🎉 Your free trial plan has started. Plan will expire in 0 days

Department Of Telecommunications

khordha, odisha

AOC value
₹4.91L
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Department Of Telecommunications has published Bids Are invited for Sitc Of Inverter Split Ac Units For Bsnl Incc Bhubaneswar Supply Of 1.5Tr 5 Star Rated Copper Coil Evaporator And Copper Coil Condenser Inverter Split Ac Units - Supplying Of Bee Approved 1.5 Ton Bis Certified Wall Mounting Type Inverter -Variable Speed- Split Air Conditioning Unit Confirming To Is 1391 Part-2 Having Rated Cooling Capacity Greater Than Or Equal To 5000 Watts Rated Indian Seasonal Energy Efficient Ratio -Iseer- Wh By Wh Greater Than Or Equal To 5.60 With Copper Evaporator And Copper Condenser Coil Rotary Compressor Suitable For Operation On Single Phase 230 V Plus Or Minus 10 Percentage 50 Hz Ac Supply As Per Is 1391 Part-2 Latest And Iso 14000 Duly Filled With Ecofriendly Refrigerant Gas R32 Or Equivalent With Remote Handset Standard Lengths Of Copper Refrigerant Pipes And Foam Insulation And Drain Pipe And Interconnection Cable And Remote Hand Set With Batteries Etc. And Reusable Type Synthetic Fiber Air Filter For Indoor Unit Including All Features As Per The Detailed Specifications. The Oem Warranty Of Ac Machine Should Be 1 Year On Machine And 5 Years Warranty On Pcbs And 10 Years Warranty On Compressor. , Installation Testing And Commissioning Of 1.5 Tr Inverter Split Air Conditioning Units - Installation And Testing And Commissioning Of 1.5 Ton Or 2.0 Ton Inverter Split A.C. Unit And Mounting Or Fixing Of Indoor And Outdoor Unit And Fixing Of Refrigerant Piping With Expanded Polythene Foam Insulation Suitable Size Pvc Pipe In Wall Crossings And Laying Of Cable For Interconnections And Laying Drain Pipe Of Standard Length Which Is Supply Along With Ac Unit Minor Civil Work Including Making Holes On Wall For Laying Refrigerant Pipe Lines And Control Cable And Drain Pipes And Closing The Extra Openings And Making Good The Damages Etc. As Reqd. , Providing And Fixing Of Suitable Size L- Shaped Powder Coated Ms Bracket - Providing And Fixing Of Suitable Size L- Shaped Powder Coated Ms Bracket -2 Nos. Per Set- On Wall With Suitable Size Anchor Bolts For Fixing Of The Outdoor Unit Of The Split Ac Units Including Drilling Holes Etc. Complete As Reqd. , Providing And Laying Of Additional Refrigerant Copper Pipes For Suction And Discharge Lines Of Split Ac Units - Providing And Laying Of Additional Refrigerant Copper Pipe For Suction And Discharge Lines -Size Not Less Than One By Four Inches And Half Inches Dia Or As Recommended By The Manufacturer Along With Expanded Polythene Foam Insulation Including Cutting And Brazing And Making Joint Etc As Reqd. The Measurement Shall Be Taken On Linear Basis For One Circuit Which Includes Suction And Discharge Line And Foam Insulation. , Supplying And Laying Of 4 Core 2.5Sqmm Size Pvc Insulated And Pvc Sheathed Copper Conductor Cable - Supplying And Laying Of 4 Core 2.5Sqmm Size Pvc Insulated And Pvc Sheathed Copper Conductor Cable For Inter Connection Of Indoor And Outdoor Units Of Acs Etc As Reqd. Isi Marked. , Providing And Laying Of Additional Drain Pipe Of Size 20Mm Dia - Providing And Laying Of Additional Drain Pipe Of Size 20Mm Dia Pvc Braided Or Solid Medium Class Isi Marked Along With All Accessories And Fixing On Surface Of Wall With Pvc Saddles If Required Suitable For Drainage Of Condensate Water Etc. As Reqd. , Providing Of Additional R32 Refrigerant Gas - Providing Of Additional R32 Refrigerant Gas If Required And Charging Into The Inverter Split Ac Unit Etc. As Reqd. , Supply And Fixing Of Mcb Protected 3 Pin Socket Outlet Boxes - Supply And Fixing Of Mcb Protected 3 Pin Socket Outlet Boxes With Metal Board Consisting Of 1 No 20 S 3 Pin Socket Outlet With 20 S Plug Top And 1 No 20 Or25 S Sp Mcb Of C Series Suitable For 220-230 Volts Single Phase 50 Hz Ac Supply As Required. , Dismantling Existing Split Ac Unit - Dismantling The Existing Old And Life Expired And Faulty Sac Units Along With Indoor And Outdoor Units And Accessories And Other Unwanted Electrical Boxes Conduits Angle Iron Frames As Required. , Supply And Fixing Dlp Pvc Trunking With Cover For Drawing Refrigerant Pipes And Electrical Cables - Supplying And Fixing Of Dlp- S Universal Pvc Trunking Of Size Of 100Mm Width X 50Mm Depth With Cover Size 75Mm Width And Degree Of Protection-Ip30 With Operating Temperature -5 Degree C To 60Degree C. Rectangular White Colour On The Surface Of Wall For Drawing Refrigerant Pipes And Electrical Cables As Required. Make - Legrand Or Ss , Supply And Fixing Of Body Joint For Dlp Pvc Trunking - Supplying And Fixing Of Body Joint 100X50 And 75Mm Cover Joint For Dlp- S Universal Pvc Trunking As Required. , Supply And Fixing Of Flat Angle For Dlp Pvc Trunking - Supplying And Fixing Of Flat Angle For 100X50 Dlp- S Universal Pvc Trunking As Required. , Supply And Fixing Of Junction T For Dlp Pvc Trunking - Supplying And Fixing Of Junction - Tee- For 100X50 Dlp- S Universal Pvc Trunking As Required. Total Quantity : 278. Last date of submission for this tender is 2026-07-18. This is a Air Conditioner tender in Khordha, Odisha

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in