🎉 Your free trial plan has started. Plan will expire in 0 days

Ministry Of Health And Family Welfare

Apparel And Personal Care
neigrihms, shillong, meghalaya, meghalaya
AOC ValueRefer Docs
AOC DateRefer Docs
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
Refer Docs
Authority
Ministry Of Health And Family Welfare
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
55(00)/2025-2026/XXX/5XX
Bidding URL
https://www.exampletenders.gov.in/bid/98765
Tender
View Tender
Bidder Details
Bidder Name: Mr. Jhon Doe, Ranking 2

AOC Description

Ministry Of Health And Family Welfare has published Description Of Stores / Items: Processing Of Intra Ocular Lenses ( Iols ) , On Case To Case Consignment Basis, On Rate Contract For A Period Of 3 Years Or Till The Finalization Of The Next Tender, Whichever Is Later. For Department Of Ophthalmology - 1 Foldable Posterior Chamber Intraocular Lens ( Lens Power ) :- Nmaterial: Acrylic, Hydrophobic, Posterior Truncated Square Edge, Uv And Blue Light Filtering, Anterior Biconvex, Planar Haptics, Optic Type - Aspheric, Optic Diameter - 6Mm, Overall Length Approx. 13.0 Mm, Yellow Chromophore Is A Must, Refractive Index - Approx. 1.55, Optic Thickness Should Be Approx. <0.8Mm. Smooth On Injecting The Iol Into The Capsular Bag. No Air Bubble In The Cartridge. Should Unfold Easily Within 10 Secs. N 2 A ) +17.0 D 3 B ) +17.5 D 4 C ) +18.0 D 5 D ) +18.5 D 6 E ) +19.0 D 7 F ) +19.5 D 8 G ) +20.0 D 9 H ) +20.5 D 10 I ) +21.0 D 11 J ) + 21.5 D 12 K ) +22.0 D 13 L ) +22.5 D 14 M ) +23.0 D 15 N ) +23.5 D 16 O ) +24.0 D 17 P ) +24.5 D 18 Q ) +25.0 D 19 R ) +25.5 D 20 S ) +26.0 D 21 Foldable Pre-Loaded Iol With Delivery System ( Iol Powers ) :- Nmaterial: Acrylic, Hydrophobic, Posterior Truncated Square Edge & Anterior Biconvex, Planar Haptics, Optic Type – Aspheric, Optic Diameter - 6Mm, Overall Length Approx. 13.0 Mm, Light Filtration - Uv, Blue Light Filtering & Yellow Chromophore Is A Must, Smooth On Injecting The Iol Into The Capsular Bag. Should Unfold Easily Within 10 Seconds. Refractive Index Approx 1.55, Optic Thickness <0.8Mm, Microincision 2.2Mm Disposable Injector. Delivery System / Injector Must Be Provided. From Reputed Company N 22 +20.0 D 23 +20.5 D 24 +21.0 D 25 +21.5 D 26 +22.0 D 27 +22.5 D 28 +23.0 D 29 +23.5 D 30 +17D 31 +18D 32 +19D 33 +24D 34 +25D 35 Toric Foldable Posterior Intraocular Lens ( Lens Power ) :- Nmaterial: Foldable Toric Iols, Acrylate / Methacrylate Copolymer, Hydrophobic, Posterior Square-Edge, Biconvex, Optic-Aspheric, Optic Diameter - 6Mm, Uv-Blocking, Blue Light & Yellow Chromophore Is A Must. Ant. Surface Aspheric, Single-Piece Iol With Diffracrive, Should Also Provide: ( I ) Fixation Ring With Degree Gauge / Marker For Accurate Axis Alignment, ( Ii ) Axis Marker ( Intraoperative ) To Mark Axis On Cornea To Be Provided, Iol Cylinder Powers ( Diopters ) +1.50D To 6.00D, Smooth On Injecting The Iol Into The Capsular