🎉 Your free trial plan has started. Plan will expire in 0 days

Nuclear Power Corporation Of India Limited

chittorgarh, rajasthan

AOC value
₹9.55L
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Nuclear Power Corporation Of India Limited has published Bids Are invited for item-1 - M/s MECO make AC ammeter, Model ML72, input 0-5 A DC, Scale 0-2500 A AC, Deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. , item-2 - M/s MECO make AC ammeter, Model ML110, input 0-5 A DC, Scale 0-800 A AC, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-3 - M/s MECO make AC ammeter, Model ML110, input 0-5 A DC, Scale 0-200 A AC, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-4 - M/s MECO make AC ammeter, Model ML110, input 0-5 A DC, Scale 0-1000 A AC, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-5 - M/s MECO make AC ammeter model MLC110, input CTR 2500/5 A AC, Scale 0-2500 A AC Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-6 - M/s MECO make AC ammeter model MLC110, input CTR 1500/5 A AC, Scale 0-1500 A AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-7 - M/s MECO make AC ammeter model MLC110, input CTR 800/5 A AC, Scale 0-800 A AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-8 - M/s MECO make AC ammeter model MLC144, input CTR 1200/5 A AC, Scale 0-1200 A AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-9 - M/s MECO make AC ammeter model MLC110, input CTR 150/5 A AC, Scale 0-150 A AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-10 - M/s MECO make model ML110, input (-15)-0-(+75)mV DC, Scale (-500)-0-(+2500) A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-11 - M/s MECO make DC ammeter model ML110, input 0-50 mV DC, Scale 0-40 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-12 - M/s MECO make DC ammeter model ML110, input 0-75 mV DC, Scale 0-600 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-13 - M/s MECO make DC ammeter model ML110, input 0-50 mV DC, Scale 0-400 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-14 - M/s MECO make DC ammeter model ML110, input 0-75 mV DC, Scale 0-75 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-15 - M/s MECO make DC ammeter model ML110, input 0-75 mV DC, Scale 0-300 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-16 - M/s MECO make DC ammeter model ML110, input 0-75 mV DC, Scale 0-2000 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-17 - M/s MECO make DC ammeter model ML110, input 0-75 mV DC, Scale 0-30 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-18 - M/s MECO make DC ammeter model M96, input (-75)-0-(+75) mV DC, Scale (-50)-0-(+50) A DC, deflection angle 90 degree, Accuracy 1.5% of full scale as per attached specifications. , item-19 - M/s MECO make DC ammeter model ML72, input 0-75 mV DC, Scale 0-3000 A DC, deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. , item-20 - M/s MECO make DC ammeter model ML110, input 0.2-1 A DC, Scale 0.2-1 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-21 - M/s MECO make DC ammeter model ML110, input 0-5 A DC, Scale 0-5 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-22 - M/s MECO make DC ammeter model ML110, input 0-1000 micro A DC, Scale 0-1000 micro A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-23 - M/s MECO make DC ammeter model M96, input 0-5 A DC, Scale 0-5 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-24 - M/s MECO make AC voltmeter model MLC110, input PTR 420/120 V AC, Scale 0-500 V AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-25 - M/s MECO make AC voltmeter model MLC144, input PTR 420/120 V AC, Scale 0-500 V AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-26 - M/s MECO make AC voltmeter model ML72, input 0-10 mA DC, Scale 0-25 KV AC, deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. , item-27 - M/s MECO make AC voltmeter model MLC72, input 0-150 V AC , Scale 0-150 V AC, deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. , item-28 - M/s MECO make AC voltmeter model MLC110, input 0-150 V AC , Scale 0-150 V AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-29 - M/s MECO make DC voltmeter model ML110, input 0-400 V DC , Scale 0-400 V DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-30 - M/s MECO make DC voltmeter model ML110, input 0-75 V DC , Scale 0-75 V DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-31 - M/s MECO make DC voltmeter model ML110, input 0-300 V DC , Scale 0-300 V DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-32 - M/s MECO make DC voltmeter model M96, input 0-150 V DC , Scale 0-150 V DC, deflection angle 90 degree, Accuracy 1.5% of full scale as per attached specifications. , item-33 - M/s MECO make DC voltmeter model M96, input 0-50 V DC , Scale 0-50 V DC, deflection angle 90 degree, Accuracy 1.5% of full scale as per attached specifications. , item-34 - M/s MECO make DC voltmeter model ML72, input 0-60 V DC , Scale 0-60 V DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-35 - M/s MECO make DC voltmeter model ML72, input 0-60 V DC , Scale 0-60 V DC, deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. , item-36 - M/s MECO make DC voltmeter model ML72, input (-400)-0-(+400) V DC , Scale (-400)-0-(+400) V DC, deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. , item-37 - M/s MECO make DC voltmeter model ML72, input (-300)-0-(+300) V