🎉 Your free trial plan has started. Plan will expire in 0 days

State Bank Of India

lucknow, uttar pradesh

AOC value
₹16.21L
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

State Bank Of India has published Bids Are invited for Vrf Or Vrv Air Conditioning System At State Bank Of India Rbo 2 Lucknow West 20 Hp Outdoor Vrv Or Vrf - Supply Of Air Cooled 20 Hp Outdoor Units Suitable For Cooling And Heating. Refer Technical Specification And Boq For Details. , 4 Way 2.0 Tr Vrf Cassette Indoor - Supply Of 5 Ceiling Suspended 4-Way Vrf/Vrv Cassette Type 2.0 Tr Indoor Unit In In False Ceiling With Full Function Wireless Remote And Auto Restart Feature. Refer Technical Specification And Boq For Details. , 4 Way 1.3 Tr Vrf Cassette Indoor - Supply Of Ceiling Suspended 4-Way Vrf/Vrv Cassette Type 1.3 Tr Indoor Unit In Recessed Manner In False Ceiling With Full Function Wireless Remote And Auto Restart Feature. Refer Technical Specification And Boq For Details. , Y Joints - Supply Installation Of Joints , Installation Of 20 Hp Vrv Or Vrf Outdoor - Installation, Testing And Commissioning Of Vrf 20Hp Outdoor With Gas Etc. Including Making Good Of Damages Complete In All Respects. , Installation Of 2.0 Casssette Vrf Indoor - Installation, Testing And Commissioning Of Vrv/Vrf Cassette 2.0 Tr Indoor With Gas Etc. Including Making Good Of Damages Complete In All Respects. , Installation Of 1.3 Casssette Vrf Indoor - Installation, Testing And Commissioning Of Vrv/Vrf Cassette 1.3 Tr Indoor With Gas Etc. Including Making Good Of Damages Complete In All Respects. , Commisioning Of Complete Vrf System - Commisioning Of Complete Vrf System With All Machines , Refrigerant Piping 28.6 Mm - Supply, Installation, Testing And Commissioning Of Interconnecting 28.6 Mm Refrigerant Pipe Work With (19Mm/13 Mm Thick) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All Piping Inside The Room Shall Be Properly Supported. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification And Boq For Details. , Refrigerant Piping 22.2 Mm - Supply, Installation, Testing And Commissioning Of Interconnecting 22.2 Mm Refrigerant Pipe Work With (19Mm/13 Mm Thick) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All Piping Inside The Room Shall Be Properly Supported. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification And Boq For Details. , Refrigerant Piping 19.1 Mm - Supply, Installation, Testing And Commissioning Of Interconnecting 19.1 Mm Refrigerant Pipe Work With (19Mm/13 Mm Thick) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All Piping Inside The Room Shall Be Properly Supported. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification And Boq For Details. , Refrigerant Piping 15.9 Mm - Supply, Installation, Testing And Commissioning Of Interconnecting 15.9 Mm Refrigerant Pipe Work With (19Mm/13 Mm Thick) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All Piping Inside The Room Shall Be Properly Supported. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification And Boq For Details. , Refrigerant Piping 9.5 Mm - Supply, Installation, Testing And Commissioning Of Interconnecting 9.5 Mm Refrigerant Pipe Work With (19Mm/13 Mm Thick) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All Piping Inside The Room Shall Be Properly Supported. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification And Boq For Details. , Drain Pipe 32 Mm - Supply, Installation, Testing And Commissioning Of Pvc 32 Mm Water Pipe With 6 Mm Thik Nitrile Rubber Insulation And Accessories And Taking Care To Prevent Leakages, For Water Drainage In Concealed Manner Either On Wall Or Under Floor Including Making Good Of Damages. Refer Technical Specification And Boq For Details. , Drain Pipe 25 Mm - Supply, Installation, Testing And Commissioning Of Pvc 25 Mm Water Pipe With 6 Mm Thik Nitrile Rubber Insulation And Accessories And Taking Care To Prevent Leakages, For Water Drainage In Concealed Manner Either On Wall Or Under Floor Including Making Good Of Damages. Refer Technical Specification And Boq For Details. , Control And Transmission Wiring - Supply & Fixing Of Control Cum Transmission Wiring Of 3 Core X 1.5 Sqmm Copper In Suitable Conduits Between Indoor And Out Door Unit. Refer Technical Specification And Boq For Details. , Ms Sloted Angle For Pipe Paying , Outdoor Stand For Vrv Or Vrf 20 Hp - Supply And Installation Of Robust Ms Angle, Ms Flat Fabricated Floor/ Wall Mounting Stand Suitable For 20 Hp Vrf Outdoor Units. Refer Technical Specification And Boq For Details. , Sitc Of 5 Star 3 Ton Cassette A C , Copper Pipe Refrigerant Piping For 1.5 Or 2 Tr - Copper Pipe Refrigerant Piping For 2 Tr , Interconnecting Standard Wire Cable , Drain Pipe , Ms Stand Total Quantity : 765. Last date of submission for this tender is 2026-06-06. This is a Air Conditioner tender in Lucknow, Uttar Pradesh

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in