🎉 Your free trial plan has started. Plan will expire in 0 days

Nuclear Power Corporation Of India Limited

chittorgarh, rajasthan

AOC value
₹87.45L
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Nuclear Power Corporation Of India Limited has published Bids Are Invited For Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of less than 1 point 1kW rating as per Part A Scope of work Total quantity 1 is equal to 12 Nos fo.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 1 point 1 kW up to 2 point 2 kW rating as per Part A scope of work Total quantity 1.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 2 point 2 kW up to 5 point 5 kW rating as per Part A scope of work Total quantity .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 5 point 5 kW up to 11 kW rating as per Part A scope of work Total quantity 1 is e.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 11 kW up to 22 kW rating as per Part A scope of work Total quantity 1 is equal to.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 22 kW up to 55 kW rating as per Part A scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 55 kW up to 75 kW rating as per Part A scope of work Total quantity 1 is equal to.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than to 90 kW rating as per Part A scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 90 kW up to 110 kW rating as per Part A scope of work Total quantity 1 is equal to.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 110 kW up to 132 kW rating as per Part A scope of work Total quantity 1 is equal .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 132 kW up to 140 kW rating as per Part A scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 140 kW up to 180 kW rating as per Part A scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Submersible pump motors up to 2 point 5 kW rating as per Part A scope of work Total quantity 1 is equal.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Submersible pump motors more than 2 point 5 kW up to 5 point 5 kW rating as per Part A scope of work T.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Submersible pump motors more than 5 point 5 kW up to 11 kW rating as per Part A scope of work Total qua.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Submersible pump motors more than 11 kW up to 15 kW rating as per Part A scope of work Total quantity 1.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Submersible pump motors more than 15 kW up to 37 kW rating as per Part A scope of work Total quantity .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Single phase 230 V 50Hz motors of Ceiling fan 1200 mm sweep as per Part A Scope of work Total quantity 1 is equal to 75 Nos .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Single phase 230 V 50Hz motors of Pedestal fan or wall mounted fan or Exhaust fan up to 450 mm sweep as per Part A Scope of work.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Single phase 230 V 50Hz motors of Exhaust fan or cooler fan above 400 mm sweep as per Part A Scope of work Total quantity 1 is eq.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Self starter motor 24V DC Type 10TH 232 C suitable for greave diesel engine Model 64DX Mark II as per Part A Scope of work Total quan.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of 2000 VA Control Transformer as per Part A Scope of work Total quantity 1 is equal to 02 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version Part A Scope of work Total quantity 1 is equal to 02 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of 500 VA Control Transformer as per Part A Scope of work Total quantity 1 is equal to 02 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of control coil 415V Diameter up to 300MM including bobbin as per Part A Scope of work Total quantity 1 is equal to 02 Nos for two ye.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Single phase 230 V 50Hz Submersible pump motors up to 1 point 5 kW rating as per Part A scope of work Total quantity 1 is equa.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Supply and installation of Shaft for Ceiling fan or pedestal fans as per Part A scope of work Total quantity 1 is equal to 25 Nos for two years; Se.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Supply and installation of Gun metal bushes as per Part A scope of work Total quantity 1 is equal to 25 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors up to 1 point 5 kW rating as per Part B scope of work Total quantity 1 is equal to 02 No.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors of more than 1 point 5 kW up to 7 point 5 kW rating as per Part B scope of work To.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors of more than 7 point 5 kW up to 22 kW rating as per Part B scope of work Total quan.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors of more than 22 kW up to 45 kW rating as per Part B scope of work Total quantity 1 i.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors of more than 45 kW up to 90 kW rating as per Part B scope of work Total quantity 1.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors of more than 90 kW up to 180kW rating as per Part B scope of work Total quantity 1 i.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Removal of hot spot by dismantling of total stampings in Three phase 415 V 50Hz motors up to 22 kW rating as per Part B scope of work Tot.