🎉 Your free trial plan has started. Plan will expire in 0 days

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited

Distribution And Conditioning
sonbhadra, uttar pradesh
AOC Value₹33.6 Lac
AOC DateRefer Docs
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
Refer Docs
Authority
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
55(00)/2025-2026/XXX/5XX
Bidding URL
https://www.exampletenders.gov.in/bid/98765
Tender
View Tender
Bidder Details
Bidder Name: Mr. Jhon Doe, Ranking 2

AOC Description

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited has published Bids Are invited for Servicing of motor operated M-BFP discharge isolation valves, control & isolating valves on feed water lines, Ist/IInd discharge NRVs of M-BFP, manually operated gate/globe valves installed of HP lines on Turbine side. Size: 250~300mm, Design press.: > 40 Kg/cm2, temp.: 250 oC , Servicing of motor operated discharge isolation valve, Ist / IInd. discharge NRVs of T-BFPs, control & isolating valves on feed water lines. Size:350 mm,Design press.: 219~302 Kg/cm2, temp.:210 oC , Servicing of feed water minimum flow isolation valves, pneumatically operated control valves on Turbine side. Size:150 mm, Pr. : 219~224 Kg/cm2 , Servicing of motor operated control valve, motor operated gate/globe valves, manually operated gate/globe valves, check valves Size:150~250 mm & manually operated valves of Size: 15~100mm installed on HP lines. motor operated valves. Size: 25~100 mm Pr.> 40 Kg/cm2 , Servicing of hydraulic operated HP Bypass spray water control valves, spray isolation valves, NRVs on Turbine side. Size:100-150mm, Pr. : 152 Kg/cm2. , Servicing of HPH 5A, 5B, 6A, 6B Extraction steam valve, check valves. Size: 250mm, Pr.: 40~51Kg/cm2 , Servicing/Overhauling of CRH reverse current valve. Size:900 mm, Pr: 51 Kg/ cm2. , Replacement of HP / LP valves of different Floors by cutting of damaged valve & welding of new valve. Size: 08~25 mm. , Replacement of flange gasket of HP/LP valves & piping on per mm dia.basis of valve. , Replacement of gland packing with new one of HP / LP Valves on per mm dia. basis of valve. , Replacement of HP / LP Heater man hole flange gasket. , Servicing of HPH - 5A/5B, 6A/6B, LPH-2&3, deaerator & Gland steam header safety valve. , Servicing of suction relief valves of T-BFPs / M-BFPs / CEPs / LPHs / HPHs and safety valves of main air ejectors. , Servicing of motor operated/control & isolation valves installed on LP lines. Size: 25~100mm, Pr. <40 Kg/cm2. , Servicing of motor operated / control & isolation valves installed on LP lines. Size: 150~200mm, Press<40 Kg/cm2. , Servicing of motor operated/control & isolation valves installed on LP lines. Size: 250~650 mm, Press<40 Kg/cm2. , Servicing of mannual operated gate/globe valves & NRVs installed on LP lines. Size: 15~100mm, Pr. <40 Kg/cm2. , Servicing of mannual operated gate/ globe valves & NRVs installed on LP lines. Size:150~350mm, Press<40 Kg/cm2. , Servicing of mannual operated gate/ globe valves & NRVs installed on LP lines. Size: 400~650mm, Press < 40 Kg/cm2. , Servicing of steam drain trap valve. Size: 40~50mm, Pr. < 40Kg/cm2. , Revisioning/ Servicing of Butterfly valves installed on ACW System & Gland steam system.Size:150~350mm. , Revisioning / Servicing of Butterfly valves of ACW System. Size: 450~750mm , Revisioning / Servicing of NRVs installed on ACW System. Size: 500mm. , Revisioning / Servicing of NRVs installed on SRW System. Size: 750mm. , Servicing of gear boxes of various valves installed on ACW System, feed water, condensate & steam line. Valve Size: 100~750 mm. , Servicing of gear boxes of various valves provided at condenser inlet & outlet in CW line and BFP-T exhaust to condenser. Valve Size: 1350-2100 mm. , Revisioning/Servicing of butterfly valves of BFP-T exhaust to condenser. Size:1350 mm. , Revisioning/Servicing of butterfly valves provided at condenser inlet & outlet in circulating water line. Size:2100 mm. , Welding/repair of LP pipings attending leakages of pipe lines & headers etc. by cutting the damaged portions. , Revisioning / Servicing of Ventilator valve. , Replacement of flange type gate/globe valves of M-BFP & T-BFP oil coolers / LP lines Size: 80 -100 mm , Replacement of butt welded gate/globe valves of M-BFP & T-BFP oil coolers/LP linesSize: 80-100 mm , Revisioning/Servicing of NRVs installed on sump pump pipe lines on Turbine side. Size: 50-100 mm. , Revisioning / Servicing of Ball Collector of Condenser Tube Cleaning System. , Inspection/minor repairing of ball catch strainer of condenser tube cleaning system installed inside CW return line of size:2100 mm , Revisioning/Servicing of ball type valves installed on condenser tube cleaning system on Turbine side. Size:15-40 mm. , Revisioning/Servicing of ball type valves installed on condenser tube cleaning system on Turbine side. Size: 65 -100 mm. , Inside inspection and minor repairing of HP/LP Flash Tanks. , Inspection/Repairing of nozzle of starting air ejector. , Replacement of HP / LP valves of different Floors by cutting of damaged valve & welding of new valve. Size: 40~65 mm. , Inspection and O/H of nozzles of Steam Jet Air Ejector. , Inside inspetion of CW outlet duct by opening of its manhole , Revisioning / Servicing of HP Heater Bypass Valve BF-031-EGV , Revisioning / Servicing of Isolating valve for Superheater spray water SP-031-MGV , Replacement of Main Steam line drain / HPBP Spray valves & other similar valves of size Nb-80~100 mm, Pr. > 40 Kg/cm2, Temp. > 540 oC , Putting the new Spool Piece for replacement of Main Steam line drain /HPBP Spray valves & other similar valves of size Nb-80~100 mm, Pr. > 40 Kg/cm2, Temp. > 540 oC , Replacement of LP Valves of size Nb-300 mm, Pressure rating < 40 Kg/cm2. , Putting the new Spool Piece for replacement of LP Valves of size Nb-300 mm, Pressure rating < 40 Kg/cm2. , Replacement of LP Valves of Nb-350 mm, Pressure Rating < 40 Kg/cm2. , Putting the new Spool Piece for replacement of LP Valves of Nb-350 mm, Pressure Rating < 40 Kg/cm2. , Replacement of LP Valves of Nb-250 mm, Pressure Rating < 40 Kg/cm2. , Replacement of Heater Level Control Valves, isolating valves & NRVs of Pressure Rating < 40 Kg/cm2. , Attending Feed Water Leakage in HP Heater’s , Overhauling /Servicing of LP Heaters. Last date of submission for this tender is 2026-06-01. This is a Control Valves tender in Sonbhadra, Uttar Pradesh

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1html
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
Sharma infra projects pvt ltd
₹1,24,50,000.00L1
Verma constructions ltd
₹1,31,00,000.00L2
Nair engineering works
₹1,38,75,000.00L3
Iyer industrial solutions
₹1,43,20,000.00L4
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in