🎉 Your free trial plan has started. Plan will expire in 0 days

Rajasthan Rajya Vidyut Prasaran Nigam Ltd

jhalawar, rajasthan

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Rajasthan Rajya Vidyut Prasaran Nigam Ltd has published Tender for Procurement Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar (2X600 Mw) , Pt Turbine Stm Prs After Gov Stage1 Unit: Mpa Measuring Range: 0 To 15 User Range/Calibration Range: 0 To 15 , Pt No1 Hph Interlocking Stm Prs Unit: Mpa Measuring Range: 0 To 10 User Range/Calibration Range: 0 To 10 , Pt Hpbp Behind Stm Prs 1, Hp Turb Exhaust Stm Left Prs, Hpturb Exhaust Stm Right Prs, Hp Turb Exhaust Stm Hdr Pipe Prs, Reater Interlocking Stm Prs, Crh To Bept Stm Prs, Rh O/Lstm Press, Rh O/L Stm Press, Rh O/L Stm Press, No2 Hphi/L Stm Prs, Crh To Bfpt Stm Prs, Cold Rh Stm To Aux Stm Prs, No 2 Hph Interlocking Stm Unit: Mpa Measuring Range: 0 To 6 User Range/Calibration Range: 0 To 6 , Pt Dearator Press 1,4 Sect. Extr. To Aux Stm Prs, 4 Sect. Extr. To Dea Mov Frt Prs, 4# Extr. To Mfpt Press, Aux Stm To Bfpt, Stm Prs., Mfpt A Interlocking Stm Prs., Aux Stm To Bfpt Stm Prs, Gen Stat Cw Interlocking Wtr Flow, No5 Lph Interlocking Stm Prs, Turb Hp&Ip Gas Gland Stm Prs. 1, Gen Entering Hydrogen Pr. No5 Lph Interlocking Stm Prs Unit: Mpa Measuring Range: 0 To 2 User Range/Calibration Range: 0 To 2 , Pt Lpbp Vlv(Hp) Behind Stm Prs 1, Lpbp Vlv (Lp) Behind Stm Prs 1 Unit: Mpa Measuring Range: -0.2 To 2 User Range/Calibration Range: -0.1 To 2 , Pt No7 Lph A&B Interlocking Stm Prs, No8 Lph A&B Interlocking Stm Prs 1 Unit: Mpa Measuring Range: -0.1 To 0.1 User Range/Calibration Range: -0.1 To 0.1 , Pt Cp Inl Press Unit: Mpa Measuring Range: -0.1 To 0.5 User Range/Calibration Range: -0.1 To 0.5 , Pt Lub Oil Of Turb Prs Unit: Kpa Measuring Range: 0 To 5500 User Range/Calibration Range: 0 To 5500 , Pt Hp Cond Vacuum Pres 1, Lp Cond Vacuum Press 1, Hp Cond Vacuum Prs 1, Lp Cond Vacuum Prs 1, Bfpt B Exhaust Vac Press, Bfpt A Exhaust Vac Press Unit: Kpa Measuring Range: -100 To 100 User Range/Calibration Range: -100 To 100 , Dpt Tdbfbp A Interlocking Filter Dp, Tdbfbp B Interlocking Filter Dp, Tdbfbd O/L Feed Wtr Flow 2, Tdfpa Interlocking Filter Dp, Tdfp A Interlocking Filter Dp, Mbfbp Interlocking Filter Dp, Mbfp Interlocking Filter Dp, Rh Spray Wtr Flow, Sh Spray Wtr Flow 1, 4# Extr. To Aux Stm Flow, 4# Extr. To Mfpt Unit: Kpa Measuring Range: 0 To 100 User Range/Calibration Range: 0 To 100 , Pt Trub Self-Sealing Gland Htr Prs Unit: Kpa Measuring Range: -100 To 600 User Range/Calibration Range: -100 To 600 , Dpt Gen Stat Cw Flow, Seal Oil Dp, Hp Bpv In Steam Flow Unit: Kpa Measuring Range: 0 To 250 User Range/Calibration Range: 0 To 250 , Dpt Tdbfbp A O/L Feed Wtr Flow 1, Tdbfbp B O/L Feed Wtr Flow 1, Tdbfbp