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Removal of hot spot by dismantling of total stampings in Three phase 415 V 50Hz motors of more than 22 kW up to 45 kW rating as per Part.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Removal of hot spot by dismantling of total stampings in Three phase 415 V 50Hz motors of more than 45 kW up to 90 kW rating as per Part.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version and 4; Removal of hot spot by dismantling of total stampings in Three phase 415 V 50Hz motors of more than 90 kW up to 180 kW rating as per Par.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size up to 1 point 5 kW motor as per Part B sc.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 1 point 5kW up to 7 point 5 kW.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 7 point 5 kW up to 15kW motor a.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 15 up to 45 kW motor as per Par.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 45kW up to 90 kW motor as per P.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 90kW to 180kW motor as per Part.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size up to 1 point 5 kW motor as per Part.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 1 point 5 kW up to 7 poin.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 7 point 5 kW to 15kW motor.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 15 kW up to 45 kW motor as.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 45kW up to 90 kW motor as .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 90 kW to 180kW motor as pe.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Replacement of PVC cooling fan for motors size up to 1 point 5 kW as per Part B scope of work Total quantity 1 is equal to 8 Nos for two years; Se.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Replacement of PVC cooling fan for motors size more than point 5kW up to 7 point 5 kW as per Part B scope of work Total quantity 1 is equal to 8.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Replacement of PVC cooling fan for motors size more than 7 point 5kW upto 15kW as per Part B scope of work Total quantity 1 is equal to 8 Nos for .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Replacement of PVC cooling fan for motors size more than 15kW up to 45kW as per Part B scope of work Total quantity 1 is equal to 8 Nos for two ye.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 1kg up to 4 kg as per Part B scope of work Total quantity 1 is equal to 2.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 4 kg up to 16 kg as per Part B scope of work Total quantity 1 is equal to.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 16 kg up to 48 kg as per Part B scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 48 kg up to 96 kg as per Part B scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 96 kg up to 192 kg as per Part B scope of work Total quantity 1 is equal .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 192 kg up to 378 kg as per Part B scope of work Total quantity 1 is equal.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 378 kg up to 500 kg as per Part B scope of work Total quantity 1 is equal.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 500 kg up to 1000 kg as per Part B scope of work Total quantity 1 is equa.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 1000 kg up to 1500 kg as per Part B scope of work Total quantity 1 is equ.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 1500 kg up to 3000 kg as per Part B scope of work Total quantity 1 is equ.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Supply and installation of terminal plate or terminal studs with insulators One quantity includes terminal studs for all three phases size up to 1 .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Supply and installation of terminal plate or terminal studs with insulators One quantity includes terminal studs for all three phases size more tha.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and Supply and installation of terminal plate or terminal studs with insulators One quantity includes terminal studs for all three phases size more th.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Removing of shaft making of new shaft and refitting of shaft with key way Material used shall be same as original and material is in contractor sco.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size up to 1 point 5 kW Material cast iron for above end cover is in contra.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size more than 1 point 5kW up to 7 point 5 kW Material cast iron for above .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size more than 7 point 5kW up to 15kW Material cast iron for above end cove.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size more than 15kW up to 45kW Material cast iron for above end cover is in .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size more than 45kW up to 90kW Material cast iron for above end cover is in.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size more than 90kW up to 180kW Material cast iron for above end cover is in.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size up to 1 point 5 kW as per Part B scope of work Total quanti.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size more than 1 point 5kW up to 7 point 5 kW as per Part B scope.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size more than 7 point 5kW up to 15kW as per Part B scope of work .