🎉 Your free trial plan has started. Plan will expire in 0 days

Airports Authority Of India

jaipur airport, rajasthan

AOC value
₹1.27Cr
AOC date
23 Jul
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 23 Jul 20AOC date

Important info

Result ID
Refer Docs
Award of contract
23/07/2020
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Airports Authority Of India has published Annual Repair Maintenance Of Various E And M Installations Including Water Cooler , Fire Alarm And Fire Fighting System Of Terminal -2 Building And Ancillary Building At Jaipur International Airport ( 2020-21 ) , Providing Four Numbers Highly Skilled Manpower On All Days Including Sundays & Holidays ( Excluding Weekly Off ) For Operation & Maintenance Of All E&M Installations As Per Technical Specifications Etc . Complete As Required . , Providing Twenty Two Numbers Skilled Manpower On All Days Including Sundays & Holidays ( Excluding Weekly Off ) For Operation & Maintenance Of All E&M Installations As Per Technical Specifications Etc . Complete As Required . , Providing Fourteen Numbers Semi Skilled Manpower On All Days Including Sundays & Holidays ( Excluding Weekly Off ) For Operation & Maintenance Of All E&M Installations As Per Technical Specifications Etc . Complete As Required . , Providing Fourteen Numbers Un Skilled Manpower On All Days Including Sundays & Holidays ( Excluding Weekly Off ) For Operation & Maintenance Of All E&M Installations As Per Technical Specifications Etc . Complete As Required . , Comprehensive Maintenance Of Fire Fighting System At Terminal No . 2 Includes Hydrant Pump Set , Sprinkler Pump Set , Jockey Pump Set , Engine Operated Hydrant Pump Set , Power Cum Control Panel , Pressure Switches , Gun Metal Hydrants , Gun Metal Branch Pipe , Hose Cabinet , Fire Brigade Inlet , Fire Brigade Drawl , All Type Of Valves , Flow Switches , Flow Switch Alarm Panel , Pressure Gauge Etc . As Per Inventory Shown In Annexure-A . , Comprehensive Maintenance Of Addressable Fire Detection And Alarm System At Terminal No . 2 Includes Fire Detection Alarm Panel , Addressable Smoke Detectors , Heat Detectors , Hooters , Mannual Call Points , Weather Proof Horns , Response Indicators , Control Modules , Fault Isolators , Pa System , Amplifier Etc . As Per Inventory Shown In Annexure-B . , Half Yearly Visit Of Original Equipment Manufacturer ( Oem ) Of Intelligent Fire Detection & Fire Alarm System To Check Performance And Breakdowns Or As And When Required ( For Siemens Make Intelligent Addressable Fda System ) . , Servicing Of Engine Operated Fire Fighting Pump Set By Oem / Authorized Service Agency As Per Manufacturer Recommendation Including Replacement Of Lubricating Oil And Filters Etc . I / C B Check Of Fire Engine . , Inspection , Repairing , Servicing , Overhauling And Testing Of 800 / 1250 / 1600 / 2500 Amp Ge / C&S Make Air Circuit Breaker From The Manufacturer Or From The Authorised Service Dealer Of Manufacturer . Cost Of Spare ( If Required ) Shall Be Paid Extra By Aai . , Inspection , Repairing , Servicing , Overhauling And Testing Of Crompton Make Vacuum Circuit Breaker ( 11Kv , 800 Amps Capacity ) From The Manufacturer Or From The Authorised Service Dealer Of Manufacturer . Cost Of Spare ( If Required ) Shall Be Paid Extra By Aai . , Checking , Servicing , Callibration & Testing Of Following Protection Relays Provided On 11 Kv Vcb Breaker Panel Complete As Per Site Requirment - A ) Numerical O / C & Earth Fault Relays ( 3 O / C + 1 Ef ) - 5 Nos . B ) Master Trip Relay -5 Nos . C ) Trip Ckt Supervision Relay -5 Nos . D ) Auxilary Relay For Transformer Protect -3 Nos . E ) Aux Relay For Transformer Neutral - 3 Nos . , Ambient Noise Monitoring Of 750 Kva Dg Set From An Iso Certified Laboratory With Following Parameter:- Lday And Lnight Including Collection Of Sample From Site And Submission Of Test Report Etc . Complete As Required . , Stack Emission Monitoring Of 750 Kva Dg Set From An Iso Certified Laboratory With Following Parameters :- Pm , Sulphur Dioxide , No2 Including Collection Of Sample From Site And Submission Of Test Report Etc . Complete As Required . , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade , Rewinding Of Fan Motor Of Ceiling Fan / Wall Mounted / Exhaust Fan Etc With Enamelled Copper Wire Of Required Grade Insulation And Providing & Fixing Of Brass Bushes Including Dismantiling The Existing Fan Motor , Transportation To & Fro , Re-Installation , Testing Commissioning Etc Complete As Required . ( Dismantle Copper Wire , Bushes Etc . Need Not To Be Returned ) , Repairing & Rewinding Of 3 Phase 1 . 