evp./Condenser), Etc. Complete As Required As Per Special Conditions Of Contract (This Item Includes Deployment Of Manpower As Per Tender Scc Condition-11 To Keep 100% Servicability All The Time) , 1.5/2 Ton Split Type (1-Ø,50Hz) (With Compressor) (84Nos.X 24 Months = 2016 Jobs.) , 1.5/2 Ton Split Type (1-Ø,50Hz) (Compressor Under Gurarantee ) (20Nos.X 20 Months = 400 Jobs.) , 3 Ton Split Type (3-Ø,50Hz) (With Compressor) (2 Nos.X 24 Months = 48 Jobs.) , 3/3.5 Ton Cassette Type (3-Ø,50Hz) (With Compressor) (4 Nos. X 24 Months = 96 Jobs.) , 3/3.5 Ton Cassette Type (3-Ø,50Hz) (Compressor Under Gurarantee ) (2 Nos. X 20 Months = 40 Jobs.) , 3/3.5/4 Ton Tower Type (3-Ø,50Hz) (With Compressor) (24 Nos. X 24 Months = 576 Jobs.) , 3/3.5/4 Ton Tower Type (3-Ø,50Hz) (Compressor Under Gurarantee ) (15 Nos. X 20 Months = 300 Jobs.) , Annual Comprehensive Maintenance Contract Of Water Coolers Units Of Following Capacity Of All Makes Installed At Different Locations In Airport Including Providing All Necessary Consumable Items & Spares, Compressor, Cleaning Etc & Keeping The Water Quality & Cleaning Record & Display At The Water Cooler By Keeping Maintenance Card Etc. Complete As Required As Per Special Conditions Of Contract. (This Item Includes Deployment Of Manpower As Per Tender Scc Condition-11 To Keep 100% Servicability All The Time) , Up-To Capacity Of 60/120 Ltrs Water Cooler (20 Nos. X 24 Months= 480 Job) , Annual Comprehensive Maintenance Contract With Monthly Routine Service Visit Of R.O. System Of Of Following Capacity (Wherever Installed At The Airport) Including Supply & Replacement Of Power Supply Adaptor Pre/Post-Filter Candle, Activated Carbon, Sediment Filter, Membrane, Ro Pump & Other Associated Accessories Etc And Any Other Defective Part To Maintain The Required Quality & Rated Flow Of Treated Water With Water Level Controller Integrated With Water Cooler . It Also Includes Testing Of Water Quality Of All The Water Coolers At The Quaterly Frequency As Per Relavent Norms Of Potable Drinking Water. (This Item Includes Deployment Of Manpower As Per Tender Scc Condition-11 To Keep 100% Servicability All The Time) , 25 Lph Ro Unit (25 Nos. X 24 Months = 600 Job) , Carrying Out / Making In-Field Measurement/Testing Of Intensity, Beam Spread/Coverage, Orientation, Chromaticity, Luminous Factor, Setting Of Field Alignment, Toe-In Angle, Elevation Angle As Per The Requirement Of Site & Icao/Civil Aviation Requirement (Car) Section-4 Aerodrome Standard & Licensing Series ‘B Part-I, For Inset/ Elevated Type Approach, Runway Edge, Runway End, Threshold, Papi Airfields Ground Lights, By Using Vehicle Mounted Mobile Testing Equipment System / Frame Reader, Submission Of Test Reports Including Re-Testing Of Complete System After Replacement Of Defective Components Found By Aai While Photometry, Like Filter/Prism, Lens (Inner & Outer), Reflector, L Holder, L Etc By Carrying Out In-Field Measurement Of Intensity, Beam Spread/Coverage, Orientation, Chromaticity, Luminous Factor, Setting Of Field Alignment,Toe-In Angle, Elevation Angle Of Airfields Ground Lights Etc. Complete As Required To The Satisfaction Of Engineer-In-Charge.Note :-1) Please Refer Detailed Inventory Of Glf In Tender At Table -Vi.2)On Photometry, If Maintenance Factor (Candela)/Color Chromaticity Is Found Less Than Dgca/ Icao Standards, Then Appropriate Corrective Action Such As Proper Cleaning/ Replacement Of Defective Components Like Filter, Lens (Inner & Outer), Reflector, L Holder, L , Etc. Shall Be Taken By Aai To Maintain The Minimum Accepted Standards.3) Time Required To Carry Out The Replacement Of Defective Components May Very Approx. 2-3 Days Depending On Runway Availibity, Quantum Of Work Or Weather Conditions, Accordingly, Agency Shall Plan The Testing Schedule.. Last date of submission for this tender is 2026-06-17. This is a Electromechanical Machinery tender in Dehradun, Uttarakhand

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in