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size more than 15kW up to 45kW as per Part B scope of work Total q.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size more than 45kW up to 90kW as per Part B scope of work Total.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size more than 90kW up to 180kW as per Part B scope of work Total.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Material cost iron for making of cooling fan end cover as per Part B scope of work Total quantity to 100 Kg for two years; Service Provi.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size up to 1 point 5 kW as per Part B scope of work Total quantity 1 is eq.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size more than 1 point 5kW up to 7 point 5 kW as per Part B scope of work .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size more than 7 point 5kW up to 15kW as per Part B scope of work Total qu.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size more than 15Kw up to 45kW as per Part B scope of work Total quantity .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size more than 45kW up to 90kW as per Part B scope of work Total quantity 1.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size more than 90kW up to 180kW as per Part B scope of work Total quantity .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing locks duly machined threaded and drilled with material Same as original size up to 15kW as per Part B scope of work.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing locks duly machined threaded and drilled with material Same as original size more than 15kW up to 45kW as per Part .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing locks duly machined threaded and drilled with material Same as original size more than 45kW up to 90kW as per Part .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing locks duly machined threaded and drilled with material Same as original size more than 90kW to 180kW as per Part B.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of foundation legs including machining drilling and levelling etc Material shall be in contractor scope size up to 1 point 5 k.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of foundation legs including machining drilling and levelling etc Material shall be in contractor scope size more than 1 point.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of foundation legs including machining drilling and levelling etc Material shall be in contractor scope size more than 7 point.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of foundation legs including machining drilling and levelling etc Material shall be in contractor scope size more than 15 up t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site Dismantling and refitting without varnish and baking size up to 1 point 5 kW as per Part B scope of work Total quantity 1 is equal to 2 Nos for tw.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting without varnish and baking size more than 1 point 5kW up to 7 point 5kW as per Part B scope of work Total quantity 1 is e.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting without varnish and baking size more than 7 point 5kW up to 15kW as per Part B scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting without varnish and baking size more than 15kW up to 45kW as per Part B scope of work Total quantity 1 is equal to 2 Nos .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting without varnish and baking size more than 45kW up to 90kW as per Part B scope of work Total quantity 1 is equal to 1 Nos.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting without varnish and baking size more than 90kW up to 180kW as per Part B scope of work Total quantity 1 is equal to 1 No.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size up to 1 point 5 kW as per Part B scope of work Total quantity 1 is equal to 5 Nos for two y.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size more than 1 point 5kW up to 7 point 5kW as per Part B scope of work Total quantity 1 is equa.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size more than 7 point 5kW up to 15kW as per Part B scope of work Total quantity 1 is equal to 3 .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size more than 15kW up to 45kW as per Part B scope of work Total quantity 1 is equal to 3 Nos for.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size more than 45kW up to 90kW as per Part B scope of work Total quantity 1 is equal to 2 Nos for.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size more than 90kW up to 180kW as per Part B scope of work Total quantity 1 is equal to 3 Nos fo.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of oil seal size less than 1 point 1 kW as per Part B scope of work Total quantity 1 is equal to 5 Nos for two years; Service.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of oil seal size 1 point 1 kW to 2 point 2 kW as per Part B scope of work Total quantity 1 is equal to 5 Nos for two years; .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of oil seal size more than 2 point 2 kW up to 5 point 5 kW as per Part B scope of work Total quantity 1 is equal to 5 Nos f.. , Repair, Maintenance Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of oil seal size more than 5 point 5 kW up to 15 kW as per Part B scope of work Total quantity 1 is equal to 5 Nos for two y.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of oil seal size more than 15kW up to 30kW as per Part B scope of work Total quantity 1 is equal to 5 Nos for two years; Ser.