🎉 Your free trial plan has started. Plan will expire in 0 days

Southern Railway

madurai, tamil nadu

AOC value
₹45.59L
AOC date
15 Sep
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 15 Sep 26AOC date

Important info

Result ID
Refer Docs
Award of contract
15/09/2026
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Southern Railway has published Supply Of fabricated and galvanized steel structure. , bridge mast of 10.5mtr long of fabricated and galvanized b series steel structure (b- 200) wit h base plate of size 700 x700 x25 mm =6 nos. the mast confirming to rdsos drawing no. eti/c/0071 rev-e or latest using fabricators own steel and zinc, steel confirming to is: 2062/2011, gr. e250(fe-410 w), quality a & is: 808/1989 and zinc to is: 209/1992 and rdso specification no. eti/ohe/13 (4/84) with a and c slip nos 1,2 and 3 for galvanization or latest .( each b-200 bridge mast of 10.5m length with base plate a pproximate weight of 784.104 kgs. mc 200x75 mm shall be used. the overall approximate total weight of 6 nos of bridge mast is- 4.7 mt. each mast should have gi holding down bolt of size 25mm dia and 500 mm l ength threaded portion 180mm with washers and nuts confirming to is 2062-92 grade a are included in th e scope of supply.the weight indicated is block weight as per the approved drawing, and the final weight af ter galvanization at 1000 grams per square meter will proportionally vary, resulting in a marginal increase. this variation in weight will be accommodated and accounted for by the consignee based on the inspection certificate (ic) issued by the third-party inspection (tpi) agency. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , fabricated and galvanized steel structures (ttc 8.0 m boom) are to be manufactured as per rdso drawing no. eti/c/0009/69, sheets 2, 3 & 5, rev-c or latest, using the fabricators own steel and zinc. the steel shall conform to is: 2062:2011, is:800, grade e250 (fe 410w), quality a, and is:808/1989, while the zinc used for galvanization shall conform to is:209/1992 and rdso specification no. eti/ohe/13 (4/84) with addendum and corrigendum slip nos. 1, 2 & 3 or latest. one complete set of ttc assembly consists of ttu (10.135 meter long) 1 no. weighing 616.635 kg, ttk (1 & 2) 1 set weighing 87.668 kg, and ttb (8.0 me ter) 1 no. weighing 362.369 kg, resulting in a total weight of 1066.672 kg (i.e., approximately 1.067 mt). t otal set- 3 set. the total approximate weight for 3 sets of ttc assembly comes to 3.201 mt. in addition, 1 n os. of ttu (10.135 meter long), each weighing 616.635 kg (0.62 mt) in a total weight of approximately 0.62 mt. the overall approximate total weight of 3 ttc assembly sets and 1 ttu is 3.816 mt. the weight indicat ed is block weight as per the approved drawing, and the final weight after galvanization at 1000 grams per square meter will proportionally vary, resulting in a marginal increase. this variation in weight will be acco mmodated and accounted for by the consignee based on the inspection certificate (ic) issued by the third- party inspection (tpi) agency. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , fabricated and galvanized steel structures (ttc 8.0 m boom) are to be manufactured as per rdso drawing no. eti/c/0009/69, sheets 2, 3 & 5, rev-c or latest, using the fabricators own steel and zinc. the steel shall conform to is: 2062:2011, is:800, grade e250 (fe 410w), quality a, and is:808/1989, while the zinc used for galvanization shall conform to is:209/1992 and rdso specification no. eti/ohe/13 (4/84) with addendum and corrigendum slip nos. 1, 2 & 3 or latest. one complete set of ttc assembly consists of ttu (10.135 meter long) 1 no. weighing 616.635 kg, ttk (1 & 2) 1 set weighing 87.668 kg, and ttb (8.0 me ter) 1 no. weighing 362.369 kg, resulting in a total weight of 1066.672 kg (i.e., approximately 1.067 mt). t otal set- 4 set. the total approximate weight for 4 sets of ttc assembly comes to 4.268 mt. in addition, 7 n os. of ttu (10.135 meter long), each weighing 616.635 kg (0.62 mt) in a total weight of approximately 4.31 6 mt. the overall approximate total weight of 4 ttc assembly sets and 7 ttus is 8.584 mt. the weight indi cated is block weight as per the approved drawing, and the final weight after galvanization at 1000 grams per square meter will proportionally vary, resulting in a marginal increase. this variation in weight will be a ccommodated and accounted for by the consignee based on the inspection certificate (ic) issued by the thi rd-party inspection (tpi) agency. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , fabricated and galvanized steel structures (ttc 8.0 m boom) are to be manufactured as per rdso drawing no. eti/c/0009/69, sheets 2, 3 & 5, rev-c or latest, using the fabricators own steel and zinc. the steel shall conform to is: 2062:2011, is:800, grade e250 (fe 410w), quality a, and is:808/1989, while the zinc used for galvanization shall conform to is:209/1992 and rdso specification no. eti/ohe/13 (4/84) with addendum and corrigendum slip nos. 1, 2 & 3 or latest. one complete set of ttc assembly consists of ttu (10.135 meter long) 1 no. weighing 616.635 kg, ttk (1 & 2) 1 set weighing 87.668 kg, and ttb (8.0 me ter) 1 no. weighing 362.369 kg, resulting in a total weight of 1066.672 kg (i.e., approximately 1.067 mt). t otal set- 1 set. the total approximate weight for 1 set of ttc assembly comes to 1.067 mt. the weight indic ated is block weight as per the approved drawing, and the final weight after galvanization at 1000 grams p er square meter will proportionally vary, resulting in a marginal increase. this variation in weight will be ac commodated and accounted for by the consignee based on the inspection certificate (ic) issued by the thir d-party inspection (tpi) agency. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , bridge mast of 10.5mtr long of fabricated and galvanized b series steel structure (b- 200) wit h base plate of size 700 x700 x25 mm =2 nos. the mast confirming to rdsos drawing no. eti/c/0071 rev-e or latest using fabricators own steel and zinc, steel confirming to is: 2062/2011, gr. e250(fe-410 w), quality a & is: 808/1989 and zinc to is: 209/1992 and rdso specification no. eti/ohe/13 (4/84) with a and c slip nos 1,2 and 3 for galvanization or latest (each b-200 bridge mast of 10.5m length with base plate ap proximate weight of 784.104 kgs. mc 200x75 mm shall be used. the overall approximate total weight of 2 nos of bridge mast is- 1.6 mt. each mast should have gi holding down bolt of size 25mm dia and 900 mm l ength threaded portion 150mm with washers and nuts confirming to is 2062-92 grade a are included in th e scope of supply.the weight indicated is block weight as per the approved drawing, and the final weight af ter galvanization at 1000 grams per square meter will proportionally vary, resulting in a marginal increase. this variation in weight will be accommodated and accounted for by the consignee based on the inspection certificate (ic) issued by the third-party inspection (tpi) agency. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , fabricated and galvanized steel structures (ttc 8.0 m boom) are to be manufactured as per rdso drawing no. eti/c/0009/69, sheets 2, 3 & 5, rev-c or latest, using the fabricators own steel and zinc. the steel shall conform to is: 2062:2011, is:800, grade e250 (fe 410w), quality a, and is:808/1989, while the zinc used for galvanization shall conform to is:209/1992 and rdso specification no. eti/ohe/13 (4/84) with addendum and corrigendum slip nos. 1, 2 & 3 or latest. one complete set of ttc assembly consists of ttu (10.135 meter long) 1 no. weighing 616.635 kg, ttk (1 & 2) 1 set weighing 87.668 kg, and ttb (8.0 me ter) 1 no. weighing 362.369 kg, resulting in a total weight of 1066.672 kg (i.e., approximately 1.067 mt). t otal set- 1 set. the total approximate weight for 1 set of ttc assembly comes to 1.067 mt. in addition, 1 n os. of ttu (10.135 meter long), each weighing 616.635 kg (0.62 mt) in a total weight of approximately 0.62 mt. the overall approximate total weight of 1 ttc assembly sets and 1 ttu is 1.687 mt. the weight indicat ed is block weight as per the approved drawing, and the final weight after galvanization at 1000 grams per square meter will proportionally vary, resulting in a marginal increase. this variation in weight will be acco mmodated and accounted for by the consignee based on the inspection certificate (ic) issued by the third- party inspection (tpi) agency. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , fabricated and galvanized steel structures (ttc 8.0 m boom) are to be manufactured as per rdso drawing no. eti/c/0009/69, sheets 2, 3 & 5, rev-c or latest, using the fabricators own steel and zinc. the steel shall conform to is: 2062:2011, is:800, grade e250 (fe 410w), quality a, and is:808/1989, while the zinc used for galvanization shall conform to is:209/1992 and rdso specification no. eti/ohe/13 (4/84) with addendum and corrigendum slip nos. 1, 2 & 3 or latest. one complete set of ttc assembly consists of ttu (10.135 meter long) 1 no. weighing 616.635 kg, ttk (1 & 2) 1 set weighing 87.668 kg, and ttb (8.0 me ter) 1 no. weighing 362.369 kg, resulting in a total weight of 1066.672 kg (i.e., approximately 1.067 mt) to tal set- 5 set. the total approximate weight for 5 set of ttc assembly comes to 5.34 mt. in addition, 11 nos . of ttu (10.135 meter long), each weighing 616.635 kg (0.62 mt) in a total weight of approximately 6.82 m t. the overall approximate total weight of 5 ttc assembly sets and 11 ttu is 12.2 mt. the weight indicate d is block weight as per the approved drawing, and the final weight after galvanization at 1000 grams per s quare meter will proportionally vary, resulting in a marginal increase. this variation in weight will be accom modated and accounted for by the consignee based on the inspection certificate (ic) issued by the third-pa rty inspection (tpi) agency. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , fabricated and galvanized steel structures (ttc 8.0 m boom) are to be manufactured as per rdso drawing no. eti/c/0009/69, sheets 2, 3 & 5, rev-c or latest, using the fabricators own steel and zinc. the steel shall conform to is: 2062:2011, is:800, grade e250 (fe 410w), quality a, and is:808/1989, while the zinc used for galvanization shall conform to is:209/1992 and rdso specification no. eti/ohe/13 (4/84) with addendum and corrigendum slip nos. 1, 2 & 3 or latest. one complete set of ttc assembly consists of ttu (10.135 meter long) 1 no. weighing 616.635 kg, ttk (1 & 2) 1 set weighing 87.668 kg, and ttb (8.0 me ter) 1 no. weighing 362.369 kg, resulting in a total weight of 1066.672 kg (i.e., approximately 1.067 mt). t otal set- 1 set. the total approximate weight for 1 set of ttc assembly comes to 1.067 mt. in addition, 1 n os. of ttu (10.135 meter long), each weighing 616.635 kg (0.62 mt) in a total weight of approximately 0.62 mt. the overall approximate total weight of 1 ttc assembly sets and 1 ttu is 1.687 mt. the weight indicat ed is block weight as per the approved drawing, and the final weight after galvanization at 1000 grams per square meter will proportionally vary, resulting in a marginal increase. this variation in weight will be acco mmodated and accounted for by the consignee based on the inspection certificate (ic) issued by the third- party inspection (tpi) agency. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , fabricated and galavanised b series steel mast as per rdso spec no. eti/psi/37 o r latest for galavanization using fabricators own steel and zinc steel confirming to is: 20 62/2011, is : 800 , gr e.250 (fe-410w) quality a and is 808 / 1989 and zinc to is209/1992 lt supply t ransformer mast t-150 (38.18 kg/m) 9.30 meters long with approximate weight of 355.074 kgs qty-6 nos. the overall approximate total weight of 6 nos t-150 mast is 2.1 mt.the weight indicated is block weight a s per the approved drawing, and the final weight after galvanization at 1000 grams per square meter will p roportionally vary, resulting in a marginal increase. this variation in weight will be accommodated and acco unted for by the consignee based on the inspection certificate (ic) issued by the third-party inspection (tpi ) agency. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , fabricated and galvanized steel structures (ttc 8.0 m boom) are to be manufactured as per rdso drawing no. eti/c/0009/69, sheets 2, 3 & 5, rev-c or latest, using the fabricators own steel and zinc. the steel shall conform to is: 2062:2011, is:800, grade e250 (fe 410w), quality a, and is:808/1989, while the zinc used for galvanization shall conform to is:209/1992 and rdso specification no. eti/ohe/13 (4/84) with addendum and corrigendum slip nos. 1, 2 & 3 or latest. one complete set of ttc assembly consists of ttu (10.135 meter long) 1 no. weighing 616.635 kg, ttk (1 & 2) 1 set weighing 87.668 kg, and ttb (8.0 me ter) 1 no. weighing 362.369 kg, resulting in a total weight of 1066.672 kg (i.e., approximately 1.067 mt). t otal set- 1 set. the total approximate weight for 1 set of ttc assembly comes to 1.067 mt. in addition, 1 n os. of ttu (10.135 meter long), each weighing 616.635 kg (0.62 mt) in a total weight of approximately 0.62 mt. the overall approximate total weight of 1 ttc assembly sets and 1 ttus is 1.68 mt. the weight indicat ed is block weight as per the approved drawing, and the final weight after galvanization at 1000 grams per square meter will proportionally vary, resulting in a marginal increase. this variation in weight will be acco mmodated and accounted for by the consignee based on the inspection certificate (ic) issued by the third- party inspection (tpi) agency. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , fabricated and galavanised small part steel as per drg no.eti/c/0076 for galav anization using fabricators own steel and zinc steel confirming to is: 2062/2011, is: 800 gr e .250 (fe-410w) quality a and is 808 / 1989 and zinc to is209/1992 6x6 bfb drop arm (2.875 mtr lo ng, ri no. 0076-1) with aproximate weight of 121.76 kgs qty: 2 nos (total weight: 243 kgs) (i.e., approximately 0.24 mt) [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]. Last date of submission for this tender is 2026-03-24. This is a Railway Ancillaries tender in Madurai, Tamil Nadu

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in