🎉 Your free trial plan has started. Plan will expire in 0 days

National Aluminium Company Limited

cpp, nalco, angul, odisha

AOC value
₹61.95L
AOC date
23 Mar
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 23 Mar 21AOC date

Important info

Result ID
Refer Docs
Award of contract
23/03/2021
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

National Aluminium Company Limited has published Overhauling And Maintenance Of 220Kv And 33Kv Switchyard And Transmission Line Of Cpp-Smelter , Intake Pump House And Ash Pond , 1A ) 220Kv Isolator Maintenance As Per Scope Of Work , 1B ) 220Kv Breaker Maintenance As Per Scope Of Work , 1C ( I ) Tightening Of Lightning Spike Stru , As Per Scope Of Work , 1C ( Ii ) Tightning Of Structure 22 . 5Mtr Ht , As Per Scope Of Work , 1C ( Iii ) Tightning Of Structure 17 . 5Mtr Ht , As Per Scope Of Work , 1C ( Iv ) Tightning Of Structure 13 . 0Mtr Ht , As Per Scope Of Work , 1C ( V ) Tightning Of Structure Beam10 , 13 , 17 , As Per Scope Of Work , 1C ( Vi ) Tightening Of Isolator Structure7 . , As Per Scope Of Work , 1C ( Vii ) Tightening Of Ct Structure7 . 1Mtr As Per Scope Of Work , 1C ( Viii ) Tightning Of Bus Support Insulat , As Per Scope Of Work , 1C ( Ix ) Tightening Of Pt , Cvt , La , Bkr Struct , As Per Scope Of Work , 1C ( X ) Tightening Of La Structure 10Mtr Ht , As Per Scope Of Work , 1D ( I ) Tightness Checking Of Dbl Ten Clmp , As Per Scope Of Work , 1D ( Ii ) Tightness Checking Of Sin Ten Clmp , As Per Scope Of Work , 1D ( Iii ) Tightness Checking Of Dbl Susp Cl , As Per Scope Of Work , 1D ( Iv ) Tightness Checking Of Sing Susp Cl , As Per Scope Of Work , 1D ( V ) Tightness Checking Of Pg Clmp , As Per Scope Of Work , 1D ( Vi ) Tightness Checking Of Ear Wire Ten , As Per Scope Of Work , 1D ( Vii ) Tightness Checking Of Bus Drpr Cl , As Per Scope Of Work , 1D ( Viii ) Tightness Checking Of Bus Drpr C , As Per Scope Of Work , 1D ( Ix ) Tightness Checking Of Bkr Clamp , As Per Scope Of Work , 1D ( X ) Tightness Checking Of Ct , Pt , Cvt , La , As Per Scope Of Work , 1D ( Xi ) Tightness Checking Of Wave Trap Cl , As Per Scope Of Work , 1D ( Xii ) Tightness Checking Of Spacer Clmp , As Per Scope Of Work , 1D ( Xiii ) Tightness Checking Of Bus Sup Cl , As Per Scope Of Work , 1D ( Xiv ) Tightness Checking Of Al Tube St , As Per Scope Of Work , 1D ( Xv ) 220Kv 3Ph Shorting & Normalisation , As Per Scope Of Work , 2 ( I ) Alignment Of 220Kv Isolator , As Per Scope Of Work , 2 ( Ii ) Replacement Of 220Kv Isol Polycon , As Per Scope Of Work , 2 ( Iii ) Replacement Of 70-80 Od Al Bus , As Per Scope Of Work , 2 ( Iv ) Replacement Of Equip Clmp Ct , Pt , La , As Per Scope Of Work , 2 ( V ) Replacement Of Tension Clamp , As Per Scope Of Work , 2 ( Vi ) Replacement Of Suspension Clamp , As Per Scope Of Work , 2 ( Vii ) Stringing & Restringing Of Moose C , As