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of Space Heater size More than 30 up to 45kW as per Part B scope of work Total quantity 1 is equal to 2 Nos for two years; Se.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of Space Heater size More than 45kW up to 90kW as per Part B scope of work Total quantity 1 is equal to 2 Nos for two years; S.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of Space Heater size More than 90kW up to 180kW as per Part B scope of work Total quantity 1 is equal to 2 Nos for two years; .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6203 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6204 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6205 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6206 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6208 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6209 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6310 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6312 as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6312 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6313 C3 as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors size More than 90 kW up to 110 kW as per Part C scope of work Total quantity 1 is equal to 1 Nos for t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors size More than 110 kW up to 132 kW as per Part C scope of work Total quantity 1 is equal to 1 Nos for.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors 1. Rewinding of Three phase, 415 V, 50Hz, motors of less than 1.1kW rating as per Part-A, Scope of work. (Total quantity 1 is equal to 12 Nos. for two years). Price/Qty. 1 2. Rewinding of Three phase, 415 V, 50Hz, motors of more than 1.1 kW up to 2.2 kW rating as per Part-A scope of work (Total quantity 1 is equal to 12 Nos. for two years). Price/Qty. 1 3. Rewinding of Three phase, 415 V, 50Hz, motors of more than 2.2 kW up to 5.5 kW rating as per Part-A scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty. 1 4. Rewinding of Three phase, 415 V, 50Hz, motors of more than 5.5 kW up to 11 kW rating as per Part-A scope of work (Total quantity 1 is equal to 08 Nos. for two years). Price/Qty. 1 5. Rewinding of Three phase, 415 V, 50Hz, motors of more than 11 kW up to 22 kW rating as per Part-A scope of work (Total quantity 1 is equal to 05 Nos. for two years). Price/Qty. 1 6. Rewinding of Three phase, 415 V, 50Hz, motors of more than 22 kW up to 55 kW rating as per Part-A scope of work (Total quantity 1 is equal to 05 Nos. for two years). Price/Qty. 1 7. Rewinding of Three phase, 415 V, 50Hz, motors of more than 55 kW up to 75 kW rating as per Part-A scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty. 1 8. Rewinding of Three phase, 415 V, 50Hz, motors of more than 75 kW up to 90 kW rating as per Part-A scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty. 1 9. Rewinding of Three phase, 415 V, 50Hz, motors of more than 90 kW up to 110 kW rating as per Part-A scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty. 1 10. Rewinding of Three phase, 415 V, 50Hz, motors of more than 110 kW up to 132 kW rating as per Part-A scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty. 1 11. Rewinding of Three phase, 415 V, 50Hz, motors of more than 132 kW up to 140 kW rating as per Part-A scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty. 1 12. Rewinding of Three phase, 415 V, 50Hz, motors of more than 140 kW up to 180 kW rating as per Part-A scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty. 1 13. Rewinding of Three phase, 415 V, 50Hz, Submersible pump motors up to 2.5 kW rating as per Part-A scope of work (Total quantity 1 is equal to 06 Nos. for two years). Price/Qty. 1 14. Rewinding of Three phase, 415 V, 50Hz, Submersible pump motors more than 2.5 kW up to 5.5 kW rating as per Part-A scope of work (Total quantity 1 is equal to 06 Nos. for two years). Price/Qty. 1 15. Rewinding of Three phase, 415 V, 50Hz, Submersible pump motors more than 5.5 kW up to 11 kW rating as per Part-A scope of work (Total quantity 1 is equal to 03 Nos. for two years). Price/Qty. 1 16. Rewinding of Three phase, 415 V, 50Hz, Submersible pump motors more than 11 kW up to 15 kW rating as per Part-A scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty. 1 17. Rewinding of Three phase, 415 V, 50Hz, Submersible pump motors more than 15 kW up to 37 kW rating as per Part-A scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty. 1 18. Rewinding of Single phase, 230 V, 50Hz, motors of Ceiling fan 1200 mm sweep as per Part-A, Scope of work. (Total quantity 1 is equal to 75 Nos. for two years). Price19. Rewinding of Single phase, 230 V, 50Hz, motors of Pedestal fan/ wall mounted fan/ Exhaust fan up to 450 mm sweep as per Part-A, Scope of work. (Total quantity 1 is equal to 150 Nos. for two years). Price/Qty 1 20. Rewinding of Single phase, 230 V, 50Hz, motors of Exhaust fan/cooler fan above 400 mm sweep as per Part-A, Scope of work. (Total quantity 1 is equal to 50 Nos. for two years). Price/Qty 1 21. Rewinding of Self-starter motor, 24V, DC, Type 10TH-232-C suitable for greave diesel engine, Model -64DX-Mark-II as per Part-A, Scope of work. (Total quantity 1 is equal to 04 Nos. for two years). Price/Qty 1 22. Rewinding of 2000 VA Control Transformer as per Part-A, Scope of work. (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 23. Rewinding of 1000 VA Control Transformer as per Part-A, Scope of