🎉 Your free trial plan has started. Plan will expire in 0 days

Military Engineer Services

banar, rajasthan

AOC value
₹17.05L
AOC date
16 Nov
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 16 Nov 19AOC date

Important info

Result ID
Refer Docs
Award of contract
16/11/2019
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Military Engineer Services has published Rendering Services For Operation And Maintenance Of Central Ac Plant , Including Allied Services At 3 Ac , 4 Ac And 5 Ac Plant Inside Depot Area At Aa Banar , Rendering Services For Operation/ Effective Functioning And Upkeeping Of Central Ac Plant 150 Tr Capacity With Stand By Dg Set 380 Kva And Indoor Substation With 500 Kva Transformer And Ocb Of 400 Amp Capacity , Ac Plant Comprising Of 3 Nos Compressor Unit Each Not Less Than 75 Ton Two Units To Work At A Time One Unit As Relief Cum Standby , Condensor And Chillers Water Pump Sets , Cooling Towers Two Nos , Control Panels , Make Up Tank , Chiller Water Line , Ahu And Connected Ducting System In Each Building For Storage Accn Msl Shed 1 To 5 Of 2 Ac And 3 Ac Inside Depot Area In Three Shift Per Day ( Each Shift Of 8 Hrs ) To Maintain The Desired Inside Condition Of Sheds , Security Thereof Round The Clock And Maintain Record Of Daily Operation And Upkeeping Works All As Directed By Eng-In-Charge . Note: The Operator Will Be Responsible For Running Of Fire Fighting Installations At 3 Ac Area Including Six Nos Centrifugal/Submersible Pumps Sets Of Any Capacity Including Running Of Shallow Well Submersible Pump Sets For Fire Fighting Sump As And When Required . The Operator Will Also Be Responsible For Checking Of Fire Hydrants With Users With Proper Supply Of Water To Fire Hydrants In 2 Ac , 3 Ac Area . ( 3 Ac , Ac Plant ) , Rendering Services For Operation/ Effective Functioning And Upkeeping Of Central Ac Plant 200 Tr Capacity With Stand By Dg Set 500 Kva And Indoor Substation With 630 Kva Transformer And Vcb Of 400 Amp Capacity , Ac Plant Comprising Of 3 Nos Compressor Unit Each Not Less Than 100 Ton Two Units To Work At A Time One Unit As Relief Cum Standby , Condensor And Chillers Water Pump Sets , Cooling Towers Two Nos , Control Panels , Make Up Tank , Chiller Water Line , Ahu And Connected Ducting System In Each Building For Storage Accn Msl Shed 6 To 9 Of 3 Ac Inside Depot Area In Three Shift Per Day ( Each Shift Of 8 Hrs ) To Maintain The Desired Inside Condition Of Sheds , Security Thereof Round The Clock And Maintain Record Of Daily Operation And Upkeeping Works All As Directed By Eng-In-Charge . ( 4 Ac , Ac Plant ) , Rendering Services For Operation/ Effective Functioning And Upkeeping Of Air Cooled Central Ac Plant 60 Tr Capacity With Stand By Dg Set 60 Kva And Indoor Substation With 250 Kva Transformer And Vcb Of 400 Amp Capacity , Ac Plant Comprising Of 3 Nos Compressor Unit Each Not Less Than 30 Ton Two Units To Work At A Time One Unit As Relief Cum Standby , Condensor And Chillers Water Pump Sets , Control Panels , Chiller Water Line , Ahu And Connected Ducting System In Each Building For 5 Ac Inside Depot Area In Three Shift Per Day ( Each Shift Of 8 Hrs ) To Maintain The Desired Inside Condition Of Sheds , Security Thereof Round The Clock And Maintain Record Of Daily Operation And Upkeeping Works All As Directed By Eng-In-Charge . , Rendering Services For Operation/ Effective Functioning & Up Keeping Of Static Fire Fighting Water Distribution System Of Pocket ( A ) 3 Ac , Msl Sheds Of 4Ac , Pinaka Complex , Smerch Complex , Amn Disposal Area , Akash Complex Area At Inside Depot Area Fad , Aa Banar Under Ge Banar In One Shift Of Eight Hours As Per Schedule Provided / As Directed Time To Time By Engr In Charge For Distribution Of Water And For Rectification Of Complaints In The Area . , Rendering Services Person Shall Be Liaise With Pump Houses For Smooth Functioning Of Distribution System . , Note For Item No 1 To 4 :- , ( I ) Cleaning Of Complete Ac Plant I . E Cleaning Of Chiller Unit , Pump , Motor And Pipe Lines , Electric Panels Board Surrounding Area Of Plant Daily And Cleaning Of Complete Ahu Room , Cleaning Of Supply And Return Grill , Cleaning Of Cooling Tower ( On Monthly Basis ) , ( Ii ) Monitoring And Controlling Of All Refrigent Control System To Achieve Desired Inside Temperature And Pressure Of Water And Refrigerent Gas . , ( Iii ) Monitoring And Operation Of All Ahu Connected With Ac Plant . , ( Iv ) Promptly Attending And Rectification Of Fault/Breakdown Inside And Outside Of Ac Plant As And When Occurs And Same Shall Be Intimate To Je/Age Concern . . , ( V ) Promptly Attending And Rectification Of Fault/Breakdown Inside And Outside Of Ac Plant As And When Occurs And Same Shall Be Intimate To Je/Age Concern . . , ( Vi ) Maintaining Shut Down/Break Down Records Register . , ( Vii ) Security Of Installation Round The Clock . , ( Viii ) Maintaining Records For Temperature , Pressure And Humidity Etc All As Directed . , ( Ix ) Unserviseability Of Any Part/Plant Will Be Reported Immediately To Je E/M Or Engr-In-Charge . , ( X ) Quoted Rates Are Deemed To Include Maintaining Records Of Operation , Providing Stationery Requirements For Maintaining Records Of Plants And Equipments . , ( Xi ) Contractor Should Provide Uniform And Shoes Twice During The Contract To The Employees . , ( Xii ) Contractor Quoted Rates Are Deemed To Incl Torches , Safety Equipments , Measuring Tools , Trademan Tools As Per Site Requirements . . Last date of submission for this tender is 2019-10-30. This is a Industrial Gases tender in Banar, Rajasthan

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in