Department Of Agriculture
- AOC value
- ₹8.21L
- AOC date
- 23 May
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- 23 May 23AOC date
- -Published
- -Closes
- -Bid opens
- 23 May 2023AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- 23/05/2023
- Authority
- Department Of Agriculture
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Department Of Agriculture has published Retender Of Supply Of Essential Machinery For Establishment Of Plant Leaf And Tissue Analysis Laboratory-Kjedhal Block Digester Along With Cooling Station And Fume Scrubber And Distillation Unit :- This Instrument Consist Of 3 Part = ( A ) Kjeldahl Block Digester With Cooling Station + ( B ) Fume Scrubber And ( C ) Automatic Kjeldahl Distillation Unit , And The Specification Of This 3 Parts Are Mentioned As Follows :- ( A ) Kjeldahl Block Digester With Cooling Station :- • Fast , Safe And Complete Digestion Of Samples Through Aluminiumblocks•Intricatelycontroldigestiontemperature Curves For Unsupervised Digestion. • Monitor Process Parameters & Pre-Set Samples Cycles. • Autolift Enables Complete Automation And Safety. • Cooling Stations Increase Throughput By Decreasing The Cooling Time Past Digestion. •Number Of Positions : 250 Ml X 12 Nos • Tube Capacity ( Ml ) : 250 Ml •Temperature Range : Ambient To 470°C • Timer Range : 1 To 300 Minutes • Temperature Precision : + Or - 1°C • Ramp And Hold : Upto 4 •Presets : Upto 50 • Auto Scrubber On / Off : Yes •Pid Control : Yes • Autolift : Yes • Auto Off After Achieving Set Time : Yes • Temperature Calibration : Yes , Single And Two Point • Pc & Printer Connectivity : Yes Upgradable • Display : Graphical Lcd • Body : Stainless Steel With Control Paneloffrp•Currentconsumption:8A•Dimension: 416X554x595mm • Power Consumption : 1600W • Cooling Station : Increase Sample Throughput By Saving Time On Sample Cooling • Save Time On Complete Kjeldhal Process As Cooling Station Offers Rapidsample Cooking. ( B ) Fume Scrubber:-• Transparentpc Protective Front Shield And Easy Removable Bottle Tray. • Carbon Adsorption Bottle Removal Any Trace Acid From Exhaust Air. • Fume Scrubber With 28Lpm Capacity For Complete Evacuation Of Acid Fumes. • Ptfe Air Baffle For Acid Neutralisation• 2 Litre Condensation And Neutralisation Jars For Larger Fume Volumes. • Polypropylene Head / Nozzle, Valve In Teflon & Diaphragm In Tefloncoatedneoprenerubber•Threadedtubeconnectorsfor Quick Removal Of Glass Components For Maintenance • Fume Condenser Attachment For Pre Condensation Of Excess Acid, Hence Saving Neutralisation Chemicals. • Current Consumption ( A ) :1A • Capacity :28Ltr / Min•Dimension ( Wxdxh ) Inmm : 365X375x480mm ( C ) Automatic Kjeldahl Distillation Unit : • Simple Programming And Stright Forward Operation • Quick Start Option With Favourite Method Menu • Start And Stop Cooling Water Automaticallly During The Distillation Process With Excellent Insulationofinternalparts•Robustacidresistanthousing• Compact Footprint Saves Useful Laboratory Bench Space • Brilliant Supervision Of All Crucial Functions • Comprehensive Built In Safety Systems For Operator Protection •Sample Analysis Reuires No Monitoring • The Inbuilt N / Protein Calculator With Extraction Of Results Makes The System Versatile Like Never Before • Automatic Dilution , Steam , Alkali , Acid And Test Tube Drain • Anti Corrosive Frp Body Construction • 7 Colored Touch Screen Display • Steam Regulation ( 10 To 100% ) • Process Kill Switch To Hall The Process In Caseofaccidential•Processresumefromstop•Detachable Bottom Drip Tray For Extra Protection Against Acid Attack • Anytime Alkali Addition During The Distillation Cycle • Tube Sensor That Enablessafeoperatingconditionsineventoftubedamage• Reagent Refill Level Sensor To Avert Reagent Dry Out • One Pointcalibrationofalkalianddistilledwaterpumps•Twopoint Calibrationforacidpumps•Realtimemonitoringofprocess Parameters • Selv Protection • Nitrogen Reproducibility : + Or -1% • Rsd < 1% • Lod Of 1 To 200 Mg With Greater Then Or Equalto0.1Mgof Nitrogen •Nitrogen Recovery Greater Then 99.5% •Tube Capacity ( Ml ) : 250 Ml , Minimum Distillation Time ( Mins ) : 5 , Current Consumption ( A ) : 10 , Power Consumption ( W ) : 1500, Dimension : Lenght 480 Mm X Breadth 470 Mm X 820 Mm. Last date of submission for this tender is 2023-04-28. This is a Liquid Container tender in Latur, Maharashtra
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free