work. (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 24. Rewinding of 500 VA Control Transformer as per Part-A, Scope of work. (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 25. Rewinding of control coil 415V, Diameter up to 300MM including bobbin as per Part-A, Scope of work. (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 26. Rewinding of Single phase, 230 V, 50Hz, Submersible pump motors up to 1.5 kW rating as per Part-A scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 27. Supply and installation of Shaft for Ceiling fan/pedestal fans as per Part-A scope of work (Total quantity 1 is equal to 25 Nos. for two years). Price/Qty 1 28. Supply and installation of Gun metal bushes as per Part-A scope of work (Total quantity 1 is equal to 25 Nos. for two years). Price/Qty 1 29. Repair of hot spot in Three phase, 415 V, 50Hz, motors up to 1.5 kW rating as per Part-B scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 30. Repair of hot spot in Three phase, 415 V, 50Hz, motors of more than 1.5 kW up to 7.5 kW rating as per Part-B scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 31. Repair of hot spot in Three phase, 415 V, 50Hz, motors of more than 7.5 kW up to 22 kW rating as per Part-B scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty 1 32. Repair of hot spot in Three phase, 415 V, 50Hz, motors of more than 22 kW up to 45 kW rating as per Part-B scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty 1 33. Repair of hot spot in Three phase, 415 V, 50Hz, motors of more than 45 kW up to 90 kW rating as per Part-B scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty 1 34. Repair of hot spot in Three phase, 415 V, 50Hz, motors of more than 90 kW up to 180kW rating as per Part-B scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty 1 35. Removal of hot-spot by dismantling of total stampings in Three phase, 415 V, 50Hz, motors up to 22 kW rating as per Part-B scope of work (Total quantity 1 is equal to 25 per cm for two years). Price/Qty 1 36. Removal of hot-spot by dismantling of total stampings in Three phase, 415 V, 50Hz, motors of more than 22 kW up to 45 kW rating as per Part-B scope of work (Total quantity 1 is equal to 25 per cm for two years). Price/Qty 1 37. Removal of hot-spot by dismantling of total stampings in Three phase, 415 V, 50Hz, motors of more than 45 kW up to 90 kW rating as per Part-B scope of work (Total quantity 1 is equal to 40 per cm for two years). Price/Qty 1 38. Removal of hot-spot by dismantling of total stampings in Three phase, 415 V, 50Hz, motors of more than 90 kW up to 180 kW rating as per Part-B scope of work (Total quantity 1 is equal to 40 per cm for two years). Price/Qty 1 39. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size up to 1.5 kW motor as per Part-B scope of work (Total quantity 1 is equal to 15 Nos. for two years). 40. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 1.5kW up to 7.5 kW motor as per Part- B scope of work (Total quantity 1 is equal to 15 Nos. for two years). Price/Qty 1 41. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 7.5 kW up to 15kW motor as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 42. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 15 up to 45 kW motor as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 43. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 45kW up to 90 kW motor as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 44. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 90kW to 180kW motor as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 45. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size up to 1.5 kW motor as per Part-B scope of work (Total quantity 1 is equal to 15 Nos. for two years). Price/Qty 1 46. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 1.5 kW up to 7.5 kW motor as per Part-B scope of work (Total quantity 1 is equal to 15 Nos. for two years). Price/Qty 1 47. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 7.5 kW to 15kW motor as per Part-B scope of work (Total quantity 1 is equal to 12 Nos. for two years). Price/Qty 1 48. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 15 kW up to 45 kW motor as per Part-B scope of work (Total quantity 1 is equal to 12 Nos. for two years). Price/Qty 1 49. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 45kW up to 90 kW motor as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 50. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 90 kW to 180kW motor as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 51. Replacement of PVC cooling fan for motors size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 8 Nos. for two years). Price/Qty 1 52. Replacement of PVC cooling fan for motors size more than 1.5kW up to 7.5 kW as per Part-B scope of work (Total quantity 1 is equal to 8 Nos. for two years). Price/Qty 1 53. Replacement of PVC cooling fan for motors size more than 7.5kW unto 15kW as per Part-B scope of work (Total quantity 1 is equal to 8 Nos. for two years). Price/Qty 1 54. Replacement of PVC cooling fan for motors size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 8 Nos. for two years). Price/Qty 1 55. Dynamic balancing of rotor with 2.5microns accuracy size more than 1kg up to 4 kg as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 56. Dynamic balancing of rotor with 2.5microns accuracy size more than 4 kg up to 16 kg as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 57. Dynamic balancing of rotor with 2.5microns accuracy size more than 16 kg up to 48 kg as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 58. Dynamic balancing of rotor with 2.5microns accuracy size more than 48 kg up to 96 kg as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 59. Dynamic balancing of rotor with 2.5microns accuracy size more than 96 kg up to 192 kg as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). 