🎉 Your free trial plan has started. Plan will expire in 0 days

Uttar Pradesh Power Transmission Corporation Limited

lucknow, uttar pradesh

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Uttar Pradesh Power Transmission Corporation Limited has published Tender For Supply Of Material And Work Sechudle For Strengthening Of132kv Sgpgi Ckt-I &Iibay At 220 Kv Substation Bijnaurand 132Kv Bijnaur Ckt-I &Iibay At 132 Kv Substation Sgpgi For Replacement Of Panther Conductor With Htls Of 132Kv Bijnaur -Sgpgi Ckt-I &Ii Transmission Lines - P.G Clamp ACSR Panther to Panther conductor 3 P.G Clamp ACSR Moose to Panther conductor 4 P.G Clamp ACSR Moose to Moose conductor 5 Spacer for Twin Moose Conductor 02 Bolts, 100 mm spacing made of Aluminium alloy LM-6 complete with nuts,bolts & washers confirming to BIS:5561 6 Spacer for Twin Panther Conductor 02 Bolts, 100 mm spacing made of Aluminium alloy LM-6 complete with nuts,bolts & washers confirming to BIS:5561 7 Spacer for Twin Moose Conductor 02 Bolts, 250 mm spacing made of Aluminium alloy LM-6 complete with nuts,bolts & washers confirming to BIS:5561 8 Bolted type Tension fitting for Twin Moose conductor w/o Turn buckle for 132 KV Main Bus Bar suitable for 70 KN Disc Insulator string with 02 No. Tension Clamps made of Al. Alloy LM-6 Yoke Plate,D-Shackle,D-Socket etc. made from Forged Steel etc. 9 132 kV/220kV Suspension Insulator string and associated hardware fittings with drop clamp suitable for twin moose conductor. 10 20 MM GI U-Bolt of MS rod having thread on both side complete with washer and spring washer 04 nos. sample confirming to BIS:5561 11 132 KV P.T Clamp/Connector duly made of Aluminium Alloy (LM-6) Suitable forACSR Panther Conductor complete with bolts, nuts & Washers as per sample Conferming to BIS:5561. 12 132 KV Isolator Clamp/Connector duly made of Aluminium Alloy (LM-6) Suitable for Twin ACSR Panther Conductor complete with bolts, nuts & Washers as per sample . 13 132 KV IsolatorClamp/Connector duly made of Aluminium Alloy (LM-6) Suitable forACSR Moose Conductor complete with bolts, nuts & Washers as per sample . 14 132 KV C.B Clamp/Connector duly made of Aluminium Alloy (LM-6) Suitable forACSR Moose Conductor complete with bolts, nuts & Washers as per sample (Heptacare Make) 15 132 KV L.A Clamp/Connector duly made of Aluminium Alloy (LM-6) Suitable forACSR Moose Conductor complete with bolts, nuts & Washers as per sample Conferming to BIS:5561. 16 P.G Clamp ACSR Panther to Panther conductor 17 P.G Clamp ACSR Moose to Panther conductor 18 P.G Clamp ACSR Moose to Moose conductor 19 Supply and installationin Complete respect 2 Tonne Split ACfive star (Hitachi/O genral,Daikin or Eq make) with all Accessories and Stabliser( Not Less Than 05 KV Capacity) 20 132 KV P.T Clamp duly made of Aluminium Alloy (LM-6) Suitable forACSR Panther Conductor complete with bolts, nuts & Washers as per sample Conferming to BIS:5561. 21 132 KV Isolator Clamp duly made of Aluminium Alloy (LM-6) Suitable forACSR Moose Conductor complete with bolts, nuts & Washers as per sample . 22 132 KV C.B Clamp duly made of Aluminium Alloy (LM-6) Suitable for ACSR Moose Conductor complete with bolts, nuts & Washers as per sample (Heptacare Make) 23 132 KV L.A Clamp duly made of Aluminium Alloy (LM-6) Suitable forACSR Moose Conductor complete with bolts, nuts & Washers as per sample Conferming to BIS:5561. 24 5 KVDigital Insulation Tester (Megger) 25 Digital Multimeter (4 1/2 Digit) (Motwane Make or equivalent) 26 Clamp on meter (Digital) (0-300-600 A) 27 Work 28 Opening of existing jumpers of Twin/Single ACSR Panther/Zebra conductors ( 03 phase ) between 132KVMain Bus -Ito 04 No. Line Isolator,02 No. T/F,02 No. P.T,02 No.to Main Bus-I (01 Job for each Bay). 29 Opening of existing jumpers of Twin/Single ACSR Panther/Zebra conductors ( 03 phase ) between 132KV Main Bus -II to 04 No. Line Isolator,02 No. T/F,02 No. P.T,02 No.to Main Bus-II (01 Job for each bay). 