Nagar Palika Nigam
- AOC value
- ₹10.68L
- AOC date
- 16 Aug
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- 16 Aug 24AOC date
- -Published
- -Closes
- -Bid opens
- 16 Aug 2024AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- 16/08/2024
- Authority
- Nagar Palika Nigam
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Nagar Palika Nigam has published Tender For Extension Of Lt 11 Kv Dhonga Trenching Ground At Nagar Palika Parishad Tikamgarh--- 1 Construction Of Electrical Pole Shifting 2 H- Beam 13 Meter 152 X 152Mm 37.1 Kg / Meter 3 11 Kv V Cross Arm 65X65x6mm. Angle Type 4 Back Clamp For H Beampole Of 65X8mm Ms Flat 5 Earthing Coil Of 115 Turns Of 50 Mm.Dia And 2.5 Mtr Lead Of 4.0 Mm G.I Wire 6 11 Kv, 5Kn Pin Composite Polymer Insulator 7 Aaac Dog Conductor 0.10 Sq. Inch ( 100 Sq.Mm. Al.Eq. ) 8 Jointing Sleeves ( Aluminium ) For Dog Conductor 9 Stay Set 20 Mm Complete 10 Stay Gi Wire 7 / 4.00 Mm. ( 7 / 8 Swg ) 11 H.Beam Clamps 65X8mm Flat 12 Stone Block / Rcc Base Plate Size 450X450x75 Mm ( 3 No Per Stay & 1 No Per Pole For Base Padding As Per Drawing No.Discom / Ez / 47 & 48 ) 13 Concreting ( 1:3:6 ) Of H- Beam @ 0.65 Cmt.Per Pole ( Base Pedding + Muffing ) 14 Concreting ( 1:3:6 ) Of Stay @ 0.3 Cmt. Per Stay ( 20Mm ) 15 Red-Oxide Paint 16 Aluminum Paint 17 Anti Climbing Device ( Barbed Wire 3.5 Kg ) Gs 2.5 Mm Dia ( 12 Swg ) 18 Danger Board Enameled 11 Kv 19 Aluminium Binding Wire And Tape 20 M S Bolt With Nut 16X140 Mm 21 R S Joist 9.3 Meter 175X85mm 22 Tension Clamp For Deadend For Lt A.B Cable 23 Suspension Clamp For Lt Ab Cable 24 Clamps For Neutral 25 Piercing Connector Type-I, 1P / 3P ( Main 16-50Sqmm Tap- Off 16-50Sqmm 26 Piercing Connector Type- Ii ( Main 16-50 Sqmm Tap-Off 16-50 Sqmm ) 27 Lt Xlpe Air Bunch Cable 3X95 Sqmm + 1X50 Sqmm Insulated Neutral Cum Messenger+1X16 Sqmm 28 Stay Set 16 Mm Complete 29 Stay Wire 7 / 3.15 Mm. ( 7 / 10Swg ) 30 Stay Clamp B Type For R.S.Joist 125X70 Mm 31 Stone Block / Rcc Base Plate Size 450X450x75 Mm ( 3 No Per Stay & 1 No Per Pole For Base Padding As Perawingno.Discom / Ez / 47 & 48 ) 32 Concreting Of For Poles @ 0.25 Cmt. For Pole ( Including Muffing ) 33 Concreting ( 1:3:6 ) Of Stay @ 0.2 Cmt. Per Stay ( 16Mm ) 34 M S Bolt With Nut 16X140mm 35 Earthing Coil Of 115 Turns Of 50 Mm.Dia And 2.5 Mtrlead Of 4.0 Mm G.I Wire 36 Spring Loaded Busbar System Suitable For 1Incoming 6 Outgoing 1 - Phase Circuit 37 Spring Loaded Busbar System Suitable For 1 Incoming 3 Outgoing 3 -Phase Circuit 38 100 Kva, Bis Certified, Level-Ii Tranformer 39 Dc.Cross Arms 8` ( 2.4Meter ) Centre To Centre 100X50x6 Mm Channel 40 Back Clamp For H Beam Pole Of 65X8mm Ms Flat 41 11 Kv, 45 Kn Disc T&C Composite Polymer Long Rod Insulator 42 11 Kv Strain Hardware ( T&C Type ) Fittings 43 Galvanised D.O.Mounting Channel 75X40x6mm 44 H.Beam Clamps 65X8mm Flat 45 Do Fuse Unit Complete -11Kv 46 11 Kv, La Polymer Type Gapless / Metal Oxide 9 Kv , 5 Ka Line Type 47 Transformer Mounting Channel 100X50x6mm 48 Transformer Clamping Set 50X50 X6 Mm Angle 460Mm Long 49 Ransformer Belting Set 50X50x6mm Angle With Two Cross Fixing Channel 50 Stay Set Without Staywire 16 Mm. ( Painted ) 51 Stay Wire 7 / 3.15 Mm. ( 7 / 10Swg ) 52 Concreting ( 1:3:6 ) Of H- Beam @ 0.65 Cmt.Per Pole ( Base Pedding + Muffing ) 53 Concreting ( 1:3:6 ) Of Stay@ 0.2 Cmt. Per Stay ( 16Mm ) 54 Aaac Rabbit Conductor0.05 Sq. Inch ( 55 Sq.Mm. Al.Eq. ) 55 Danger Board Enameled 11Kv 56 Gi Earthing Rod , 20 Mm Dia, 2000 Mm. Long 57 Anti Climbing Device ( Barbed Wire 3.5 Kg ) Gs 2.5Mm Dia ( 12 Swg ) 58 Red-Oxide Paint 59 Aluminum Paint 60 M S Bolt With Nut 16X250mm 61 M S Bolt With Nut 16X200mm 62 M S Bolt With Nut 16X140mm 63 M S Bolt With Nut 16X90 Mm 64 M S Bolt With Nut 16X65 Mm 65 M S Bolt With Nut 12X140mm 66 Distribution Box Mounting Channel ( 75X40x6 Mm. ) 67 L.T.Distribution Box For 100 Kva Transformer ( 200 A. Isolator & 6 Sp Mccb Of 90 A. ) 68 Xlpe Lt 1 - Core Aluminiumunarmoured 70 Sqmm Cable 69 Xlpe Lt 1 - Core Aluminiumunarmoured 150 Sqmm Cable 70 11 Kv Ab Switch Three Phase 600 Amp Tp Gangoperated 71 Lt Trivector Energy Meter, Dlms Compliant Category-A ( For Substation / Feedermetering ) , 3 Phase 4 Wire, 440 Volts, 5 Amp, Accuracy Class 0.5S With Gsm ( Gprs Compatible ) Modem With Box 72 H- Beam 13 Meter 152 X 152 Mm 37.1 Kg / Meter 73 11 Kv Guarding Channel 75X40x6 Mm 74 G.I. Wires 4.0 Mm. ( 8 Swg ) 75 G.I. Wires 5.0 Mm. ( 6 Swg ) . Last date of submission for this tender is 2023-08-26. This is a Electrification Work tender in Tikamgarh, Madhya Pradesh
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
5 issued- Tender Document 1xlsxXLSX document
- Tender Document 2pdfPDF document
- Tender Document 3htmlHTML document
- Tender Document 4pdfPDF document
- Tender Document 5pdfPDF document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free