60. Dynamic balancing of rotor with 2.5microns accuracy size more than 192 kg up to 378 kg as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 61. Dynamic balancing of rotor with 2.5microns accuracy size more than 378 kg up to 500 kg as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 62. Dynamic balancing of rotor with 2.5microns accuracy size more than 500 kg up to 1000 kg as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 63. Dynamic balancing of rotor with 2.5microns accuracy size more than 1000 kg up to 1500 kg as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 64. Dynamic balancing of rotor with 2.5microns accuracy size more than 1500 kg up to 3000 kg as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 65. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size up to 1.5kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 66. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size more than 1.5kW up to 7.5kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 67. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 68. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 69. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 70. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size more than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 71. Removing of shaft, making of new shaft & refitting of shaft with key way. (Material used shall be same as original and material is in contractor scope) size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 72. Removing of shaft, making of new shaft & refitting of shaft with key way. (Material used shall be same as original and material is in contractor scope) size more than 1.5kW up to 7.5 kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 73. Removing of shaft, making of new shaft & refitting of shaft with key way. (Material used shall be same as original and material is in contractor scope) size more than 7.5kW to 15kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 74. Removing of shaft, making of new shaft & refitting of shaft with key way. (Material used shall be same as original and material is in contractor scope) size more than 15kW to 45 kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 75. Making of end cover including , machining, drilling and threading etc. to size up to 1.5 kW ( Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). 76. Making of end cover including , machining, drilling and threading etc. to size more than 1.5kW up to 7.5 kW ( Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 77. Making of end cover including , machining, drilling and threading etc. to size more than 7.5kW up to 15kW ( Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 78. Making of end cover including , machining, drilling and threading etc. to size more than 15kW up to 45kW (Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 79. Making of end cover including , machining, drilling and threading etc. to size more than 45kW up to 90kW ( Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 80. Making of end cover including , machining, drilling and threading etc. to size more than 90kW up to 180kW ( Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 81. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 82. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size more than 1.5kW up to 7.5 kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 83. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 84. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 85. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 86. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size more than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 87. Material cost iron for making of cooling fan, end cover as per Part-B scope of work (Total quantity 1 is equal to 100 Kg for two years). Price/Qty 1 88. Providing & fixing of bearing plates with material (Same as original) size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 89. Providing & fixing of bearing plates with material (Same as original) size more than 1.5kW up to 7.5 kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 90. Providing & fixing of bearing plates with material (Same as original) size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 91. Providing & fixing of bearing plates with material (Same as original) size more than 15Kw up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 92. Providing & fixing of bearing plates with material (Same as original) size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 93. Providing & fixing of bearing plates with material (Same as original) size more than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). 