🎉 Your free trial plan has started. Plan will expire in 0 days

Military Engineer Services

semt wing cme pune, maharashtra

AOC value
₹62.27K
AOC date
11 Nov
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 11 Nov 19AOC date

Important info

Result ID
Refer Docs
Award of contract
11/11/2019
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Military Engineer Services has published Calibration Of Equipment / Devices Of Semt Wing, Cme:- 1 Electronic Analytical Balance, Make - Anamed, Capacity 210G, L.C. 0.0001G Parameters For Calibration - Weight 2 Electronic Analytical Balance, Make - Toledo, Capacity 210G, L.C. 0.001G Parameters For Calibration - Weight 3 Electronic Balance, Make - Wenser, Capacity 100Kg, L.C. 10G Parameters For Calibration - Weight 4 Digital Electronic Oven Temp Range 300°C, L.C. ±5°C, Make - Lorence & Mayo Parameters For Calibration - Temperature 5 Digital Electronic Oven Temp Range 300°C, L.C. ±5°C, Make - Bti Parameters For Calibration - Weight 6 Muffle Furnace Temp Range O To 1200°C, L.C. ±10°C, Make - ( A ) Ultratech Parameters For Calibration - Temperature 7 Digital Electronic Bal Capacity 12 Kg, L.C. 0.1G , Make - Sansui Parameters For Calibration - Weight N 8 Oven Range 250°C, L.C. ± 1°C, Capacity 100 Ltr, Make - Aimil Parameters For Calibration - Temperature 9 Water Bath, Range Amb 100°C, Make - Remi Parameters For Calibration - Temperature 10 Ph Meter 0-14 Make - Eutech Parameters For Calibration - Ph Value 11 Repair And Calibration Of Ph Meter 0-14 Make - Cd Instrumentation Parameters For Calibration - Ph Value 12 Buoyancy Balance 15Kg, Make Aimil Parameters For Calibration - Weight 13 Buoyancy Balance 15Kg, Make Aimil Parameters For Calibration - Weight 14 Industrial Type Oven, Range Amb To 300°C, Accuracy ± 5°C, Make - Quality Parameters For Calibration - Temperature 15 General Purpose Oven, 100 Ltr Capacity Make - Raut Scientific Parameters For Calibration - Temperature 16 Water Bath, Make - Quality Parameters For Calibration - Temperature 17 Water Bath, Make - Quality Parameters For Calibration - Temperature 18 Balance Capacity 150Kg, Accuracy 20Gm, Make - Sansui Parameters For Calibration - Weight 19 Balance Capacity 150Kg, Accuracy 20Gm, Make - Ele ( Supplier - Ultra Tech ) Parameters For Calibration - Weight 20 Balance 21 Kg, Sensitivity 0.05G Make - Sansui Parameters For Calibration - Weight 21 Los Angels Abrasion Testing Machine, Nrange 20 - 33 Rpm, Accuracy ± 2 Rpm, ( Prior To 1984 ) Parameters For Calibration - Rpm 22 Los Angels Abrasion Testing Machine, Range 20 - 33 Rpm, Accuracy ± 2 Rpm, Supplier Ultra Tech Make - Control Parameters For Calibration - Rpm 23 Accelerated Curing Tank, Make - Aimil Parameters For Calibration - Temperature 24 Cleveland Open Cup Flash Point Apparatus, Make - Aimil Parameters For Calibration - Rate Of Heating 25 Electronic Balance 3 Kg, Make - Cas Parameters For Calibration - Weight 26 Electronic Balance 6 Kg, Make - Delmer Parameters For Calibration - Weight 27 Ring & Ball Apparatus, Make - Aimil Parameters For Calibration - Temperature 28 Cannon Manning Vaccum Viscometer :- Viscosity Bath Temperature Parameters For Calibration - Temperature 29 Cannon Manning Vaccum Viscometer :- Digital Timer Parameters For Calibration - Timer 30 Brook Field Viscome:- Temperature Parameters For Calibration - Temperature 31 Brook Field Viscome:- Rpm Parameters For Calibration - Rpm 32 Water Bath, Make - Equitron Parameters For Calibration - Temperature 33 Thin Film Oven ( Rotating Oven ) Parameters For Calibration -Temperature 34 Penetrometer, Make - Aimil Parameters For Calibration - Timer & Weight 35 Ductility Apparatus - Measuring Scale Parameters For Calibration - Scale 36 Electronic Balance Capacity 150Gm, L.C. 0.001G, Make - Sansui Vibra Parameters For Calibration - Weight 37 Electronic Balance Cap 15 Kg L.C. 0.5G, Make - Eagle Parameters For Calibration - Weight 38 Electronic Balance Capacity 10Kg, L.C. 0.5G Make – Wensar Parameters For Calibration -Weight 39 Electronic Balance Capacity 0 - 220G, L.C. 0.001G Make - Shinko Parameters For Calibration - Weight 40 Oven, Capacity Amb To 250°C, Make - Thermotech Parameters For Calibration - Tempatarue. Last date of submission for this tender is 2019-10-29. This is a Thinners tender in Semt Wing Cme Pune, Maharashtra

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in