🎉 Your free trial plan has started. Plan will expire in 0 days

Public Health Engineer Organisation

dharamgarh, odisha

AOC value
₹14.97L
AOC date
26 Sep
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 26 Sep 25AOC date

Important info

Result ID
Refer Docs
Award of contract
26/09/2025
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Public Health Engineer Organisation has published Supply , Installation , Testing And Commissioning Of Flowmeters In Zonal Reservoirs With Other Ancillary Work In Dharamgarh Nac- 1 Supply, install and commission Electromagnetic Flow Meter(EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/- 0.5% of measured value & protection as per given specifications for size 100 mm1000mm including sensor, transm itter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM/GPRS ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications.1) The sensor should be as per IP-68 protection & with flanges of PN 10 rating from CS-1 No.2) The sensor coil housing shall be IP-68.This protected against external magnetic field.3) The transmitter shall have one current 4 m A-20 mA output.4) The current output shall be galvanically / optically isolated. transients without damage. It shall be fitted with switched mode power supply capability 85- 260 V & 45-65 Hz to cope up with power transient without damage 2 5) Signal & power cables shall be of 50 Mtrs length/each. 6) Conduit pipe ( PVC Plumbing schedule 4 ) 25 mm diameter with suitable rating of cable with digging, laying & concealed the duct - 25 mtrs/each 7) UPS working on 230 V AC, 50 Hz power supply suitable for 12 hrs continuous operation-1 No. 8) Data storage capacity with built in or separate for date time, actual flow rate, totaliser & error messages if any with storage capacity of 120 days -1 No. 9) Proper earthing shall be provided for protection against high voltage surge. 10) Suitable over voltage protection unit for protection of instrument from higher voltage (upto 275 V-300 V AC) 3 200 mm Nominal DiameterInside WTP 4 300 mm Nominal DiameterFlowmeterat Kebidi and Revenue Colony Pump House 5 350 mm Nominal DiameterFlowmeterat Intake Pump House 6 Supplying with fittings and fixing of D.I Mechanical dismentaling joint for use to main uninterrupted water supply in the pipeline in case of flowmeter as per specification and direction of Engineer-in-charge. (PN-1.6) 7 200 mm Nominal Diameter 8 300 mm Nominal Diameter 9 350 mm Nominal Diameter 10 Supplying all materials,labour and T&P and constructing brick masonry chamber as per P.H. specification and design all complete excluding RCC Cover Slab(per each) (1.20 X 1.20 X 1.00) 11 Cutting of C.I /DI pipe by eletric arc welding,at site including cost of materials,labour,T & P etc all complete 12 Level Transmitter Supply, erection, testing commissioning of ultrasonic level transmitter having a range of 0-20 mtrs with an accuracy of 10.25% of measured distance with all necessary accessores like suitable rated cable gland, blanking plug, base frame, non metallic flanges, canopy etc and other accessories required for the proper installation & functioning of level transmitter and interfacing with the proposed SCADA-PLC system. The level transmitter shall be a 2 wire system with 4-20mA analogy output and 2 nos digital out puts. The protection class of level transmitter shall be NEMA4X, IP66 at Revenue Colony pump House and Kasibahal Pump House. Make ke E&H/VEGA/SIEMENS/FORBES/MARSHALL/UWT) 13 Design, manufacture, supply,installation, testing andcommissioning of indoor type PLC panel of size approxPLC Indoor panel Made out of 2MM C.R sheet of size (1000mm X 700 mm X 1500mm floor mounted) powered coated 7 tank process with following component i.e.CPU should have 1MB program memory with extended memory slut, Redundand-24VDC, SMPS 10Amp along with 24V DC SPD,JO count as DI-20,DO-20.AI 20,AO-20 &MODBUS-10. Subsysytem shall be same series as CPU, 7inch Panel Mounted HMI, Modern should have suporrt MQTT Protocol by default, 24volt DC Industrial Switch with minium 6 eathmate. 4 SFP Port each Al shall be equiped with suitable signal isolator of 20Nos & surge protectiondevice 20nos LIU AC Isolator, 230 Volt AC/230volt torroidal transfemer, 1KVA 230V AC UPS should have capacity to Charge 3 nos 12VDC 65 AH Battery Bank, DP MCB of Adequate current capacity, Led tube light 10inch 5watt door limit switch louver, 4sqmm straighi through terminal & fuse terminal 90 nos. earthing plate(PLC- Sieemens, Schnider Phonix, ABB Mitsubishi, SMPS- Phoenix, Slemens, Schnider Isolater Masibus, Rishabh, Multispan, SPD-Phoenix, Mersen, Make Dehn UPS -Vertive. 14 supply,installation, testing and commissioning of XLPE ARMOURED Cables with COPPER Conductor 650/1100 V. Grade confirming to IS : 7098 (Pt-1) 1988 15 1.5Sqmm 10 core armoured cable 16 1.5Sqmm 3 core armoured cable 17 0.75 Sqmm2 Core armoured Screen cable . Last date of submission for this tender is 2025-08-26. This is a Flowmeters tender in Dharamgarh, Odisha

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

6 issued
  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3xlsx
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in