🎉 Your free trial plan has started. Plan will expire in 0 days

Indian Air Force

Electrical Industry
east khasi hills, meghalaya
AOC Value₹7.72 Lac
AOC DateRefer Docs
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
Refer Docs
Authority
Indian Air Force
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
Bidding URL
Tender
Bidder Details

AOC Description

Indian Air Force has published Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Defence Premise; Power Generators; Service Provider; This document covers the detailed specifications in respect of installation of 01x125 KVA DG Set. Make-Kirloskar at GES site 2. Installation with connection of fuel day tank. Provisioning of connection via fuel pipe line (diameter 1.5 inch) from fuel day tank to DG sets and return fuel pipe line (diameter 1.5 inch) from DG sets to day tank with the provision of opening and closing valve. Length of pipe line depends upon distance between day tank to DG sets. Cleaning and painting of existing metal fuel day tank with provisioning of new fuel level indicator. Facility of electrical pump to refuel the fuel day tank from barrel with electrical connections. 3. Fabrication of new AMF panel inside the canopy of DG set. Installation and fabrication of compact size AMF panel required inside the canopy of DG set with all safety features and comprehensive rewiring with updated electrical scheme adherence to ensure compliance with current standards and enhance system robustness. Luminary inspection device required to ensure proper illuminations during maintenance and operation. It provides the facility to ensure seamless automatic mains failure response. Integration of AMF panel required with another installed DG set of same rating at GES Site. 4. Alternator. Overall maintenance which include the proper functioning of AVR and rectifier assembly of alternator required as it is in idle condition since 2 years. After the maintenance insulation test to be checked by megger at 1000V. Insulation resistance should not be less than 5 Mega Ohm. Provisioning of alternator output connection with uninyvin cable to AMF panel. Provisioning of alternator space heater for safeguard of alternator insulation. Change of alternator windings if found damage. 5. Engine . The following task are required to be completed: (a) Full systematic cleaning and reconditioning of the fuel filtration system, including fuel filter, oil filter and air cleaner assembly to ensure optimal particulate separation and fluid purification. (b) Comprehensive lubrication exchange with 15 W 40 lubrication oil to enhance engine durability and performance. (c) Precision recalibration of the fuel injector pump (FIP) with injector synchrony to ensure optimal fuel atomisation and combustion efficiency. (d) Complete substitution of all hydrocarbon fluid conveyance systems. including fuel pipes and hose pipes to prevent leakage and ensure seamless operation. (e) Thermodynamic exchange unit (Radiator) comprehensive decontamination, including both chemical and mechanical washing to maintain thermal efficiency. (1) V belt changing and harmonic adjustment to ensure proper tension of drive system integrity. (g) Engine mounting isolators renewal and stabilization to mitigate vibration impact and ensure structural stability. (h) Exhaust efflux system disassembly, reassembly and thermal debris extraction to maintain exhaust flow and reduce back pressure. (1) Including all other ancillary component changing, cleaning and comprehensive rewiring of the entire engine control system to enhance operational reliability. (k) Starting battery of 12 V 150 AH should be provided. 6. Charging Alternator and Static Charger. Complete servicing alternator/static charger (electronic charger) and replacement if required. of charging 7. Starter Motor. replacement if required. Complete servicing of starter motor with starting relay and 8. Painting Complete painting of DG set with canopy inside and outside as per colour code. The grade of paint should be confirmed to IS 5:2007 Indian standard colours for ready mixed paints and enamels (Sixth revision) published by bureau of Indian Standards. S. No. Description Colour Shade 1 Outer Cover Static Camouflage Pattern 220 2 Engine OG (Olive Green) 376 3 Alternator Jasmine Yellow 536 4 Fuel Pipe Lines Fire Red 5 Oil Pipe Lines (Excluding Rubber Hoses) Leaf Brown 489 6 Water Pipe Lines (Excluding Rubber Hoses) Navy Blue 106 7 Base Plate White 8 Radiator and Exhaust Pipe Aluminium. Last date of submission for this tender is 2025-07-19. This is a Electrical Maintenance tender in East Khasi Hills, Meghalaya

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1html
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in