B O/L Feed Wtr Flow 3, Mbfbp O/L Feed Wtr Flow 1 Unit: Kpa Measuring Range: 0 To 40 User Range/Calibration Range: 0 To 40 , Dpt Drum Level Tx. Unit: Mmh2o Measuring Range: -800 To 800 User Range/Calibration Range: -600 To 500 Mmh2o , Dpt Pa Flow, Aph Pa Inlet & Outlet Dp, Secondary Air Flow, Aph Sa Inlet & Outlet Dp Unit: Kpa Measuring Range: -2.0 To 2.0 User Range/Calibration Range: 0.1 To 1.5 , Dpt Feed Control Stn In & Out Dp Unit: Mpa Measuring Range: -0.12 To 10.0 User Range/Calibration Range: 0 To 10.0 , Pt Furnace Press Tx., Aph Inlet And Outlet Gas Press, Esp Intel Gas Press, Id Fan Inlet Press, Gas Press Fur. Cavity Unit: Kpa Measuring Range: -8.0 To 8.0 User Range/Calibration Range: -8.0 To 1.0 , Pt Main Feedwater Press, Drum Press Tx., Sh Out Press, Main Steam Press, Sh Spray Water Press., Main Feedwater Mov Front Press., Construction Blowdown Tank Press. Unit: Mpa Measuring Range: -0.1 To 40.0 User Range/Calibration Range: 0 To 30.0 , Pt Secondary Air Pressure Tx., Aph Inlet Sec Air Press, Fd Fan Out Press, Furnace Sec. Air Box Press, Furnace Pressure Unit: Kpa Measuring Range: -60 To 60 User Range/Calibration Range: -7.0 To 7.0 , Pt Cw/Acw Header Pressure, Instrument Air Pressure, Cw Outlet Pressure Iac/Cac Air Pressure Unit: Mpa Measuring Range: 0 To 1.5 User Range/Calibration Range: 0 To 1.5 , Pt Ldo , Hfo Supply And Return Press (With Capillary) Unit: Mpa Measuring Range: 0 To 05 User Range/Calibration Range: 0.1 To 05 , Pt Prds Hdr Press Unit: Mpa Measuring Range: 0 To 6.3 User Range/Calibration Range: 0 To 5 , Pt Mill Loading Oil Pressure Unit: Mpa Measuring Range: 0 To 40 User Range/Calibration Range: 0 To 25 , Dpt Mill Sealing Air Dp, Sadc/Cadc Press Dp Unit: Kpa Measuring Range: -60 To 60 User Range/Calibration Range: 0 To 5 , Dpt Hfo Filter Dp (With Capillary) Unit: Kpa Measuring Range: -500 To 500 User Range/Calibration Range: -100 To 100 , Dpt Lo Filter Dp (With Capillary) Unit: Kpa Measuring Range: -160 To 160 User Range/Calibration Range: 0 To 100 , Dpt Mill Separator Inlet/Outlet Dp Unit: Kpa Measuring Range: 0 To 40 User Range/Calibration Range: 0 To 20 , Dpt Scanner Fan Dp Unit: Kpa Measuring Range: 0 To 8 User Range/Calibration Range: 0 To 6.2 , Pt Scanner Fan Press., Mill Separator Outlet Pressure, Mill Seal Air Pressure, Mill Pa Pressure Unit: Kpa Measuring Range: -100 To 400 User Range/Calibration Range: 0 To 30 , Pt Mill Lube Oil Pressure Line Unit :Mpa Measuring Range :-0 To 0.5 User/Calibration Range :-0 To 0.2. Last date of submission for this tender is 2026-08-06. This is a Pressure Transmitters tender in Jhalawar, Rajasthan

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

2 issued
  • Tender Document 1html
  • Tender Document 2pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in