🎉 Your free trial plan has started. Plan will expire in 0 days

Rashtriya Chemicals And Fertilizers Limited

Chemical Oil And Gas
rcf ltd chembur, maharashtra
AOC Value₹6.17 Lac
AOC Date02 Apr 2021
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
02/04/2021
Authority
Rashtriya Chemicals And Fertilizers Limited
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
55(00)/2025-2026/XXX/5XX
Bidding URL
https://www.exampletenders.gov.in/bid/98765
Tender
View Tender
Bidder Details
Bidder Name: Mr. Jhon Doe, Ranking 2

AOC Description

Rashtriya Chemicals And Fertilizers Limited has published Notice Inviting Tender For Supply Of Ptfe Lined Pipes And Fitting For Sap Plant , Supply Material At Rcf Trombay Unit ( As Per Technical Specifications Annexure-Iii ) , Sap- Pipe ( Ptfe Lined ) Size: 8 ( 200 Nb ) End Connections: Flanged , Flat Faced . Fixed Flange On One Side & Swivel ( Loose ) Flange On Other Side Pipe:Astm A-106 Gr B Sch 40 Pipe Length Face To Face = 1250 Mm Flange Material: Astm- A 105 Flange Dimensions: As Per Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 Lining Thickness: 3 Mm Minimum . Ptfe / Pfa: Astm D -1457 Type Iii / Ii . Tests : Spark Test @ 15 Kv And Hydrotest@ 10 Kg / Cm2 Painting : External Sufaces Shall Be Epoxy Painted With Primer Of 40 Micron Dft Followed By Finish Paint ( Colour-Dark Violet ) Of 40 Micron Dft Note: 1 ) Vendor Shall Submit Test Reports / Certificates ( Hydrostatic , Electrostatic Test , External Paint Dft , Material Test Certificates ) Along With The Supply . 2 ) Packing: Flange Shall Be Closed At Both The End Suitably Before Dispatch To Avoid Damage Of The Lining . , Pipe 8In Dia Ptfe Lined . Flange To Flange Distance After Lining 1000 Mm Pipe Material: Astm A 106 Gr . B Sch 40 . Flange Material: As Per Astm A 105 , Dimensions To Ansi B 16 . 5 / Asa 150 . One Side Fix & Other Side Loose Flange . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 . Lining Thickness: 3 Mm Minimum . Fitting : Astm A234 Wpb . Ptfe / Pfa : Astm D -1457 Type Iii . Tests : 15 Kv Spark Test & 10 Kg / Cm2 Hydrotest , Sap- Pipe ( Ptfe Lined ) Size: 8 ( 200 Nb ) End Connections: Flanged , Flat Faced . Fixed Flange On One Side & Swivel ( Loose ) Flange On Other Side Pipe:Astm A-106 Gr B Sch 40 Pipe Length Face To Face = 700 Mm Flange Material: Astm- A 105 Flange Dimensions: As Per Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 Lining Thickness: 3 Mm Minimum . Ptfe / Pfa: Astm D -1457 Type Iii . Tests : Spark Test @ 15 Kv And Hydrotest@ 10 Kg / Cm2 Painting : External Sufaces Shall Be Epoxy Painted With Primer Of 40 Micron Dft Followed By Finish Paint ( Colour-Dark Violet ) Of 40 Micron Dft Note: 1 ) Vendor Shall Submit Test Reports / Certificates ( Hydrostatic , Electrostatic Test , External Paint Dft , Material Test Certificates ) Along With The Supply . 2 ) Packing: Flange Shall Be Closed At Both The End Suitably Before Dispatch To Avoid Damage Of The Lining . , Sap- Pipe ( Ptfe Lined ) Size: 8 ( 200 Nb ) End Connections: Flanged , Flat Faced . Fixed Flange On One Side & Swivel ( Loose ) Flange On Other Side Pipe:Astm A-106 Gr B Sch 40 Pipe Length Face To Face = 350 Mm Flange Material: Astm- A 105 Flange Dimensions: As Per Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 Lining Thickness: 3 Mm Minimum . Ptfe / Pfa: Astm D -1457 Type Iii . Tests : Spark Test @ 15 Kv And Hydrotest@ 10 Kg / Cm2 Painting : External Sufaces Shall Be Epoxy Painted With Primer Of 40 Micron Dft Followed By Finish Paint ( Colour-Dark Violet ) Of 40 Micron Dft Note: 1 ) Vendor Shall Submit Test Reports / Certificates ( Hydrostatic , Electrostatic Test , External Paint Dft , Material Test Certificates ) Along With The Supply . 