Per Scope Of Work , 2 ( Viii ) Replacement Of 220Kv Pg Clamp , As Per Scope Of Work , 2 ( Ix ) Replacement Of Gi Nuts & Bolts , As Per Scope Of Work , 2 ( X ) Replacement Of Wave Trap , As Per Scope Of Work , 2 ( Xi ) Installation Of Gi Strips 50X6mm Or , As Per Scope Of Work , 2 ( Xii ) Installation Of Gi Strips Above 50 , As Per Scope Of Work , 2 ( Xiii ) Repairing Of Gi Strips 50X6mm Or , As Per Scope Of Work , 2 ( Xiv ) Painting Of Pnl With Enml Paint , As Per Scope Of Work , 2 ( Xv ) Refilling Of Sf-6 Gas , As Per Scope Of Work , 2 ( Xvi ) Dcrm Testing Of 220Kv Bkr , As Per Scope Of Work , 2 ( Xvii ) Tan-Delta Testing Of 220Kv Ct , Bus , As Per Scope Of Work , 2 ( Xviii ) Crm & Timing Meas Of 220Kv Bkr , As Per Scope Of Work , 2 ( Xix ) O/H Of 220Kv Breaker , As Per Scope Of Work , 2 ( Xx ) O/H Of Abb Breaker Ventile , As Per Scope Of Work , 2 ( Xxi ) Replacement Of Abb Bkr Ventile , As Per Scope Of Work , 2 ( Xxii ) O/H Of Abb Breaker Actuator , As Per Scope Of Work , 2 ( Xxiii ) O/H Of 220Kv Iso Mech G . Box , As Per Scope Of Work , 2 ( Xxiv ) Thermography Of Swrd Clamp & Conn , As Per Scope Of Work , 2 ( Xxv ) Earth Resistans Meas Of Earth Pit , As Per Scope Of Work , 2 ( Xxvi ) Healthiness Checking Of La , As Per Scope Of Work , 2 ( Xxvii ) Stringing/Restringing Of Shld Wi , As Per Scope Of Work , 2 ( Xxviii ) String/Restringing Of Earth Wir , As Per Scope Of Work , 3 ( I ) Maint . Of 220Kv Tension Tower , As Per Scope Of Work , 3 ( Ii ) Maint . Of 220Kv Normal Tower , As Per Scope Of Work , 4 ( I ) Replacement Of 220Kv Tens Insulator , As Per Scope Of Work , 4 ( Ii ) Replacement Of 220Kv Susp Insulator , As Per Scope Of Work , 4 ( Iii ) Replacement Of 220Kv Tr Rod . , As Per Scope Of Work , 4 ( Iv ) Replacement Of 220Kv Tension Clamp , As Per Scope Of Work , 4 ( V ) Replacement Of 220Kv Susp Clamp , As Per Scope Of Work , 5 ( I ) Painting Of Single Pole Incl Supply , As Per Scope Of Work , 5 ( Ii ) Painting Of Single Pole Excl Supply , As Per Scope Of Work , 5 ( Iii ) Painting Of Dp Including Supply , As Per Scope Of Work , 5 ( Iv ) Painting Of Dp Excluding Supply , As Per Scope Of Work , 5 ( V ) Painting Of Four Pole Exc Supply , As Per Scope Of Work , 5 ( Vi ) Maint . Of Singl Pole With Cut Point , As Per Scope Of Work , 5 ( Vii ) Maint Of Singl Pole Without Cut Po , As Per Scope Of Work , 5 ( Viii ) Maint Of 33Kv Dp Structure , As Per Scope Of Work , 5 ( Ix ) Maint Of Tower In Ash Pond Line , As Per Scope Of Work , 6 ( I ) Replacement Of 33Kv Disc Insulator , As Per Scope Of Work , 6 ( Ii ) Replacement Of 33Kv Pin Insulator , As Per Scope Of Work , 6 ( Iii ) Stringing Of O/H Line With Racoon , As Per Scope Of Work , 6 ( Iv ) 33Kv Mid Span Jointing Of Racoon , As Per Scope Of Work , 6 ( V ) Erection Of 200X100mm Rs Joist Pole , As Per Scope Of Work , 6 ( Vi ) Erection Of Dp For 33Kv