🎉 Your free trial plan has started. Plan will expire in 0 days

Military Engineer Services

Apparel And Personal Care
bharatpur, rajasthan
AOC Value₹24.02 Lac
AOC Date22 Sep 2022
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
22/09/2022
Authority
Military Engineer Services
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
55(00)/2025-2026/XXX/5XX
Bidding URL
https://www.exampletenders.gov.in/bid/98765
Tender
View Tender
Bidder Details
Bidder Name: Mr. Jhon Doe, Ranking 2

AOC Description

Military Engineer Services has published Provision Of Certain Sanctioned Work Part-I At Bharatpur Mil Stn=- 1 Excavation In Trenches, N. Exc 1.5 Mtr Wide And N. Exc 1.5 Mtr In Depth For Foundation / Laying Of Cable And Getting Out In Soft / Loose Soil. 2 Removing Of Excavated Soil To A Distance N. Exc 50 Mtr And Depositing Where Directed At A Level N. Exc 1.5 Mtr Above The Starting Point 3 Returning, Filling In Including Spreading, Levelling, Watering And Well Ramming In Layers N. Exc 25 Cm Thick. 4 Supply & Spread Unwashed Dry Local River Sand For Sand Cushioning And Covering The Under Ground Cable In Trenches. ( Note :- Punning Thickness Shall Be Measured. ) 5 M&L For Brick Protectionwith Sub Class`B` Bricks Old Size Laid Dry, Flat Over Cable Perpendicular Across The Cable In Trenches Complete All As Directed. 6 Taking Down Acsr Over Head Aluminium Conductor Steel Reinforcedalongwith Cross Arms Accessories Of Any Size All As Specified And Directed Including Stringing / Dismatling Through Rcc / Steel Tubular Poles, Fixing On Insulators, Jumpering With Aluminium Binding Wire Etc Complete All As Specified And As Directed By Engr-In-Charge 7 Supply, Laying, Testing & Commissioning Lt Xlpe Insulated Armoured ( Heavy Duty ) Electric Cable With Stranded Aluminium Conductor 1100 Volts Grade ( Isi Marked ) & Laid In Trenches / Pipes Or Fixed On Pole Of The Following Sizes:-95 Sqmm 3.5 Core 8 70 Sqmm 3.5 Core 9 50 Sqmm 3.5 Core 10 35 Sqmm 3.5 Core 11 16 Sqmm 4 Core 12 10 Sqmm 2 Core 13 Material And Labour For Renewal Of Earthing Complete With Galvanized Iron Earth Plate Electrode 600 Mm X 600 Mm X 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 M Deep Below Normal Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Deep Below Normal Ground Connected To Galvanised Gi Strip Of Size 32 X 6Mm By Means Of Bolts Nuts Check Nuts And Washer Of Galvanized Steel, Watering Pipe Of 20 Mm Bore Galvanised Iron Medium Grade And 40 Mm Bore Galvanised Iron Light Grade For Earth Strip Protectionincluding All Excavation Earth Work In Any Type Of Soil, Pcc Pitin Pcc 1:2:4 Type B-1 And Rcc 1:2:4, Type B1 For Precast Chamber Cover 50 Mm Thick, Reinforced With Welded Steel Wire Fabric Or Xpm Jali ( Weight Not Less Than 4.00 Kg / Sqm ) , With Charcoal, Salt, Funnel Complete All As Shown In The Electrical Plate No 3 Of Ssr Part –I And Testing On Completion.Note:-Quoted Rates Shall Be Deemed To Include For Earth Strip With Protection Pipe Up To 7.5 M Length. 