DC , Scale (-300)-0-(+300) V DC, deflection angle 90 degree, Accuracy 1.5% of full scale as per attached specifications. , item-38 - M/s MECO make Wattmeter model 110LW33, input CTR 2500/5 A AC, input PTR 420/120 V AC, Scale 0-1750 KW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-39 - M/s MECO make Wattmeter model ML110, input 4-20 mA DC, scale (-60)-0-(+300) MW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-40 - M/s MECO make Wattmeter model ML110, input 4-20mA DC, scale (-15)-0-(+75) MW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-41 - M/s MECO make Wattmeter model ML110, input 4-20 mA DC, scale (-50)-0-(+250) MW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-42 - M/s MECO make Wattmeter model ML72, input 4-20 mA DC, scale (-50)-0-(+500) KW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-43 - M/s MECO make Wattmeter model ML110, input 4-20 mA DC, scale (-50)-0-(+500) KW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-44 - M/s MECO make Wattmeter model ML72, input 4-20 mA DC, scale (-0.4)-0-(+2) MW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-45 - M/s MECO make Wattmeter model ML96, input 4-20 mA DC, scale 0-1200 KW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-46 - M/s MECO make VAR meter model 110LV33, Input CTR 2500/5 A AC, PTR 420/120 V AC, Scale (-1000)-0-(+1000) KVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-47 - M/s MECO make VAR meter model 144LV33, Input CTR 1200/5 A AC, PTR 420/120 V AC, Scale 0-800 KVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-48 - M/s MECO make VAR meter model ML72, Input 4-20 mA DC, Scale (-0.4)-0-(+2) MVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-49 - M/s MECO make VAR meter model ML110, Input 4-20 mA DC, Scale (-500)-0-(+500) KVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-50 - M/s MECO make VAR meter model ML110, Input 4-20 mA DC, Scale (-60)-0-(+300) MVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-51 - M/s MECO make VAR meter model ML110, Input 4-20 mA DC, Scale (-15)-0-(+75) MVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-52 - M/s MECO make VAR meter model ML110, Input 4-20 mA DC, Scale (-100)-0-(+200) MVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. , item-53 - M/s MECO make frequency meter model FL110, Input PTR 420/120 V AC, Scale 45-55 Hz, Deflection angle 240 degree, Accuracy 1% of full scale as per attached specifications. , item-54 - M/s MECO make frequency meter model F72, Input PTR 420/120 V AC, Scale 45-55 Hz, Deflection angle 90 degree, Accuracy 1% of full scale as per attached specifications. , item-55 - M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 2500/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale(-0.4)-0-(+2) MW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications. , item-56 - M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 800/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale(-50)-0-(+500) KW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications. , item-57 - M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 1200/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale 0-920 KW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications. , item-58 - M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 800/5 A AC, input PTR 230 KV/115 V AC, Output 4-20 mA DC corresponding to scale (-60)-0-(+300) MW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications. , item-59 - M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 200/5 A AC, input PTR 230 KV/115 V AC, Output 4-20 mA DC corresponding to scale (-15)-0-(+75) MW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications , item-60 - M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 1500/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale 0-1200 KW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications , item-61 - M/s MECO make Reactive power transducer model RPT33, type 3 phase-2 element-3 wire, input CTR 2500/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale (-0.4)-0-(+2) MVAR , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications , item-62 - M/s MECO make Reactive power transducer model RPT33, type 3 phase-2 element-3 wire, input CTR 1200/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale 0-920 KVAR, load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications , item-63 - M/s MECO make Reactive power transducer model RPT33, type 3 phase-2 element-3 wire, input CTR 800/5 A AC, input PTR 230KV/115 V AC, Output 4-20 mA DC corresponding to scale (-60)-0-(+300) MVAR , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications , item-64 - M/s MECO make Reactive power transducer model RPT33, type 3 phase-2 element-3 wire, input CTR 200/5 A AC, input PTR 230KV/115 V AC, Output 4-20 mA DC corresponding to MVAR , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications , item-65 - M/s MECO make Reactive power transducer model RPT33, type 3 phase-2 element-3 wire, input CTR 800/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale (-500)-0-(+500) KVAR , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications Total Quantity : 182. Last date of submission for this tender is 2026-04-15. This is a Ammeters tender in Chittorgarh, Rajasthan

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in