🎉 Your free trial plan has started. Plan will expire in 0 days

Uttar Pradesh University Of Medical Sciences

etawah, uttar pradesh

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Uttar Pradesh University Of Medical Sciences has published Tender For supply of Dialysis Consumables-1 Haemodialysis AcetateSodium Chloride 172 gm/litrePotassium Chloride 5.49 gm/litreCalcium Chloride 8.12 gm/litreMagnesium Chloride 3.74 gm/litreSodium Acetate 1.50gm/litreDextrose 36.83 gm/litreUSFDA/ISO/EC certificates for quality standards. 2 Haemodialysis dry Granulated BicrbonateSodium Chloride 27.0 gm/litreSodium Bicarbonate 57.0 gm/litreUSFDA/ISO/EC certificates for quality standards. 3 Fistula needle 17 GNeedle Length - 25 mmTube Length 300 mmSiliconised ultra thin walled & sharp beveled with back eye needle.Flexible butterfly wings for proper fixation.Sterilization should be gamma ray/steam sterilePack size in pair.USFDA/ISO/EC certificates for quality standerds. 4 Fistula needle 16 GNeedle Length - 25 mmTube Length 300 mmSiliconised ultra thin walled & sharp beveled with back eye needle.Flexible butterfly wings for proper fixation.Sterilization should be gamma ray/steam sterilePack size in pair.USFDA/ISO/EC certificates for quality standerds. 5 Dialyser with surface area 1.2/1.3 sq/m Effective surface area 1.2/1.3sq/m.Membrane should be polysulphone / Polyethersulphone/ Helixone.Dialyser should be High flux/ middle flux.Inner diameter 200µm, membrane thickness 40 µm, maximum TMP 500-600 mmhg. Sterilization should be steam/ gamma ray sterile.Priming volume approximates 53-60 ml.USFDA/ISO/EC certificates for quality standards. 6 Dialyser with surface area 1.4/1.5 sq/m Effective surface area 1.4/1.5 sq/m.Membrane should be polysulphone/Polyethersulphone/ Helixone.Dialyser should be High flux/ middle flux.Inner diameter 200µm, membrane thickness 40 µm, maximum TMP 500-600 mmhg.Sterilization should be steam/gamma ray sterile.Priming volume approximates 70-80 ml.USFDA/ISO/EC certificates for quality standards. 7 Dialyser with surface area 1.6/1.7 sq/mEffective surface area 1.6/1.7sq/m.Membrane should be polysulphone / Polyethersulphone/ Helixone.Dialyser should be High flux/ middle flux.Inner diameter 200µm, membrane thickness 40 µm, maximum TMP 500-600 mmhg.Sterilization should be steam/ gamma ray sterile.Priming volume approximates 85-95 ml.USFDA/ISO/EC certificates for quality standards. 8 Dialyser with surface area 1.8/1.9 sq/m Effective surface area 1.8/1.9sq/m.Inner diameter 200µm, membrane thickness 40 µm, maximum TMP 500-600 mmhg.Membrane should be polysulphone / Polyethersulphone/ Helixone.Dialyser should be High flux/middle flux.Sterilization should be steam/gamma ray sterile.Priming volume approximates 95-110 ml.USFDA/ISO/EC certificates for quality standards. 9 Dialysis Blood TubingPre and Post blood pump.Material should be soft & kink resistant medical grade PVC.Should have two ports, sampling port in arterial line & injection port in venous line.Venous and artetial sample port should be silicone for multi needle pucture.Arterial line length should be approx. 400 cm.Venous line legth should be approx. 300 cm.Priming volume should be approx. 175-185 ml.Sterilization should be steam/gamma& ETO.USFDA/ISO/EC certificates for quality standards. 