14 Supply, Install, Testing And Commissioning Factory Made ( Cpri Test Certified ) Lt Panel Box ( Kiosk ) Out Door Typeplatform Mounted Suitable For 415 Volt , 3 Phases, 4 Wire , 50 Hz Acsupply System All As Specified And Directed Having Busbar Chamber With Insulated Al Bus Bars Installed On Percelain Insulators, The Panel Shall Be Dust And Vermin Proof Double Door Made Of 3.15 Mm Crca Ms Sheet Outer & Inner 2 Mm Thick And Individual Compartment For Mccb / Mcb & Volt / Ampsmeter And 50 X 50 X 5 Mm Thick Angle Iron And 0.75 M Long For Base Frame Work.The Complete Feeder Pillar Box Should Be Powder Coated Including Internal Wiring With Pvc Insulated Solid Copper Conductor Frls Cables Appropriate Size But Not Less Than 4 Sqmm. Front And Back Opening Type With Approxsize For Cable Entry With Double Door Shutter Including Locking Arrangement As Per Manufacturers With 2 Keys. ( A ) Incoming- Mccb 4 Pole 160 A , 415V, 18 Ka Adjustable Type With Magnetic Release-01 No. ( B ) Digital Voltmeter Size 96 X 96 Mm, 0-600 Volts With Selector Switch -01 No. ( C ) Digital Ammeter Size 96 X 96 Mm 0-400 Amps, Cts, Ctr 0-400 Amps With Selector Switch - 01 No. ( D ) Busbar Alluminium 250 A Capacity Note:Panel Mounted On 45 Cm Height Pcc Platform Above Ground Level And 0.15 Below Ground Level 15 Supply, Install, Testing And Commissioning Factory Made ( Cpri Test Certified ) Lt Panel Box ( Kiosk ) Out Door Typeplatform Mounted Suitable For 415 Volt , 3 Phases, 4 Wire , 50 Hz Acsupply System All As Specified And Directed Having Busbar Chamber With Insulated Al Bus Bars Installed On Percelain Insulators, The Panel Shall Be Dust And Vermin Proof Double Door Made Of 3.15 Mm Crca Ms Sheet Outer & Inner 2 Mm Thick And Individual Compartment For Mccb / Mcb & Volt / Ampsmeter And 50 X 50 X 5 Mm Thick Angle Iron And 0.75 M Long For Base Frame Work.The Complete Feeder Pillar Box Should Be Powder Coated Including Internal Wiring With Pvc Insulated Solid Copper Conductor Frls Cables Appropriate Size But Not Less Than 4 Sqmm. Front And Back Opening Type With Approxsize For Cable Entry With Double Door Shutter Including Locking Arrangement As Per Manufacturers With 2 Keys. ( A ) Incoming- Mccb 4 Pole 125 A , 415V, 18 Ka Adjustable Type With Magnetic Release-01 No. ( B ) Digital Voltmeter Size 96 X 96 Mm, 0-600 Volts With Selector Switch -01 No. ( C ) Digital Ammeter Size 96 X 96 Mm 0-400 Amps, Cts, Ctr 0-400 Amps With Selector Switch - 01 No. ( D ) Busbar Alluminium 200 A Capacitynote:Panel Mounted On 45 Cm Height Pcc Platform Above Ground Level And 0.15 Below Ground Level 16 Supply, Install, Testing And Commissioning Factory Made ( Cpri Test Certified ) Lt Panel Boxout Door Typeplatform Mounted Suitable For 415 Volt , 3 Phases, 4 Wire , 50 Hz Acsupply System All As Specified And Directed Having Busbar Chamber With Insulated Alinstalled On Percelain Insulators, The Panel Shall Be Dust And Vermin Proof Double Door Made Of 3.15 Mm Crca Ms Sheet Outer & Inner 2 Mm Thick And Individual Compartment For Mccb / Mcb & Volt / Ampsmeter And 50 X 50 X 5 Mm Thick Angle Iron And 0.75 M Long For Base Frame Work.The Complete Feeder Pillar Box Should Be Powder Coated Including Internal Wiring With Pvc Insulated Solid Copper Conductor Frls Cables Appropriate Size But Not Less Than 4 Sqmm. Front And Back Opening Type With Approxsize For Cable Entry With Double Door Shutter Including Locking Arrangement As Per Manufacturers With 2 Keys. ( A ) Incoming- Mccb 4 Pole 160A , 415V, 35 Ka Adjustable Type With Magnetic Release-01No.Out Going- ( B ) Mccb 4 Pole 100 A , 415V, 18 Ka Adjustable Type With Magnetic Release - 01 Nos ( C ) Mccb 4 Pole 63 A , 415V, 18 Ka Adjustable Type With Magnetic Release - 02 Nos ( D ) Digital Voltmeter Size 96 X 96 Mm, 0-600 Volts With Selector Switch -01 No. ( E ) Digital Ammeter Size 96 X 96 Mm 0-400 Amps, Cts, Ctr 0-400 Amps With Selector Switch - 01 No. ( F ) Busbar Alluminium 400 A Capacity For Phase & Neutral -04 