Maharana Pratap University Of Agriculture And Technology
- AOC value
- ₹25.99L
- AOC date
- 31 Mar
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- 31 Mar 22AOC date
- -Published
- -Closes
- -Bid opens
- 31 Mar 2022AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- 31/03/2022
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Maharana Pratap University Of Agriculture And Technology has published Cn Analyzer Cn Analyzer , Cn – Elemental Analyzer , Pc Controlled Elemental Analyzer With All Essential Accessories For The Quantitative Analysis Of Carbon, Hydrogen, Nitrogen And Sulfur In Solid And Liquid Samples (Example- Soil, Plants And Biomass, Organic Manure Etc.) Based On Flash Combustion Technique Followed By Gas Chromatographic/ Temperature Programmed Desorption (Tpd) Column Separation And Thermal Conductivity Detection Through Tcd Or I`R Cells. Furnace: Single Or Dual Furnace With Automatic Temperature Control Up To 1200°C. Or More. Separation System: • Combustion Gases In The Form Co2, H2o, N2 And So2 Are Separated By Means Of Onetemperature Programmed Desorption (Tpd) Column. Baseline Separation Of C From N Peak Signal Even With A Concentration Ratio Of 12000:1 Or Better Detector: Thermal Conductivity Detector Or Infra Red Or Both Measuring Range: 0 To 100% For All Elements (C, H, N, S) With The Capability Of Measuring At Least 12 Mg Absolute Carbon In Chns Mode And More Than 40 Mg In Cn Mode. Precision: <0.1 % Or Better With Certified Standards Accuracy: <0.1 % Or Better With Certified Standards System Should Have Some Important Features Such As: • Feature To Use Automatic Oxygen Dosage System For Better Combustion Of Any Sample And No Oxygen And Consumables Waste. • Automatic Leak Test. • Standby Mode For Gas, Energy And Time Savings When Instrument Is Not Under Operation. Carrier Gas: Must Have The Facility To Use Helium As Carrier Gas Analysis Time: Chn – Less Than 8 Minutes, Chns – Less Than 10 Minutes And Cn – Less Than 5 Minutes Or Better. Maximum Sample Mass: 0.2 Mg To 1000 Mg Or More. Configurations: Several Configurations Such As Chns, Chn And Cn Should Be Available For The Determination Of The Target Elements. Integrated Autosampler: • Integrated 100 Or More Position Electronic Autosampler With He-Purged Blank-Free Ball Valve Sample Injection Into The Combustion Furnace. • Pneumatic Autosampler Will Not Be Accepted Semi-Micro Balance: Elemental Analyzer Should Be Equipped With A Semi-Micro Balance (Reputed Brand) Of Sensitivity Up To 5 Places I.E. 0.01 Mg Or More. Chns Elemental Analyzer Must Be Quoted With: • Chns Analysis Kit For 1000 Analysis Including Consumables/Reagents. • One Year Of Standard Warranty. Necessary Documents: - • Catalogue In Original. • All Technical Specifications Should Be Printed On The Manufacturers Catalogue/ Data Sheet. • Please Include The List Of Minimum 10 Users Where The Instrument Is Being Used For Similar Application In India. Last date of submission for this tender is 2022-02-25. This is a Scientific Equipment tender in Bhilwara, Rajasthan
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free