30 De-Stringing & Dismantling of existing 132 KV Main Bus-Iof Single ACSR Zebra conductors after opening of Disc Insulator string & Tension Fitting from Gantry,lowering the Bus Bar conductors including shifting of the old conductor from switchyard to substation store and stacking/placing of same at suitable place at the stores (01 Job for each phase of each section of Bus Bar) 31 De-Stringing & Dismantling of existing 132 KV Main Bus -II of Single ACSR Zebra conductors after opening of Disc Insulator string & Tension Fitting from Gantry,lowering the Bus Bar conductors including shifting of the old conductor from switchyard to substation store and stacking/placing of same at suitable place at the stores (01 Job for each phase of each section of Bus Bar) 32 Laying & Re-Stringing of132 KV Main Bus -I of Twin ACSR Moose Conductors including Hoisting of Disc Insulator string & Tension Fitting etc. including shifting of the conductors/Materials from store to switchyard(01 Job for each phase of each section of Bus Bar) 33 Laying & Re-Stringing of132 KV Main Bus -IIof Twin ACSR Moose Conductors including Hoisting of Disc Insulator string & Tension Fitting etc. including shifting of the conductors/Materials from store to switchyard(01 Job for each phase of each section of Bus Bar) 34 Preparing the jumpers of Twin ACSR Panther/Moose conductors (03 phase) and connecting the same between newly laid 132 KV Main Bus Bar to 05 No. Line Isolator,03 No. T/F,02 No. P.T,01 No. Section Isolator bay to Main Bus -1(01 Job for each bayr). 35 Preparing the jumpers of Twin ACSR Panther/Moose conductors (03 phase) and connecting the same between newly laid 132 KV Main Bus Bar to 05 No. Line Isolator,03 No. T/F,02 No. P.T,01 No. Section Isolator bay to Main Bus-2 (01 Job for each bayr). 36 Jointing Section of 132 KV Main Bus by U shaped Twin Jumpers between adjacent bus Section with the help of suitable double P.G Clamp (01 Job for each bay) 37 Opening of existing jumpers of Twin/Single ACSR Panther/Zebra conductors ( 03 phase ) between Main Bus to 03 No. Line Isolator,03 No. CT,03 No. P.T,03 No. Bus Isolator bay to Main Bus (01 Job for each Jumper).for 132KV Bijnaur bay at 132KV S/S SGPGI 38 Opening of existing jumpers of Twin/Single ACSR Panther/Zebra conductors ( 03 phase ) between Main Bus to 03 No. Line Isolator,03 No. CT,03 No. P.T,03 No. Bus Isolator bay to Main Bus (01 Job for each Jumper).for 132KV Sarojini Nagr -2bay at 132KV S/S SGPGI 39 Preparing the jumpers of Twin ACSR Panther/Moose conductors (03 phase) and connecting the same between132 KV Main Bus Bar to 03 No. Line Isolator,03 No. CT,03 No. P.T,03 No. Bus Isolatorto Main Bus (01 Job for each Jumper)..for 132KV Bijnaur baty at 132KV S/S SGPGI 40 Preparing the jumpers of Twin ACSR Panther/Moose conductors (03 phase) and connecting the same between132 KV Main Bus Bar to 03 No. Line Isolator,03 No. CT,03 No. P.T,03 No. Bus Isolatorto Main Bus (01 Job for each Jumper)..for 132KV Sarojini Nagrbay-2 at 132KV S/S SGPGI 41 Dismantling of 145 KV 400-200/1A C.T 42 Errection of 145 KV 800-400-200/1A C.T 43 Dismantling of Old Protection Panel 44 Errection of New Protection Panel 45 Laying of following size control cables in Trench from C&R Pannel to various equipment. 46 2CX2.5Sqmm 47 4CX2.5Sqmm 48 6CX2.5Sqmm 49 Interconnection and Termination of Various Size control Cable between Feeder and C&R pannel/DPP to various equipments. 50 Dismantling of 120 KV Old LA 51 Erection of 120 KV New LA 52 Dismantling of 145 KV New P.T 53 Errection of 145 KV New P.T 54 Erection of 132 KV PT Junction Box . Last date of submission for this tender is 2025-09-15. This is a Substation tender in Lucknow, Uttar Pradesh

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

4 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in