Line , As Per Scope Of Work , 6 ( Vii ) Dismantling Of 200X100mm Rs Joist , As Per Scope Of Work , 6 ( Viii ) Installation Of Stay Incl Supply , As Per Scope Of Work , 6 ( Ix ) Repairing Of Stay Incl Replacement , As Per Scope Of Work , 6 ( X ) Dismantling Of Existing Stay Set , As Per Scope Of Work , 6 ( Xi ) Stringing/Restringing Of Guard Wire , As Per Scope Of Work , 6 ( Xii ) Installation & Commis Of Earth Pit , As Per Scope Of Work , 6 ( Xiii ) Repairing Of Pipe Earthing , As Per Scope Of Work , 6 ( Xiv ) Erection Of Coil Earthing , As Per Scope Of Work , 6 ( Xv ) Repairing Of Coil Earthing , As Per Scope Of Work , 6 ( Xvi ) Fabrication Of Ms Angl/Chnl/Flat , As Per Scope Of Work , 7 ( I ) Replacement Of V/Straight C Arm At C , As Per Scope Of Work , 7 ( Ii ) Replacement Of V/Straight C Arm St , As Per Scope Of Work , 7 ( Iii ) Replacement Of Top Chnl At C Point , As Per Scope Of Work , 7 ( Iv ) Replacement Of Top Chnl St R Point , As Per Scope Of Work , 7 ( V ) Replacement Of Cross Arm In Dp , As Per Scope Of Work , 7 ( Vi ) Dismantling & Restringing With Raco , As Per Scope Of Work , 8 ) Maint . Of 33Kv Swrd At Cpp/Iph/Ap , As Per Scope Of Work , 9 ( I ) Replacement Of 33Kv Post Insulator , As Per Scope Of Work , 9 ( Ii ) Replacement Of 33Kv Isol M Contact , As Per Scope Of Work , 9 ( Iii ) Replacement Of 33Kv Isol F Contact , As Per Scope Of Work , 9 ( Iv ) Alignment Of 33Kv Isolator , As Per Scope Of Work , 9 ( V ) Replacement Of 33Kv Disc Insulator , As Per Scope Of Work , 9 ( Vi ) Replacement Of 33Kv Pin Insulator , As Per Scope Of Work , 9 ( Vii ) Replacement Of 33Kv St Insl Hardwa , As Per Scope Of Work , 9 ( Viii ) Dismantling Of Dog/Racoon Conduct , As Per Scope Of Work , 9 ( Ix ) Replacement Of 33Kv Clamp/Connector , As Per Scope Of Work , 9 ( X ) Replacement Of Ct/Pt/La Jn Box , As Per Scope Of Work , 9 ( Xi ) Replacement Of Surge Counter , As Per Scope Of Work , 9 ( Xii ) Replacement Of 33Kv Drop Out Fuse , As Per Scope Of Work , 10 ) Maint . Of 6 . 6Kv Vcb At Cpp & Iph , As Per Scope Of Work , 11 ) Maint . Of 6 . 6Kv Board ( Section Wise ) , As Per Scope Of Work , 12 ( A ) Maint Of 6 . 6Kv Cap Bank , As Per Scope Of Work , 12 ( B1 ) Replacement Of Capacitor Unit , As Per Scope Of Work , 12 ( B2 ) Replacement Of 6 . 6 Kv La , As Per Scope Of Work , 12 ( B3 ) Replacement Of 6 . 6Kv Neutral Ct , As Per Scope Of Work , 12 ( B4 ) Replacement Of 6 . 6Kv Clamp/Connect , As Per Scope Of Work , 12 ( B5 ) Replacement Of 6 . 6Kv Isolator , As Per Scope Of Work , 12 ( B6 ) Alignment Of 6 . 6Kv Isolator , As Per Scope Of Work , 12 ( B7 ) Replacement Of 6 . 6 Kv Pt , As Per Scope Of Work , 12 ( B8 ) Replacement O. Last date of submission for this tender is 2020-12-31. This is a Electrical Products tender in Cpp, Nalco, Angul, Odisha

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in