10 Double lumen Dialysis Catheter kit (Adult) Curve shape (11.5-12.0 Fr.)Internal jugular double lumen indwelling complete kitLaser cut side slots to avoid positional occlusion.Extension should be silicon & clear.Guide wire should be J tip not straight.Introducing needle should be 18 GauzeOne Scalpel Blade.One hollow syringe for introducing needle.One drape sheet for material & to cover exposed area.Vessel dilator 12.0 fr x 13.0 cm.Vessel dilator 10.0 fr x 13.0 cmSuture needle.Kit should contain tegaderm dressing.Internal jugular dialysis catheter size 11.5 fr.-12.0 fr X 13.5 cm.USFDA/ISO/EC certificates for quality standards. 11 Triple lumen Dialysis Catheter kit (Adult) Curve shape (11.5-12.0 Fr.)Internal jugular triple lumen indwelling complete kitLaser cut side slots to avoid positional occlusion.Extension should be silicon & clear.Guide wire should be J tip not straight.Introducing needle should be 18 GauzeOne Scalpel Blade.One hollow syringe for introducing needle.One drape sheet for material & to cover exposed area.Vessel dilator 12.0 fr x 13.0 cm.Vessel dilator 10.0 fr x 13.0 cmSuture needle.Kit should contain tegaderm dressing.Internal jugular dialysis catheter size 11.5 fr. 12.0 fr X 13.5 cm.USFDA/ISO/EC certificates for quality standards. 12 Hemofilter High Flux 1.4 mmHgEffective Surface area 1.4 square meter.High flux.Transmembrane pressure 600 mmhg.Membrane should be polysuphone/polyethersulphoneInner diameter 200-250µmPriming volume 70-120 ml.Compatible with SCUF, CVVHD, CVVHDF & CVVH.Steam/Gamma Ray sterile 13 Hemofilter High Flux 1.7 mmHgEffective Surface area 0.7 square meter.High flux.Transmembrane pressure 600 mmhg.Membrane should be polysuphone/ polyethersulphoneInner diameter 200-250µmPriming volume 50-80 ml.Compatible with SCUF, CVVHD, CVVHDF & CVVHSteam/Gamma Ray sterile. 14 Filtrate Bag 10 Ltr.Bag capacity should be 5-10L.Medical grade, non toxic, DEHP-free PVC or polyethylene.Sterile and pyrogen free.Tubing connection compatible with dialysis /CRRT machine.Leak proof, capped port for drainage/disposal.Clear volume markings (in litres & millilitres) for accurate measurement.Transparent/semi-transparent for visibility of effluent.Reinforced hanger/handle for attaching on machine stand.Single use (Disposable).Sterlized by ethylene oxide. Pottassium Free LC15 CRRT Fluid-Potassium 0.0 mmol/LSodium 140 mmol/LCalcium 1.5 mmol/LMagnesium 0.50 mmol/LChloride 109 mmol/LSodium Bicarbonate 35 mmol/LGlucose 5.55 mmol/LpH 7.4 15 Pottassium 2.0 mmol/L Kalium-LC15 CRRT FluidPotassium 2.0 mmol/LSodium 140 mmol/LCalcium 1.5 mmol/LMagnesium 0.50 mmol/LChloride 111 mmol/LSodium Bicarbonate 35 mmol/LGlucose 5.55 mmol/LpH 7.4 16 Pottassium 4.0 mmol/L Kalium-LC15 CRRT FluidPotassium 4.0 mmol/LSodium 140 mmol/LCalcium 1.5 mmol/LMagnesium 0.50 mmol/LChloride 113 mmol/LSodium Bicarbonate 35 mmol/LGlucose 5.55 mmol/LpH 7.4 17 Hemofiltration CassetteCassette should incude arterial line, Venuos line, Substitute line And Filtrate line.It should be compatible with different modes: CVVH, CVVHD, CVVHDF SCUFBlood volume should be 240-280ml.Cassette includes for collecting ultrafiltrate, filtrate/ Dialysate and substution fluid line depending on therapy.Material should be medical grade PVC compatible with blood.Sterile with steam sterile / gamma ray. . Last date of submission for this tender is 2026-02-25. This is a Gaseous Fuels tender in Etawah, Uttar Pradesh

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in