Purvanchal Vidyut Vitaran Nigam Limited
- AOC value
- Refer Docs
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Purvanchal Vidyut Vitaran Nigam Limited has published Tender For Electrical Work - Repairing Of Damaged / Rusted Round Poles, Line Maintenance Works And Repairing Of T / F Plinth Etc. In Under Edsd-Myorpur Jurisdictionof Ee Edd Pipari. 1 Following Works Are To Be Carried Out Under The Jurisdiction Of Ee Edd Robertsganj 2 Repairing Of Damaged / Rusted Round Poles, Firstly By Caging With Cement Concrete Mixture Of Ratio 1:4:8 And M.S. Rod Of 5 / 8” Dia 2.5 Mtr. Long 2 Nos. And Then By Welding 4 Nos. 50X6 Mm Angle Iron As Per Site Requirement At An Interval Of 90 Degree Along With Making Plinth Around The Pole By Providing All Labour, Material And T & P. 3 Erection, Grouting, Plinthing & Earthings Of 8.5 / 9 / 11 Mtr Long Stp In Place Of Damaged / Unrepaired Stp Of 11 Kv / L.T. Line With Fixing Of Necessary Clamps And Other Accessories Like One No. Cross Arm, One No. Guarding Angle, Grouting Ratio 1:4:8, Cement, Stone, Grit & Coarse Sand, Plinthing Of Support Of Size 0.4X0.45X0.3 Mtr. With Cement Sand & Bricks Blast In Ratio 1:4:8 And 12 Mm Thick Plastering Around The Plinth In Ratio 1:2:4 With 12 Mm Thickness Curing Of Plinth Should Be Done Properly ( Grouting & Plinthing Material Will Be Arranged By The Contractor ) . 4 Grouting Of 8.5 / 9 / 11 Mtr. Long Damaged / Unrepaired Single Support Stp With Ratio 1:4:8, Cement, Stone, Grit & Coarse Sand, Plinthing Of Support Of Size 0.4X0.45X0.3 Mtr. With Cement Sand & Bricks Blast In Ratio 1:4:8 And 12 Mm Thick Plastering Around The Plinth In Ratio 1:2:4 With 12 Mm Thickness Curing Of Plinth Should Be Done Properly ( Grouting & Plinthing Material Will Be Arranged By The Contractor ) . 5 Dismantling Of Old Lt / Ht Supports 8.5 / 9 / 11 Mtr Long Stp Along With All Accessories On Pole Such As Pin Insulator, Disc Insulator / Fitting, Cross Arms, M.S. Channels Etc. And Carriage Of Poles Etc. From Site To Store Robertsganj / Power House . 6 Erection, Grouting & Earthings Of 8.5 Mtr Long Pcc Pole In Place Of Damaged / Unrepaired Pcc Pole Of 11 Kv / L.T. Line With Fixing Of Necessary Clamps And Other Accessories Like One No. Cross Arm, One No. Guarding Angle, Grouting Ratio 1:4:8, Cement, Stone, Grit & Coarse Sand. ( Grouting & Plinthing Material Will Be Arranged By The Contractor ) . 7 Grouting Of 8.5 Mtr. Long Damaged / Unrepaired Single Support Pcc Pole With Ratio 1:4:8, Cement, Stone, Grit & Coarse Sand Should Be Done Properly ( Grouting & Plinthing Material Will Be Arranged By The Contractor ) . 8 Line Maintenance Works. 9 Opening Of Binding On Each Pole Of Loose L.T. Line And Tightening Of Loose Conductor On Insulator Complete In All Respect. 10 Opening Of Binding On Each Pole Of 11 Kv Line And Tightening Of Loose 11 Kv Line Conductor On Insulator Complete In All Respect Of 33 Kv Line. 11 Replacing Damaged Guarding Of Ht / Lt Lines By Making New Guard For Maintaining Proper Gap Between Phase And Ground. 12 Fixing Stay Insulator In Stay Wire Where Stay Insulator Not Fitted Earlier / Damaged 13 Providing And Fixing Of Strips / Spacer In Lt Line For Maintaining Proper Gap. 14 Cutting Of Tree Branches All Along The Route Of 11 Kv, Lt O / H Line, Which May Obstruct The Line. 15 Small Tree Branches. 16 Big Strems Of Tree 17 Repairing Of T / F Plinth 18 Carriage Of Transformer Trolley / Tractor Trolley, Opening Of Ht & Lt Connection From Existing T / F Shifting Of 11 / .4 Kv 630 / 400 / 250 Kva T / F From Existing Damaged Plinth To Mobile Trolley / Tractor Trolley Re-Energize The T / F On Mobile Trolley / Tractor Trolley After Making All Ht / Lt Connections. Repairing Of Damaged T / F Plinth Of Size 1.5X1.5X1.25 M Suitable For 630 / 400 / 250 Kva Transformer With The Mixture Of 1:4 Cement Coarse Sand, And Complete Civil Material With Fixing Of Two Nos. Ms Channel Of Size 100X50 Mm 1.5 M Length On The Top. Opening Of Ht & Lt Connections Of T / F Installed At Mobile Trolly / Tractor Trolley & Re-Shifting Of T / F On Repaired Plinth & Making All Ht & Lt Connection & Re-Energize The T / F As Per Instrucion Of Sdo / Je In-Charge.. Last date of submission for this tender is 2023-06-26. This is a Electrical Maintenance tender in Sonbhadra, Uttar Pradesh
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
4 issued- Tender Document 1htmlHTML document
- Tender Document 2xlsxXLSX document
- Tender Document 3pdfPDF document
- Tender Document 4pdfPDF document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free