🎉 Your free trial plan has started. Plan will expire in 0 days

Dakshinanchal Vidyut Vitran Nigam Limited

etah, uttar pradesh

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Dakshinanchal Vidyut Vitran Nigam Limited has published The Work Of Increasing Capacity Of Distribution Tf/Change The Cable/Strengthing Of Line/Other In The Eudd, Etah Under The Jurisdiction Of Edc Etah. - Supply of Material by the Contractor as per relevant ISS :- 2 Stone Pad (300x300x75 mm) 3 Danger Board with Clamp and N&B 4 Barbed wire including Jumper 5 MS Top Channel 125x65x2240 mm 6 Nut Bolt & Washer off sizes 7 MS T/F Base Angle with Clamp and N&B (75x75x6x2028 mm.) 8 Holding Clamp for Top and Dropper channel with Nut & Bolts 9 Al. Lug Long Barrel off size 10 Clamp for LT T off channel with nut & bolts 11 Copper L-Piece 50x225x10 sq. mm 12 11 KV Fuse Set 13 11 KV Cable Jointing Kit O/D 3x70 sq. mm 14 F Bracket with N&B 15 M.S. T off Channel (125x65x1300 mm) 16 LT Clamp with N&B 17 3-Phase D.O. Fuse Set 18 D.P. Clamp 19 M.S. Dropper Channel (100x50x2028 mm) 20 Safe Carriage of following material from Electricity Store Center Etah to pit site of work from the Kaccha & Pakka Road including loading & unloading at the respective ends including the cost of arrangement of labour, T&P etc. which required for poper completion of work (Distance 0 to 60 kms.) 21 OC/EF and Differencial Protection Relay 22 11 KV TPMO with Polymer Insulator 23 Stay Set Complete 24 Earthing Rod Complete 25 11 KV V Type X Arm 65x65x6 mm. 26 11 KV Pin Insulator with Pin 27 11 KV Disc with fitting 28 LT XLPE Cable Al. 3.5x150/70 sq. mm 29 LT XLPE Cable Al. 3.5x400 sq.mm. 30 LT XLPE Cable 1x240 sqmm. 31 LT XLPE Cable Al. 1x120 sqmm. 32 11 KV XLPE Cable 3x70 sq. mm 33 PCC Pole 8.5 mtr. Long 34 S.T Pole 11 mtr. Long 35 63 KVA T/F 11/0.4 KV 36 100 KVA T/F 11/0.4 KV 37 250 KVA T/F 11/0.4 KV 38 ACSR Weasel conductor 39 Erection of Material 40 Erection of single support including complete H.T/L.T fittings PCC Pole 8.5 Mtrincluding Grouting & Muffing of pole per DVVNL/RESPO norms. 41 Erection of Single Support including complete H.T/L.T fittings etc. S.T. Pole 11 Mtr SP-55 including Grouting & Muffing of pole per DVVNL/RESPO norms. 42 Erection of Double Support including complete H.T/L.T fittings etc. S.T. Pole 11 Mtr SP-55 including Grouting & Muffing of pole per DVVNL/RESPO norms. 43 Installation of 11 KV TPMO with polymar Insulator 44 Erection of stay set complete including the work of nuzzling etc. 45 Erection of Earthing rod complete 46 Laying sagging stringing, binding and jumpering ACSR Weasel conductor 47 Installation and commissioning of OC/EF and Differencial Protection Relay 48 Laying & Termination of LT XLPE Cable Al. 3.5x150/70 sq. mm 49 Laying & Termination of LT XLPE Cable 1x240 sqmm. 50 Laying & Termination of LT XLPE Cable Al.3.5x400 sqmm. 51 Laying & Termination of LT XLPE Cable Al. 1x120 sqmm. 52 Laying and Termination of 11 KV XLPE Cable 3x70 sq. mm 53 Erection/Fixing of Copper L-Piece 50x225x10 sq. mm 54 Installation of 3-Phase D.O. Fuse Set 55 Installation of 11 KV Fuse Set 56 Installation of Danger Board 57 Installation Barbed wire including jumper 58 Installation of 63 KVAT/F 11/0.4 KV New at sitein all respect 59 Installation of 100 KVAT/F 11/0.4 KV New at sitein all respect 60 Installation of 250 KVAT/F 11/0.4 KV New at sitein all respect 61 Installation of 11 KV Cable Jointing Kit O/D 3x70 sq. mm 62 Construction of 250 KVA T/F plinth for size 2x2x1.5 M with the help of first class brick and masonry in the ratio 1:4 cement & sand coarse. Filling the structure completely as per norms with RCC top 1:2:4 cement, sand coarse and stone grit with MS Bar and MS channel for resting transformer wheel (100x50x6mm) and plaster. All material shall be provided by the contractor. 63 Providing and erection of welded wire mesh fencing around transformer plinth with MS Angle of size 40x40x6 mm length and 1.20 mtrs height. Such panels shall be supported on MS angle from of size 40x40x6 mm having 04 nos corner supports of height 1.65 mtrs including extended legs for grouting which will be used as a door for entry of the personnel or removal/shifting of transformer with welded hinges, sliding belt etc for lockingarrangement as per drawing and specifications. The fencing will be painted in the green colour synthetic enamel paint after painting with one coat of red oxide primer. The rates should be inclusive of all materials required for completion of above work. (Length of each fencing approx. 11 mtrs) with T& P labour etc. All material shall be provided by the contractor. 64 Pipe earthingup to water level of 250 KVA medium Power Transformers (Body & Nutral).All material shall be provided by the contractor. 65 Charges for Dismantling Work:- Work includes dismantling from site and cartage of same materails from site/location to central store as per instruction of JE/SDO/EE concerned. 66 LT XLPE Cable 3.5x150/70 sq. mm (Scrap) 67 ACSR Dog Conductor (Reuseable) 68 11 KV AB Cable 1x120 sq. mm 69 11/0.4 KV 100 KVA T/F old . Last date of submission for this tender is 2024-11-21. This is a Cable Laying tender in Etah, Uttar Pradesh

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in