🎉 Your free trial plan has started. Plan will expire in 0 days

Department Of Higher Education

Laboratory Equipment And Supplies
coimbatore, tamil nadu
AOC Value₹1.65 Lac
AOC Date21 Nov 2025
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
21/11/2025
Authority
Department Of Higher Education
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
Bidding URL
Tender
Bidder Details

AOC Description

Department Of Higher Education has published Equipment , Purchase Of Equipment:Portable Electrochemicl Device , Portable Electrochemical Device: Potentiostat With Electrochemical Impedance Spectroscopy (Eis), Full Dc-Potential Range: - 2 V To +2 V Dynamic Dc-Potential Range: 2.2 V, Compliance Voltage: -2.0 To +2.0 V Maximum Current: ± 5 Ma, Max. Data Acquisition Rate: 1000 Datapoints/S, Should Supports Eis Potentiostat - Channels: 1 Channel (1X We, 1X Re, 1X Ce),Applied Dc-Potential Resolution: 540 ?V Applied Potential Accuracy: < 0.2%,Current Ranges: 100 Na To 5 Ma,Current Resolution: 0.006% Current Accuracy: < 0.5 % Of Current ± 0.1% Of Range,Measured Potential Resolution (For Ocp): 60 Uv (For Ocp) Impedance Measurements -Frequency Range: 10 Mhz To 200 Khz Ac-Amplitude Range: 1 Mv To 0.25 V Rms, Or 0.708 V P-P Electrometer - Electrometer Amplifier Input: > 1 T? // 10 Pf, Bandwidth: 250 Khz Other Power And Communication: Usb-C,Sensor Connector: Spe Operation Temperature Range: 0 °C To +40 °C Sensor (Spe) Connector Sensor Pitch: 2.54 Mm Electrode Connections: Re, We, Ce Maximum Sensor Thickness: Between 0.1 Mm And 0.8 Mm Maximum Sensor Width: 11 Mm Software Supported Techniques: · Voltammetric Techniques-Linear Sweep Voltammetry (Lsv), Cyclic Voltammetry (Cv) · Pulsed Techniques - Differential Pulse Voltammetry (Dpv),Square Wave Voltammetry (Swv),Normal Pulse Voltammetry (Npv) · Amperometric Techniques -Chronoamperometry (Ca),Chronocoulometry (Cc), Multistep Amperometry (Ma),Pulsed Amperometric Detection (Pad) · Potentiometric Techniques-Open Circuit Potentiometry (Ocp) · Impedimetric Techniques -Potentiostatic Electrochemical Impedance Spectroscopy, Dc-Potential Sweep, Impedance Time Scan Hg/Hgo Reference Electrode Hg/Hgso4 Reference Electrode. Last date of submission for this tender is 2025-11-01. This is a Laboratory Equipment tender in Coimbatore, Tamil Nadu

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3xlsx
  • Tender Document 4pdf
  • Tender Document 5pdf
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in