🎉 Your free trial plan has started. Plan will expire in 0 days

Medical College

pbm hospital, bikaner, rajasthan

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Medical College has published Supply Of Disposable Surgical And Chemicals For Dialysis Department-1 Dialyzer With Blood Tubing Set 2 Dialyzer Should Be Synthetic Membrane(Polysulfone Or Poly Ethersulfone) nBlood Tubing Set Must Be Same Company Of Dialyzer nEffective Surface Area 1.1 Sqm 3 Dialyzer Should Be Synthetic Membrane(Polysulfone Or Poly Ethersulfone) nBlood Tubing Set Must Be Same Company Of Dialyzer nEffective Surface Area 1.3 Sqm 4 Dialyzer Should Be Synthetic Membrane(Polysulfone Or Poly Ethersulfone) nBlood Tubing Set Must Be Same Company Of Dialyzer nEffective Surface Area 1.4 Sqm 5 Dialyzer Should Be Synthetic Membrane(Polysulfone Or Poly Ethersulfone) nBlood Tubing Set Must Be Same Company Of Dialyzer nEffective Surface Area 1.5 Sqm n 6 Dialyzer Should Be Synthetic Membrane(Polysulfone Or Poly Ethersulfone) nBlood Tubing Set Must Be Same Company Of Dialyzer nEffective Surface Area 1.8 Sqm 7 Pediatric Dialyzer With Pediatric Blood Tubing 8 Dialyzer Should Be Synthetic Membrane(As Polysulfone Or Poly Ethersulfone) nBlood Tubing Set Must Be Of Pediatric Size And Same Company Of Dialyzer nEffective Surface Area 0.6 Sqm n 9 Dialyzer Should Be Synthetic Membrane(As Polysulfone Or Poly Ethersulfone) nBlood Tubing Set Must Be Of Pediatric Size And Same Company Of Dialyzer nEffective Surface Area 0.8 Sqm n 10 Double Lumen Catheter With Kit 11 Double Lumen Catheter With Kit Internal Jugular Curved/ Straight Catheter Should Be Made Of Flexible Radio Opaque Polyurethane With A Radio Opaque Tip (Easy Visualization In X Ray) nAccessory Shuold Be Provided As Contains( Catheter, Dilator, Introducer Needle Syringe, Guide Wire With Dispenser And Inj. Caps) nCatheter Should Have Usfda Approved (Certificate Must Be Enclosed.) nSize 11.5/12 Fr X 13 Cm n 12 Double Lumen Catheter With Kit Internal Jugular Curved/ Straight Catheter Should Be Made Of Flexible Radio Opaque Polyurethane With A Radio Opaque Tip (Easy Visualization In X Ray) nAccessory Shuold Be Provided As Contains( Catheter, Dilator, Introducer Needle Syringe, Guide Wire With Dispenser And Inj. Caps) nCatheter Should Have Usfda Approved (Certificate Must Be Enclosed.) nSize 8.5/09 Fr X 11 Cm n 13 Double Lumen Catheter With Kit Internal Jugular Curved/ Straight Catheter Should Be Made Of Flexible Radio Opaque Polyurethane With A Radio Opaque Tip (Easy Visualization In X Ray) nAccessory Shuold Be Provided As Contains( Catheter, Dilator, Introducer Needle Syringe, Guide Wire With Dispenser And Inj. Caps) nCatheter Should Have Usfda Approved (Certificate Must Be Enclosed.) nSize 10 Fr X 12 Cm n 14 Double Lumen Catheter With Kit Internal Jugular Curved/ Straight Catheter Should Be Made Of Flexible Radio Opaque Polyurethane With A Radio Opaque Tip (Easy Visualization In X Ray) nAccessory Shuold Be Provided As Contains( Catheter, Dilator, Introducer Needle Syringe, Guide Wire With Dispenser And Inj. Caps) nCatheter Should Have Usfda Approved (Certificate Must Be Enclosed.) nSize 11.5 X 12 Fr X 16/15 Cm n 15 Femoral Catheter Size 14 X 13.3 Cm nCatheter Should Be Made Of Flexible Radio Opaque Polyurethane With A Radio Opaque Tip(Easy Visualization In X Ray) 16 Disposable Biopsy Gun Needle Automated Spring Loaded Presterile Size 16g/18g- nNeedle Should Have US FDA Apposed (Certificate Must Be Enclosed) nIt Should Have Sample Notch Size 1.8 Cm And 1.9 Cm nIt Should Have