94. Providing and fixing of bearing locks (duly machined threaded & drilled) with material (Same as original) size up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 95. Providing and fixing of bearing locks (duly machined threaded & drilled) with material (Same as original) size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 96. Providing and fixing of bearing locks (duly machined threaded & drilled) with material (Same as original) size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 97. Providing and fixing of bearing locks (duly machined threaded & drilled) with material (Same as original) size more than 90kW to 180kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 98. Providing & fixing of foundation legs including machining, drilling & levelling etc. (Material shall be in contractor scope) size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 99. Providing & fixing of foundation legs including machining, drilling & levelling etc. (Material shall be in contractor scope) size more than 1.5kW up to 7.5 kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 100. Providing & fixing of foundation legs including machining, drilling & levelling etc. (Material shall be in contractor scope) size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 101. Providing & fixing of foundation legs including machining, drilling & levelling etc. (Material shall be in contractor scope) size more than 15 up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 102. Dismantling and refitting without varnish and baking size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 103. Dismantling and refitting without varnish and baking size more than 1.5kW up to 7.5kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 104. Dismantling and refitting without varnish and baking size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 105. Dismantling and refitting without varnish and baking size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 106. Dismantling and refitting without varnish and baking size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 107. Dismantling and refitting without varnish and baking size more than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 108. Dismantling and refitting with varnish and baking size up to 1.5 kW as per Part- B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 109. Dismantling and refitting with varnish and baking size more than 1.5kW up to 7.5kW as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 110. Dismantling and refitting with varnish and baking size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 3 Nos. for two years). Price/Qty 1 111. Dismantling and refitting with varnish and baking size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 3 Nos. for two years). Price/Qty 1 112. Dismantling and refitting with varnish and baking size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 113. Dismantling and refitting with varnish and baking size more than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 3 Nos. for two years). 114. Providing & Fixing of oil seal size less than 1.1 kW as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 115. Providing & Fixing of oil seal size 1.1 kW to 2.2 kW as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 116. Providing & Fixing of oil seal size more than 2.2 kW up to 5.5 kW as per Part- B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 117. Providing & Fixing of oil seal size more than 5.5 kW up to 15 kW as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 118. Providing & Fixing of oil seal size more than 15kW up to 30kW as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 119. Providing & Fixing of Space Heater size More than 30 up to 45kW as per Part- B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 120. Providing & Fixing of Space Heater size More than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 121. Providing & Fixing of Space Heater size More than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 122. Providing of SKF make Bearing 6203 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 123. Providing of SKF make Bearing 6204 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 124. Providing of SKF make Bearing 6205 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 125. Providing of SKF make Bearing 6206 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 126. Providing of SKF make Bearing 6208 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 127. Providing of SKF make Bearing 6209 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 128. Providing of SKF make Bearing 6310 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 129. Providing of SKF make Bearing 6312 as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 130. Providing of SKF make Bearing 6312 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 131. Providing of SKF make Bearing 6313-C3 as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 132. Rewinding of Three phase, 415 V, 50Hz, motors size more than 75 kW up to 90 kW as per Part-C scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 133. Rewinding of Three phase, 415 V, 50Hz, motors size More than 90 kW up to 110 kW as per Part-C scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 134. Rewinding of Three phase, 415 V , 50Hz, motors size More than 110 kW up to 132 kW as per Part-C scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 135. Rewinding of Three phase, 415 V, 50Hz, motors size More than 132 kW up to 140 kW as per Part-C scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 136. Rewinding of Three phase, 415 V, 50Hz, windings motors size More than 140 kW up to 180 kW as per Part-C scope of work (Total quantity 1 is equal to Total Quantity : 1. Last date of submission for this tender is 2025-05-02. This is a Mechanical Engineering Service tender in Chittorgarh, Rajasthan

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in