Bag. No Air Bubble In The Cartridge. Should Unfold Easily Within 10 Secs. N 36 +19.0D 37 +19.5D 38 +20.0D 39 +21.5D 40 +22.0D 41 +22.5D 42 +23.0D 43 +23.5D 44 Trifocal Iols: ( 1 ) High End Quality :- Nfoldable Hydrophobic ( >90% ) Acrylic Iols, 3 Focal Points, Optic Of Lens Should Have Truncated Square Edge. Refractive-Diffractive Optic, Wide Range Of Diopter 6D To 30D. Microincision 2.2Mm Disposable Catridge / Preloaded Injector. Truncated Square Edge, Optic Diameter - 6Mm, Diopter Approx - 12.5D, C-Loops Haptics, Refractive Index: Approx 1.55. Good Defocus Aspheric Surface Curve, Negligible Or No Glare, Halos Or Scattering Of Light, Should Provide Good Contrast Sensitivity, Should Provide Clear, Far, Intermediate - Near Vision, Slanted Transition Zones, Reduced Pupillary Dependence, Balanced Distribution Of Light, Able To Tolerate Some Decentration, Near Add: Approx. +2.0 Intermediate: Approx 3.50D, Uv, Blue Light Filter & Yellow Chromophore Is A Must. Smooth Injection Of Iol. Should Unfold Easily Within 10 Seconds. N 45 +19.0D 46 +19.5D 47 +20.0D 48 +20.5D 49 +21.5D 50 +22.0D 51 +22.5D 52 +23.0D 53 +23.5D 54 Trifocal Iols: ( 2 ) Under Make In India Initiative:- Nfoldable Hydrophobic ( >90% ) Acrylic Iols, 3 Focal Points, Optic Of Lens Should Have Truncated Square Edge. Refractive-Diffractive Optic, Wide Range Of Diopter 6D To 30D. Microincision 2.2Mm Disposable Catridge / Preloaded Injector. Truncated Square Edge, Optic Diameter - 6Mm, Diopter Approx - 12.5D, C-Loops Haptics, Refractive Index: Approx 1.55. Good Defocus Aspheric Surface Curve, Negligible Or No Glare, Halos Or Scattering Of Light, Should Provide Good Contrast Sensitivity, Should Provide Clear, Far, Intermediate - Near Vision, Slanted Transition Zones, Reduced Pupillary Dependence, Balanced Distribution Of Light, Able To Tolerate Some Decentration, Near Add: Approx. +2.0 Intermediate: Approx 3.50D, Uv, Blue Light Filter & Yellow Chromophore Is A Must. Smooth Injection Of Iol. Should Unfold Easily Within 10 Seconds. From Indian Company Under Make In India Initiative. N 55 +19.0D 56 +19.5D 57 +20.0D 58 +20.5D 59 +21.5D 60 +22.0D 61 +22.5D 62 +23.0D 63 +23.5D 64 Scleral Fixated Iol: Na ) Rigid, Pmma Iol, Optic Diameter - 6Mm, Eyelets For Tying Sutures, Scleral Fixated Type, Uv, Blue Light Filter &Yellow Chromophore Is A Must. N 65 +18.0D 66 + 19.0D 67 + 20.0D 68 + 20.5D 69 + 21.5D 70 + 22.0D 71 Scleral Fixated Iol ( Foldable ) :- N ( B ) Foldable Iol With Haptic Material For Making A Flange With Cautery For Yamane Technique, Optic Diameter - 6Mm, Uv, Blue Light Filter & Yellow Chromophore Is A Must. N 72 +18.0 D 73 + 19.0D 74 + 20.0D 75 + 20.5D 76 + 21.5D 77 + 22.0D 78 Phakic Iol / Intra Cameral Lens ( Icl ) :- Nintracameral Phakic Iol, Collamer / Hybrid Acrylic Material, Power Range: +15D To -30D, In 0.5D Steps, Optic Type : Aspheric Vault Height : Approx 1-1.8Mm, Overall Length Approx. 