Central Railway
- AOC value
- ₹5.03L
- AOC date
- 29 Sep
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- 29 Sep 26AOC date
- -Published
- -Closes
- -Bid opens
- 29 Sep 2026AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- 29/09/2026
- Authority
- Central Railway
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Central Railway has published Supply Of 1)cage cl type motor protection circuit breaker for compressor unit of current rating 10 s, 3 pole, thermal release range 7 - 10 s as per schneider catalogue no. gv2me143 (or) abb catalogue no. ms132 - 10k (or) siemens catalogue no. 3rv2011 - 1ja20make acceptable : schneider, abb, siemens only.2)cage cl type motor protection circuit breaker for ventilation fan unit 1 & 2 of current rating 4 s, 3 pole, thermal release range 2.5 - 4 s with 1 no+1 nc auxiliary contact block, as per schneider catalogue no. gv2me083 (or) abb catalogue no. ms132-4k (or) siemens catalogue no. 3rv2011 - 1ea20 make acceptable : schneider, abb, siemens only.3)motor protection circuit breaker for water pump 1 & 2, 3 pole, adjustable thermal release range 1.1 - 1.6 s, complete with 1no + 1nc auxiliary contact, as per schneider electric catalogue no. gv2me06 + gvae11 (or) abb catalogue no. ms132 (1.0-1.6 a) + hk1-11 (or) siemens catalogue no. 3rv2011-1aa20 + 3rv2901-2e.acceptable makes: schneider, abb, siemens only.4)cage cl type motor protection circuit breaker for condenser fan motor of current rating 2.5 s, 3 pole, thermal release range 1.6 - 2.5 s as per schneider catalogue no. gv2me073 (or) abb catalogue no. ms132-2.5k (or) siemens catalogue no. 3rv2011 - 1ca20 make acceptable : schneider, abb, siemens only. , cage clamp type motor protection circuit breaker for compressor unit of current rating 10 amps, 3 pole, thermal release range 7 - 10 amps as per schneider catalogue no. gv2me143 (or) abb catal ogue no. ms132 - 10k (or) siemens catalogue no. 3rv2011 - 1ja20make acceptable : schneider, abb, siem ens only. [ warranty period: 30 months after the date of delivery ] ] , cage clamp type motor protection circuit breaker for ventilation fan unit 1 & 2 of current rati ng 4 amps, 3 pole, thermal release range 2.5 - 4 amps with 1 no+1 nc auxiliary contact block, as per sch neider catalogue no. gv2me083 (or) abb catalogue no. ms132-4k (or) siemens catalogue no. 3rv2011 - 1 ea20 make acceptable : schneider, abb, siemens only. [ warranty period: 30 months after the date of de livery ] ] , motor protection circuit breaker for water pump 1 & 2, 3 pole, adjustable thermal release ran ge 1.1 - 1.6 amps, complete with 1no + 1nc auxiliary contact, as per schneider electric catalogue no. gv 2me06 + gvae11 (or) abb catalogue no. ms132 (1.0-1.6 a) + hk1-11 (or) siemens catalogue no. 3rv201 1-1aa20 + 3rv2901-2e. acceptable makes: schneider, abb, siemens only. [ warranty period: 30 months after the date of delivery ] ] , cage clamp type motor protection circuit breaker for condenser fan motor of current rating 2 .5 amps, 3 pole, thermal release range 1.6 - 2.5amps as per schneider catalogue no. gv2me073 (or) abb c atalogue no. ms132-2.5k (or) siemens catalogue no. 3rv2011 - 1ca20 make acceptable : schneider, abb, siemens only. [ warranty period: 30 months after the date of delivery ] ]. Last date of submission for this tender is 2026-09-21. This is a Circuit Breakers tender in Nagpur, Maharashtra
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free