No.Note:Panel Mounted On 45 Cm Height Pcc Platform Above Ground Level And 0.15 Below Ground Level 17 Supply, Install, Testing And Commissioning Factory Made ( Cpri Test Certified ) Lt Panel Box ( Kiosk ) Out Door Typeplatform Mounted Suitable For 415 Volt , 3 Phases, 4 Wire , 50 Hz Acsupply System All As Specified And Directed Having Busbar Chamber With Insulated Al Bus Bars Installed On Percelain Insulators, The Panel Shall Be Dust And Vermin Proof Double Door Made Of 3.15 Mm Crca Ms Sheet Outer & Inner 2 Mm Thick And Individual Compartment For Mccb / Mcb & Volt / Ampsmeter And 50 X 50 X 5 Mm Thick Angle Iron And 0.75 M Long For Base Frame Work.The Complete Feeder Pillar Box Should Be Powder Coated Including Internal Wiring With Pvc Insulated Solid Copper Conductor Frls Cables Appropriate Size But Not Less Than 4 Sqmm. Front And Back Opening Type With Approxsize For Cable Entry With Double Door Shutter Including Locking Arrangement As Per Manufacturers With 2 Keys. ( A ) Incoming- Mccb 4 Pole 63 A , 415V, 18 Ka Adjustable Type With Magnetic Release-01 No. ( B ) Digital Voltmeter Size 96 X 96 Mm, 0-600 Volts With Selector Switch -01 No. ( C ) Digital Ammeter Size 96 X 96 Mm 0-400 Amps, Cts, Ctr 0-400 Amps With Selector Switch - 01 No. ( D ) Busbar Alluminium 100 A Capacitynote:Panel Mounted On 45 Cm Height Pcc Platform Above Ground Level And 0.15 Below Ground Level 18 M&L For Road Cutting In 300Mm Width & 450 Mm Depth & Repair To Existing With Bitumen Premixed Incl 150 Mm Bm Complete All As Specified And Directed By Engg In Charge. 19 Supply & Fixin Repair Mcb 63 Amp, 4 Pole, Fixed Type Breaking Capacity 16 Ka, 415 V - 50 Hz, Fixed In Existing Panel & Connecting Complete All As Specified And Directed By Engg-In-Charge. 20 Supply & Fixin Repair Mccb 63 Amp, 4 Pole, Fixed Type Breaking Capacity 18 Ka, 415 V - 50 Hz, Fixed In Existing Panel & Connecting Complete All As Specified And Directed By Engg-In-Charge. 21 Supply & Fixin Repair Mccb 160 Amp, 4 Pole, Adjustable Type Breaking Capacity 36 Ka, 415 V - 50 Hz, Fixed In Existing Panel & Connecting Complete All As Specified & Directedby Engr-In-Charge. 22 Supply & Fixin Repair Mccb 200 Amp, 4 Pole, Adjustable Type Breaking Capacity 36 Ka, 415 V - 50 Hz, Fixed In Existing Panel & Connecting Complete All As Specified & Directedby Engr-In-Charge. 23 S & F Street Light Gi Bracket Of 1.2 Mtr Long Made Out Of 40 Mm Dia Light Grade Gi Pipe Bend To Shape Of 120 Degree End Welded At Required Including 02 Nos Ms Clamp Of Fl 40 X 6Mm Including Nuts Bolts & Washers Complete Necessary Fixing Arrangements On Pole As Directed. 24 Supply, Install, Test And Commissioning Factory Made Hdpe / Thermoplastic Cable Junction Boxes “Weather Proof”, With Terminals For Outdoor Installation ( With Knockouts For Cable Entry ) With Cable Entry Size Of 10-25 Sqmm With 4 No. 63 Amp Busbar And 01 No 06 Amp Sp Mcb With Cableglands Including With Flat Iron Clamps Of Size 30 X 6Mm, Nuts And Bolts. 