11-14 Mm ( In 0.25Mm Steps ) Adequate Number Of Holes For Aqeous Flow, Adequate Number Of Haptic Pads To Ensure Better Stability, Refractive Indx: Approx. 7.465. Delivery System Should Be Provided. 79 Scleral Fixated Iol:- Rigid, Pmma Iol, Optic Diameter - 6Mm, Eyelets For Tying Sutures, Scleral Fixated Type 80 +18.0 D 81 + 19.0D 82 + 20.0D 83 + 20.5D 84 + 21.5D 85 + 22.0D 86 Phakic Iol / Intra Cameral Lens ( Icl ) :- Intracameral Phakic Iol, Collamer / Hybrid Acrylic Material, Power Range: +15D To -30D, Adequate Number Of Holes For Aqeous Flow, Adequate Number Of Haptic Pads To Ensure Better Stability, Delivery System Should Be Provided 87 Injections: 88 Inj. Ranibizumab For Intra Vitreal Inj. 0.05Ml ( 10Mg / Ml ) - Inj. Ranibizumab 10 Mg / Ml. For Intraocular Use Only 89 Inj. Dexamethasone Implant ( Ozurdex ) 0.7Mg - Intravitreal Implant, .07 Mg Dexamethasone. Pre-Loaded Single Use.For Intraocular Useonly 90 Inj. 20% Sodium Fluosrscein Eye - Inj. 20% Sodium Fluosrscein Eye. For Fundus Fluorescein Angiography 91 Inj. Trypan Blue - Trypan Blue - 0.6 Mg, Sodium Chloride I.P - 8.2 Mg, Sterile Aqueous Base - Q.S, For Intraocular Use Only 92 Inj.Hyaluronidase 1500 ( Hyalase / Facidase ) - Each Vials Contains Hyaluronidase ( Ovine ) Ip 1500 Iu, Excipients Q.S, . For Intraocular Use Only 93 Inj. ( Hydroxypropyl Methyl Cellulose Ophthalmic. Soln. 2% ) ( Intraocular Use ) - Sterile, Isotonic, Apyrogenic Viscoelastic Sollution, Hydroxy Propyl Methyl Cellulose ( Hpmc ) Solution, High Molecular Weight. Viscosity - 4500 To 5500 Cps And The Ph Is 6.8 To 7.4. For Intraocular Use Only. 94 B-Hex Pupillary Expander With Injector - Soft Foldable Material For Expansion Of Non Dilating Pupil, Should Be Able To Go In Of ? 3 Mm Incision Size 95 Ophthalmic Viscoelastic Devices:- N Hyopt Plus Injection:- Each 0.5Ml Sodium Hyaluronate Ophthalmic Slution Contains: Na Hyaluronate Bp 11.9Mg +, Na Chloride Usp 7.20 Mg+, Di-Sodium Hydrogen Phosphate De-Hydrate Usp 0.238Mg+, Na Di-Hydrogenphosphate Ponohydrate Usp 0.034Mg+, Water For Injection Usp Q.S. N 96 Iris Hook - Flexible Iris Retractors, Disposable. Prolene Material 97 Artificial Eye Ball Implant 98 Hydro Apatite -Adult 99 Hydro Apatite -Paediatric 100 Hydro Apatite -Infant 101 Eye Shield Confromer -Infant 102 Eye Shield Confromer -Adult 103 I -Care Rebound Tonometer Disposable Probes -Disposable Probes Compatible For I-Care Rebound Tonometer. Last date of submission for this tender is 2021-08-05. This is a Coats And Jackets tender in Neigrihms, Shillong, Meghalaya, Meghalaya

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1pdf
  • Tender Document 2pdf
  • Tender Document 3html
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
Sharma infra projects pvt ltd
₹1,24,50,000.00L1
Verma constructions ltd
₹1,31,00,000.00L2
Nair engineering works
₹1,38,75,000.00L3
Iyer industrial solutions
₹1,43,20,000.00L4
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in