Rajkiya Ayurvigyan Sansthan Greater
- AOC value
- Refer Docs
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Authority
- Rajkiya Ayurvigyan Sansthan Greater
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Rajkiya Ayurvigyan Sansthan Greater has published E-Tender For Roof Treatment Work At Hospital Block For Government Institute Of Medical Sciences Greater Noida E-Tender For Roof Treatment Work At Hospital Block For Government Institute Of Medical Sciences Greater Noida , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. , Demolishing Mud Phaska In Terracing And Disposal Of Material Within 50 Metres Lead. , Disposal Of Moorum / Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Material By Mechanical Transport Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground For Lead Upto 10 Km For All Lifts, Complete As Per Directions Of Engineer-In-Charge. Note - Item To Be Applicable In Urban Areas Having Directions For Restricted Hours For Movement / Plying Of Load Carrying Motor Vehicle Of 3.5 Cum Or More. , Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq. Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Directions Of Engineer-In-Charge. , With Cement Mortar 1:4 ( 1Cement: 4 Coarse Sand ) , Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: , Applying A Slurry Coat Of Neat Cement Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compoundonforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rcc Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. , Laying Brick Bats With Mortar Using Broken Bricks / Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 ( 1 Cement : 5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 ( 1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. , After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge. , Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 ( 1 Cement :4 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. , The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test. All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : , With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. Note :- Cost Of Brick Bats Will Be Zero ( Free Of Cost ) & Same Will Be Used From Above Item No-2 , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Up To Any Pitch, Including Fixing With Polymer Coated J Or L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain / Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Violet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Conform To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified. , 2 Mm Thick Corrugated ( 2.5 Or 4.2 Or 6 ) Or Step-Down ( 2 Or 3 Or 6 ) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10 Mm And Down Gauge ) , Including Finishing With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) As Per Standard Design : , In 75X75 Mm Deep Chase , Providingand Applying Fibre Reinforced Elastomeric Liquid Water Proofing Membrane With Resilient Acrylic Polymers Having Sun Reflectivity Index ( Sri ) Of 105 On Top Of Concrete Roof In Three Coats @10.76 Litre / 10 Sqm. One Coat Of Self-Priming Of Elastomeric Waterproofing Liquid ( Dilution With Water In The Ratio Of 3:1 ) And Two Coats Of Undiluted Elastomeric Waterproofing Liquid ( Dry Film Thickness Of Complete Application / System Not Less Than 500 Microns ) . The Operation Shall Be Carried Out After Scrapping And Properly Cleaning The Surface To Remove Loose Particles With Wire Brushes, Complete In. Last date of submission for this tender is 2021-10-13. This is a Passenger Lift tender in Greater Noida, Uttar Pradesh
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
3 issued- Tender Document 1pdfPDF document
- Tender Document 2pdfPDF document
- Tender Document 3htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free