1 / 2 . 2 Kw Motor Monoblock / Mud Pump Set Including Replacement Of Motor Bush , Oil Seal , Bearings Etc Including Dismantiling The Existing Pump , Transportation To & Fro , Re-Installation , Testing Commissioning Etc Complete As Required . ( Dismantle Copper Wire , Bushes Etc . Need Not To Be Returned ) , Repairing & Rewinding Of 3 Phase 4 . 0 / 5 . 5 Kw Motor Monoblock Pump Set Including Replacement Of Motor Bush , Oil Seal , Bearings Etc Including Dismantiling The Existing Pump , Transportation To & Fro , Re-Installation , Testing Commissioning Etc Complete As Required . ( Dismantle Copper Wire , Bushes Etc . Need Not To Be Returned ) , Repairing & Rewinding Of 3 Phase 9 . 2 / 9 . 3 Kw Motor Monoblock Pump Set Motor Including Replacement Of Motor Bush , Oil Seal , Bearings Etc Including Dismantiling The Existing Pump , Transportation To & Fro , Re-Installation , Testing Commissioning Etc Complete As Required . ( Dismantle Copper Wire , Bushes Etc . Need Not To Be Returned ) , Repairing & Rewinding Of 3 Phase 1 . 1 / 2 . 0 Kw Motor Submersible Pump Set Motor Including Replacement Of Motor Bush , Oil Seal , Bearings Etc Including Dismantiling The Existing Pump , Transportation To & Fro , Re-Installation , Testing Commissioning Etc Complete As Required . ( Dismantle Copper Wire , Bushes Etc . Need Not To Be Returned ) , Repairing & Rewinding Of 3 Phase 5 . 0 / 7 . 5 Hp Motor Submersible Pump Set Motor Including Replacement Of Motor Bush , Oil Seal , Bearings Etc Including Dismantiling The Existing Pump , Transportation To & Fro , Re-Installation , Testing Commissioning Etc Complete As Required . ( Dismantle Copper Wire , Bushes Etc . Need Not To Be Returned ) , Lifting And Lowering Of 5 / 7 . 5 Hp Submersible Pump Set From Bore Well Upto The Depth Of 150 Meter Including Replacement Of Bolts , Gasket , Arrangement Of All Required T&P And Sundaries Etc Complete As Required , Visit Charges Of Service Engineer From Authorized Lab / Specialised Agency As Per Approval Of E-I-C For Inspection Of Sewage Treatment Plant . , Removal Of Dry Sludge From Sludge Bed Of Stp I / C Disposal The Same Outside The Airport Premises Etc As Required . , Cleaning Of All The Tank Of Sewage Treatment Plant ( I / C Collection Tank , Aeriation Tank , Chlorine Contact Tank , Filter Feed Tank , Treated Water Tank Etc . ) By Removing All The Waste Material / Sewage / Mud And Removal / Disposal Of Waste Material From The Airport Premises , Complete As Per Site Requirement . , Complete Servicing & Overhauling Of Twin Lobe Air Blower 200 M3 / Hr Capacity ( Make: Everest , Model: M5075 ) I / C Replacement Of Oil , Oil Seal , Bearing And Internal Worn Out Parts But Excluding Suction Filter Etc . Complete As Required . , Supply & Replacement Of Activated Carbon Of 800 Iv ( Iondine Value ) Grade In Activated Carbon Filter Of Stp . , Supply & Replacement Of Sand & Gravel Media Sand Filter Of Stp . , Supply Of Pressure Gauge ( Upto 14Kg / Cm2 ) . , Supply Of Liquid Chlorine ( Sodium Hypo Chloride ) . , Supply Of Jaggery ( Gud ) , Supply Of Fetilizer Di-Ammonium Phosphate ( Dap ) &Urea . , Supply Of Cow Dung . , Supply Of Tcca-90 ( Trychlo Iso Cynuric Acid ) . , Testing Of Water From The Approved Test Laboratory And Submitting The Test Reports With Following Parameters: Bod , Cod , Tss , O&G , Ph Value Etc . I / C Collecting The Sample Of Incoming Effluent / Treated Water From The Stp . , Cleaning Of The Water Body ( Fountain Tank ) And Keep It Operation By Removing All The Waste M. Last date of submission for this tender is 2020-06-13. This is a Completion Equipments tender in Jaipur Airport, Rajasthan

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

No Documents Found

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in