Dakshinanchal Vidyut Vitran Nigam Limited
- AOC value
- Refer Docs
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Dakshinanchal Vidyut Vitran Nigam Limited has published Tender For Work Of Maintenance Of Ht/Lt Lines In The Area Of Edd-Jalesar Under Edc, Etah. - Safe carriage of 8.5 mtr. long PCC pole from store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 60 Km. including loading & unloading at both ends. 2 Safe carriage of11/13 mtr STPfrom store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 60 Km. including loading & unloading at both ends. 3 Safe carriage of9 mtr STPfrom store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 60 Km. including loading & unloading at both ends. 4 Safe carriage of line material from store center Etah/nearest substation to pit site in distance range 0 to 60 Km. including loading & unloading at both ends. 5 Opening of binding & removal of following conductor with 33 KV/HT/LT line from broken PCC poles/rails/ STP and stacking at safer place. 6 1- Dog/ Raccoon/ Rabbit conductor 7 2- AAAC/ACSR weasel conductor/ GI wire. 8 3- ABC 3X95+1X35+1X16/3x50mm 9 4- ABC 3x120+1x70+1x16 10 Erection of 8.5 mtr. long PCC poles as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes 11 Erection of 9 mtr. STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes 12 Errection of 11/13 mtr.STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes 13 Errection of 8.5 mtr. long PCC poles as Double Pole/ section pole including drilling,cutting etc. andfixing of all accessories etc. complete. 14 Errection of 11mtr. STP as Double Pole/ section pole including drilling,cutting etc. andfixing of all accessories etc. complete. 15 Laying stringing & sagging of 3 phase 3 wire 33/HT/LT line with following condudctor including binding & nozzling. 16 1- Dog/ Raccoon/ Rabbit conductor 17 2- AAAC/ACSR weasel conductor/ GI wire. 18 3-ABC 3*95 mm/3*50 mm 19 4- ABC 3x120+1x70+1x16 20 Straightening of tilted PCC poles/ST P/Railsingle support of HT/LT line after opening of nuzzling, digging of pit applying anti direction force for making of proper alignment of line. 21 Straightening of tilted D/P after opening of connection applying anti direction force, digging of dug for proper alignment of line including reconnection etc. complete. 22 Opening of HT/LT connections & lowering of followingT/F from D/P/Plinth and shifting up to in safer place. 23 1- 25/63 KVA T/F 24 2- 100 KVA T/F 25 Dismanteling of old/damage STP/RS Joistof HT/LT line andcarriage to store centre Etah 26 Re-sagging of loose 33/HT/LT conductor after opening, binding, nozzling etc. 27 1- Dog/ Raccoon/ Rabbit conductor 28 2- AAAC/ACSR weasel conductor/ GI wire. 29 3- ABC 3X120+1X70+1X16 30 4-ABC 3X95+1X35+1X16 31 5-ABC 3X50+1X35+1X16 32 Replacement of following broken/damaged/missing accessories by new accessories including opening of the same and refixing. 33 1-11 KV cross arms V type 34 2-11 KV pin insulator 35 3-11 KV pin with nut 36 4-11 KV Disc insulator 37 5-Cross Arms holding clamps 38 6-F Clamps 39 7-LT shackle insulator 40 8-33 KV cross arm. 41 9-33 KV pin with nut 42 10- 33 KV pin insulator 43 Retightening of Stay rod. Etc. complete. 44 Providingfixing of stay rod with nuzzling etc. complete. 45 Consumeable like nut & bolts of off size, cleaning chemical/material, cleaning clothes, insulating tape etc. will be required to complete the work shall be at contractor cost. 46 Earthing of PCC/RS Joist/STP as per RESPO norms. 47 Carriage of old material from pit site to JE store/store center, Etah in distance range 0 to 10 km including loading & unloading and proper stacking. 48 Mounting of Following Transformers on double pole/Plinth including making of the connection etc complete. 49 1- 25/63 KVA T/F 50 2- 100 KVA T/F 51 Chopping of tree branches 52 Repairing/ Resagging / new guarding of HT lines with GI wire as per RESPO norms . Last date of submission for this tender is 2025-08-29. This is a Overhead Line tender in Etah, Uttar Pradesh
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
3 issued- Tender Document 1htmlHTML document
- Tender Document 2xlsxXLSX document
- Tender Document 3pdfPDF document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free