2 ) Packing: Flange Shall Be Closed At Both The End Suitably Before Dispatch To Avoid Damage Of The Lining . , Sap- Pipe ( Ptfe Lined ) Size: 8 ( 200 Nb ) End Connections: Flanged , Flat Faced . Fixed Flange On One Side & Swivel ( Loose ) Flange On Other Side Pipe:Astm A-106 Gr B Sch 40 Pipe Length Face To Face = 450 Mm Flange Material: Astm- A 105 Flange Dimensions: As Per Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 Lining Thickness: 3 Mm Minimum . Ptfe / Pfa: Astm D -1457 Type Iii . Tests : Spark Test @ 15 Kv And Hydrotest@ 10 Kg / Cm2 Painting : External Sufaces Shall Be Epoxy Painted With Primer Of 40 Micron Dft Followed By Finish Paint ( Colour-Dark Violet ) Of 40 Micron Dft Note: 1 ) Vendor Shall Submit Test Reports / Certificates ( Hydrostatic , Electrostatic Test , External Paint Dft , Material Test Certificates ) Along With The Supply . 2 ) Packing: Flange Shall Be Closed At Both The End Suitably Before Dispatch To Avoid Damage Of The Lining . , Pfa Lined M . S . Concentric Reducer . Size : 8X6 In Flange To Flange Distance After Lining 280 Mm Flange Material: As Per Astm A 105 Dimensions To Ansi B 165 / Asa 150 . Lining: Pfa Lining As Per Astm F- 1545-95 . Lining Thickness: 3 Mm Minimum . Fitting: Astm A234 Wpb . Pfa: Astm D -1457 Type Iii . Tests : 15 Kv Spark Test & 10 Kg / Cm2 Hydrotest , M . S . Teflon Lined Concentric Reducer . Size: 6X4 In Flange To Flange Disance After Lining 230 Mm Flange Material: As Per Astm A 105 , Dimensions To Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 . Lining Thickness: 3 Mm Minimum . Fitting : Astm A234 Wpb . Ptfe / Pfa : Astm D -1457 Type Iii . Tests : 15 Kv Spark Test& 10 Kg / Cm2 Hydrotest , M . S . Teflon Lined Concentric Reducer . Size: 4X3 In Flange To Flange Disance After Lining 180 Mm Flange Material: As Per Astm A 105 , Dimensions To Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 . Lining Thickness: 3 Mm Minimum . Fitting : Astm A234 Wpb . Ptfe / Pfa : Astm D -1457 Type Iii . Tests : 15 Kv Spark Test& 10 Kg / Cm2 Hydrotest , Tee Equal 6 X6 X3 In Pfa Lined ( Perfluoro Alkoxy ) With Flat Faced Fixed Fnges . Flange To Flange Distance For 6In Flanges After Lining 406 Mm . Flnge Material: As Per Astm A 105 , Dimensions To Ansi B 16 . 5 / Asa 150 . Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 . Lining Thickness: 3 Mm Minimum . Fitting : Astm A234 Wpb . Ptfe / Pfa : Astm D -1457 Type Iii . Tests : 15 Kv Spark Test& 10 Kg / Cm2 Hydrotest , Sap- Concentric Reducer ( Ptfe Lined ) Size: 6 X 3 Dia , End Connections: Flanged , Flat Faced . Fixed Flange On One Side & Swivel ( Loose ) Flange On Other Side Reducer: Astm A234 Wpb Reducer Dimensions: As Per Ansi B16 . 9 Flange Material: Astm- A 105 Flange Dimensions: As Per Ansi B 16 . 5 / Asa 150 . Face To Face : 230 Mm Lining : Ptfe / Pfa Lining As Per Astm F- 1545-95 Lining Thickness: 3 Mm Minimum . Ptfe / Pfa: Astm D -1457 Type Iii . Tests : Spark Test @ 15 Kv And Hydrotest@ 10 Kg / Cm2 Painting : External Sufaces Shall Be Epoxy Painted With Primer Of 40 Micron Dft Followed By Finish Paint ( Colour-Dark Violet ) Of 40 Micron Dft Note: 1 ) Vendor Shall Submit Test Reports / Certificates ( Hydrostatic , Electrostatic Test , External Paint Dft , Material Test Certificates ) Along With The Supply . 2 ) Packing: Flange Shall Be Closed At Both The End Suitably Before Dispatch To Avoid Damage Of The Lining .. Last date of submission for this tender is 2020-10-30. This is a Other Adhesives And Sealants tender in Rcf Ltd Chembur, Maharashtra

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1html
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
Sharma infra projects pvt ltd
₹1,24,50,000.00L1
Verma constructions ltd
₹1,31,00,000.00L2
Nair engineering works
₹1,38,75,000.00L3
Iyer industrial solutions
₹1,43,20,000.00L4
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in