25 S&F 60 Watts Led Streetlight Fitings New Generation Energy Saving, Environmental Friendly, Long Life, Versatile Pressure Die Cast Aluminium Ip66 With 10Kv Surge Protection Road Way, Luminaire With High Power Led As Light Source With Warranty Option Of 5 Years And Suitable Drivers Etc And Connecting With 4.0 Sq Mm Multistranded Aluminium Conductor Pvc Insulated Twin Core Weather Proof Cable From Fittings To Over Head Lines Or To The Jucntion Box And Fixing To Complete All As Specified And Directed , 26 S&F Of Automatic Street Light Switch Using Infrared Sensor Based Nature Switch For Automatic Switching Of Street Lights. Nature Switch Operation Switch Operation Should Be Basedon Natural Light Lux Level. Required Illuminancelevel For Switching On Is<= 30 Lux Andfor Switching Off>=10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min 4 Hours To Max 12 Hours. The Sensor Along With Suitable Power Contactors, Incoming-Outgoing McbS And Auto Manual ( Sensor By-Pass ) Selection Option Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Ip66 Protection Class 2 Enclosure Made Of Thermoplastic Polycarbonate And Protected Against Weather Influences. For Three Phase Load Of 5Kw ( Swadeep-665Kw3p ) With: 3 Nos Contactors, 3 Nos Incoming McbS & 3 Nos Outgoing McbS Of 20-25 Amps Each & Circuit Wiring ( Copper ) Of Min 10 Sqmm Complete All As Specified And Directed By Engg In Charge..Make:Nature Switch:Kakatiya Energy System / Bajaj / Healer, Contactors:Bch / L&T / Sschneider, McbS: Hager / Schneider / L&T ( Exora / Au Series ) / C&S. 27 Supply & Lay G I Tubinglight Grade In Protection Of Cable At Road Crossing / Hard Standing / Pole Protection Fixed With Clamps As Per Site Requirement Etc All As Specified Anddirected For Following Sizes :- 40 Mm Dia 28 S & F In Replacement 4 Sqmm Solid Conductor 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed Twin Core Cable Flat Or Circular From Junction Boxto Fitting Complete All As Directed By Engineer-In-Charge. 29 S&F 20 Mm Dia Medium Grade Pvc Conduit Fixed On Pole With Ms Clamps Made Out 25 X 3 Mm Thick Ms Flat With The Size Of Pole , Nut, Bolt Etc At The Interval Of 2 Meter All As Specified And Directed 30 Supply, Install, Testing And Commissioning Factory Made ( Cpri Test Certified ) Lt Panel Box ( Kiosk ) Out Door Typeplatform Mounted Suitable For 415 Volt , 3 Phases, 4 Wire , 50 Hz Acsupply System All As Specified And Directed Having Busbar Chamber With Insulated Al Bus Bars Installed On Percelain Insulators, The Panel Shall Be Dust And Vermin Proof Double Door Made Of 3.15 Mm Crca Ms Sheet Outer & Inner 2 Mm Thick And Individual Compartment For Mccb / Mcb & Volt / Ampsmeter And 50 X 50 X 5 Mm Thick Angle Iron And 0.75 M Longfor Base Frame Work.The Complete Feeder Pillar Box Should Be Powder Coated Including Internal Wiring With Pvc Insulated Solid Copper Conductor Frls Cables Appropriate Size But Not Less Than 4 Sqmm. Front And Back Opening Type With Approxsize For Cable Entry With Double Door Shutter Including Locking Arrangement As Per Manufacturers With 2 Keys. Incoming ( A ) Mccb 4 Pole 125 A , 415V, 18 Ka Adjustable Type With Magnetic Release -01 No.Outgoing ( A ) Mcb Tpn 63 A , 415V, 16 Ka- 04 Nos ( B ) Digital Voltmeter Size 96 X 96 Mm, 0-600 Volts With Selector Switch -01 No. ( C ) Digital Ammeter Size 96 X 96 Mm 0-400 Amps, Cts, Ctr 0-400 Amps With Selector Switch - 01 No. ( D ) Busbar Alluminium 200 A Capacity Note:Panel Mounted On 45 Cm Height Pcc Platform Above Ground Level And 0.15 Below Ground Level. Last date of submission for this tender is 2022-09-13. This is a Coats And Jackets tender in Bharatpur, Rajasthan

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1html
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
Sharma infra projects pvt ltd
₹1,24,50,000.00L1
Verma constructions ltd
₹1,31,00,000.00L2
Nair engineering works
₹1,38,75,000.00L3
Iyer industrial solutions
₹1,43,20,000.00L4
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in