🎉 Your free trial plan has started. Plan will expire in 0 days

Employees State Insurance Corporation

esic, regional office, jaipur(rajasthan), rajasthan

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Employees State Insurance Corporation has published Tender For annual maintenance contract Of Computers, Printers, Upss, Lan & Projection Items, Other Equipment ( S ) & Lan, Power Cabling & Earthing Work , ( A ) List Of Items To Be Included In Amc Only For Service Of Engineers ( These Items Are Already In Onsite Warranty Of Oem ) - , All In One Computers , Acer Computers , Canon Printers , Kyocera Printers , Ups ( 3-Kva ) Microtek , Ups ( 3-Kva ) Bpe , Small 600 Va Ups , ( B ) List Of Items To Be Included Completely In Amc ( These Items Are Not Covered In Any Warranty ) - , Windows , Host / Standalone Computers , Multi-Function , Printers , Lipi Printers ( Lmp ) , Plasma Tv , Voip Phones , Video Conference Devices , Projectors , Amplifiers , Motorized Screens , Speakers , Mikes , Public Adress System , Nodes I / O Boxes / Port , Patch Panels , Switch , Power Boxes ( Computer Power Box ) , Ups ( Apc / Emerson / Power One Other ) -1Kva To 5Kva , Earthing Maintenance , Bas / Aaadhar Devices , ( C ) List Of Items To Be Included Completely In Amc After Expiry Of Warranty As Mentioned Below ( Currently These Items Are In Warranty ( Oem ) ) , Acer Desktops-1 , Acer Desktop-2 , Small 600 Va Ups , Microtek 3 Kva Ups , Canon Printer-1 , Canon Printers-2 , Canon Printers-3 , Canon Printers-4 , Canon Printers-5 , Aio Computers-1 , Aio Computers-2 , Aio Computers-3 , Aio Computers-4 , Aio Computers-5 , ( D . ) Electrical Work , Supply & Complete Installation Of Electricity Wires ( Pvc Insulated 1100 Volt Grade Standard Copper Wires ) Inside Pvc Conduit Pipe As Per The Direction Of Competent Authority . A . Recessed Wiring With 2X ( 1X2 . 5Sqmm ) +1X ( 1X1 . 5Sqmm ) Copper Wire For Computers . , Supply & Complete Installation Of Electricity Wires ( Pvc Insulated 1100 Volt Grade Standard Copper Wires ) Inside Pvc Conduit Pipe As Per The Direction Of Competent Authority . B . Recessed Wiring With 2X ( 1X4sqmm ) + 1X ( 1X2 . 5Sqmm ) Copper Wire For Main Power Cable & 15 / 5 Amp Socket . , Supplying & Fixing Of Computer Terminal Boxes Made Of Plastic ( White Color ) Fitted With ( 3Nos . Of 6 Amp Switches + 3 Nos . 6Amp Socket ) , All Clip In As Per Direction Of Competent Authority . ( Wiring- 2X ( 1X2 . 5Sqmm ) +1X ( 1X1 . 5Sqmm ) Copper Wire ) , Supply & Fixing Of Plastic Switch Box With All Required Materials & Wiring ( 2X ( 1X4sqmm ) + 1X ( 1X2 . 5Sqmm ) Copper Wire ) To Clip In 15 / 5 Amp Socket Point Controlled By 1 No 15 Amp Switch Complete In All Respect As Per Direction Of Competent Authority . , ( E ) Earthing , Providing And Fixing Of Chemical Earth Electrode Made Out Of 50Mm Dia Class-B Asahalock ( Or Equivalent ) 2M Length With Copper Plate Made Out Of 600X600x3 . 15 Mm Tinned Copper Plate Along With One Number 40X5mm Tinned Copper Strip Grazed With The Plate Buried Vertically With Top Edge Of The Plate At A Depth Of 1500 Mm With Arrangements For Termination Of Copper Strip Of Earth Continuity Conductor Including Cost Of Charcoal , Salt Reign Soil , Water Pouring Arrangements Brick Masonry Encloser On Top With R . C . C Cover Complete With Labour And Material As Per Direction Of Component Authority . , The Earth Lead By 8Sq . Mm Pvc Single Core Cupper Wire In Gi Pipe To Connect From Earth Electrodes To Ups Outgoing Earth Bus And After Completion Of Earthing Work , Earthing Ensure Following Parameters - A . P-N=220 To 240 V B . P-E=220 To 240 V C . N-E= Less Than 2V Earthing Should Be Less Than 2V . All Earthing Work Will Be Done As Per Direction Of Competent Authority . , ( F ) Local Area Network ( Lan ) , Supply & Complete Installation Of Cat-6 Lan Cable Inside Pvc Conduit With Required Accessories ( Including Suddle , Flexible Pipe , Tie , Band Etc . ) And As Per The Direction Of Competent Authority . Note- Single Independent Conduit Pipe For Each Single Wire Is Not Required For End To End Link . We Can Carry These Wires Together Inside One Or Two Conduit Pipes After That Conduit Pipe For Single Wire Can Be Used . ( We Can Use Bus Structure For Conduit Pipe ) , Supply And Fixing Of Cat-6 Io Boxs With Cover For Lan ( Gang Box , Faceplate & Io Port Of D-Link & White Color ) ( Numbering Tag On Each Io Box And Plastic Tag Strip On Each Cable ) And As Per The Direction Of Competent Authority . , Supply And Fixing Of Patch Panel -24 Port D-Link , Supply And Fixing Of Cat-6 Patch Chord 3 Mtr Long , Supply And Fixing Of Cat-6 Patch Chord 1 Mtr Long , Supply And Fixing Of 9U Data Rack-D-Link , Supply And Fixing Of Power Extension ( 6- Socket ) Inside Rack. Last date of submission for this tender is 2020-08-06. This is a Solid And Gel Fuels tender in Esic, Regional Office, Jaipur(rajasthan), Rajasthan

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1pdf
  • Tender Document 2pdf
  • Tender Document 3html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in