Non Roll Handle Design. n 17 A.V Fistula Needle 18 A.V Fistula Needle 16G Rotating Wing Tuype Having Back Eye 19 A.V Fistula Needle 17G Rotating Wing Tuype Having Back Eye 20 Haemo Dialysis Solution Fluid Concentrate (Part A) 101tr With Bicarbonate Powder 2 Pkt(Part-B) 21 Haemo Dialysis Fluid Acetate Formulation 10 Ltr Jar 22 H.D Fluid High Concentrate Part A Compatible With Bibag- nCompany Must Be ISO And GMP Certified (Certificate Must Be Enclosed) n 23 Guide Wire: J/ Straight Tip nStailess Steel: Preferably Teflon Coated: 70cm Long: 0.0035 In Diameter: One End To Be Soft It Should Be Rust Proof. Two Option Should Be Available n 24 Introducer Needle 18 G Needle Should Fit Snugly With The Hub Of Syringee & It Should Be Rust Proof 25 P.D Fuids 1 Ltr- Bottle 26 Hot Sterlilzation Solution 5 Ltr Jar nSolution Should Be Effective For Cleaning Bil Film Calcium Magnesium Deposited To Reduce Haemo Dialysis Machine Breakdown And Use For Machine Disinfection n 27 P.D Catheter With Knife 28 P.D Administration Set 29 Dialyzer Repossessing Solution Cold Steriant For Dialyzer Repossessing 5 Lter Jar 30 SODIUM HYPOCHLORITE SOLOUTION:- n Concentrate in 5ltr can n 31 CITIC MONOHYDRATE:- n Concentrate in 500 gm n 32 ACETIC - ACID SOLOUTION:- n Concentrate in 5ltr can n 33 HYDROCHLORIC ACID SOLUTION:- n Concentrate in 5ltr can n 34 CITROSTERIL SOLUTION( 5Ltr):- 35 H.D. Fluid (A+B) Bicarbonate (10 Ltr.) 36 High Flux Dialyzer :- 37 Effective Surface Area - 0.9 m2 nSpecification :- n5. Dialyzer Should Be of a reputed international Make:- n6. Must be European CE From a notified body/ USFDA certified (Certificate must be enclosed) n7. Inside diameter of fiber should be 200 micro meter. n8. It should using the sterilization method of steam/Gamma. n 38 Effective Surface Area - 1.1 m2 nSpecification :- n5. Dialyzer Should Be of a reputed international Make:- n6. Must be European CE From a notified body/ USFDA certified (Certificate must be enclosed) n7. Inside diameter of fiber should be 200 micro meter. n8. It should using the sterilization method of steam/Gamma. n 39 Effective Surface Area - 1.4 m2 nSpecification :- n5. Dialyzer Should Be of a reputed international Make:- n6. Must be European CE From a notified body/ USFDA certified (Certificate must be enclosed) n7. Inside diameter of fiber should be 200 micro meter. n8. It should using the sterilization method of steam/Gamma. n 40 Effective Surface Area - 1.5 m2 nSpecification :- n5. Dialyzer Should Be of a reputed international Make:- n6. Must be European CE From a notified body/ USFDA certified (Certificate must be enclosed) n7. Inside diameter of fiber should be 200 micro meter. n8. It should using the sterilization method of steam/Gamma. n 41 Effective Surface Area - 1.7 m2 nSpecification :- n5. Dialyzer Should Be of a reputed international Make:- n6. Must be European CE From a notified body/ USFDA certified (Certificate must be enclosed) n7. Inside diameter of fiber should be 200 micro meter. n8. It should using the sterilization method of steam/Gamma. n 42 Effective Surface Area - 1.9 m2 nSpecification :- n5. Dialyzer Should Be of a reputed international Make:- n6. Must be European CE From a notified body/ USFDA certified (Certificate must be enclosed) n7. Inside diameter of fiber should be 200 micro meter. n8. It should using the sterilization method of steam/Gamma. n . Last date of submission for this tender is 2020-12-08. This is a Chemical Supply tender in Pbm Hospital, Bikaner, Rajasthan

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in