🎉 Your free trial plan has started. Plan will expire in 0 days

Mumbai Port Trust

mumbai, maharashtra

AOC value
₹20.17L
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Mumbai Port Trust has published Bids Are Invited For Supply and Delivery at site of Three Phase HT ToD Smart energy meter within built RF communication module with digital output for controls, Class 0.28 as per IS 14697, IEC 62052, Billing as per MERC latest amendment, Voltage 110V (L-L), Demand Interval 15/30 min programmable, ensure IP51, backlit LCD 6-digit Tamper legend indications, Local communication Optical port, RS 485 Port, Inbuilt RF communication module at PS-3 Transformer feeders. The meter should be able to record accurate readings as per existing set Up. coct wound type Supply and Delivery at site of HT Current Transformers (CT) suitable for metering, resin 120/5A 0.28 class accuracy, 10VA for metering and 5P10 protection class 15VA conforming to IS:2705 of 1992 (amended up to date) or with latest standards. Supply and Delivery of 6.6kV PTs, indoor type cast resin 6.6kV/110V, Class 0.28, 20 VA for metering and suitable for 6.6kV OCB type breakers, 50 Ha, breaker panel at the incoming side for energy meter reading with required wiring, mounting brackets, TP MCB for isolation, wires, etc. (Optional Item) Supply and Delivery at site of Three Phase HT ToD Smart energy meter with inbuilt RF communication module with digital output for controls, Class 0.28 as per IS 14697, IEC 62052, Billing sa per MERC latest amendment, Voltage 110V (L-L), Demand Interval 15/30 min programmable, ensure IP51, backlit LCD 6-digit Tamper legend indications, Local communication Optical port, RS 485 Port, Inbuilt RF communication module at Slo-19 Transformer feeders. The meter should be able to record accurate readings as per existing set up. Supply and Delivery at site of HT Current Transformers (CT) suitable for metering, resin cast wound type 75/5A 0.28 class accuracy, 10VA for metering and Protection class 5P10, 15VA conforming to IS:2705 of 1992 (amended up to date) or with latest standards Supply and Delivery of 6.6 kV PTs, indoor type cast resin 6.6kV/110V, Class 0.25, 20 VA for metering and suitable for 6.6kV OCB/VCB type breakers, 50 Ha, breaker panel at the incoming side for energy meter reading with required wiring, mounting brackets, TP MCB for isolation, wires, etc. (Optional Item) Supply and Delivery at site of Three Phase LT-TOD CT15A Smart energy meter with inbuilt RF communication module with digital output for controls, Class 0.58 as per IS 14697, IEC 62052, Billing as per MERC latest amendment, Voltage 240V (L-N), Demand Interval 15/30 min programmable, ensure IP51, backlit LCD 6-digit Tamper legend indications, Local communication Optical port, RS 485 Port, Inbuilt RF communication module. The meter should be able to record accurate readings as per existing cet up. Supply and Delivery at site of LT Current Transformers (CT) suitable for metering, resin cast ring type 400/5A 0.5S cla০০ accuracy, 10VA conforming to IS:2705 of 1992 (amended up to date) or with latest standards Supply and Delivery at site of Three Phase HT ToD Smart energy meter with inbuilt RF communication module with digital output for controls, Class 0.28 as per IS 14697, IEC 62052, Billing as per MERC latest amendment, Voltage 110V (L-L), Demand Interval 15/30 min programmable, ensure IP51, backlit LCD 6-digit Tamper legend indications, Local communication Optical port, RS 485 Port, Inbuilt RF communication module at Slo-12 Incomer feeder. The meter should be able to record accurate readings as per existing set up. Supply and Delivery at site of HT Current Transformers (CT) suitable for metering, resin cast wound type 75/5A 0.2S class accuracy, 10VA for metering and for protection 5P10, 15VA conforming to IS:2705 of 1992 (amended up to date) or with latest standards. Supply and Delivery of 6.6kV PTs, indoor type cast resin 6.6kV/110V, Class 0.28, 20 VA for metering and suitable for 6.6kV MOCB/VCB type breakers, 50 Hz, breaker panel at the incoming side for energy meter reading with required wiring, mounting brackets, TP MCB for isolation, wires, etc. (Optional Item) Installation, testing and Commissioning of above smart meters along with CT, PTs and training. All the accessories and miscellaneous items such as mounting accessories, cables, wires, pvc pipes, etc. shall be deemed to be included in the quoted price. Inspection, Testing, Rectification of control circuit of HTCB breakers along with providing DC supply from the existing battery charger. The job shall include repairs/replacement of relays wherever required. The control circuit shall be reinstated so as to enable tripping of breakers in event of fault/overcurrent, etc. All the material required for the subject work shall be deemed to be included within the quoted price for this item Total Quantity : 37. Last date of submission for this tender is 2025-12-18. This is a Energy Meter tender in Mumbai, Maharashtra

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in