🎉 Your free trial plan has started. Plan will expire in 0 days

Medical College

joint director and superintendent medical college, madhya pradesh

AOC value
₹5.69K
AOC date
19 May
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 19 May 23AOC date

Important info

Result ID
Refer Docs
Award of contract
19/05/2023
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Medical College has published Supply Of Arthoscopy Products Ortho Implants-1.01 Interference Screw All Size 1.02 Interference Bio Screw All Size 1.03 Fixed Loop Endobutton All Size 1.04 Adjustable Loop Button 1.05 Suture Disc & Merelence Tape 1.06 Meniscal Repair Implant All Inside Techniuqe - ( All Inside Meniscal Repair System With Pre Knotted 2 Peek Implants Mounted On A Straight Rigid Needle And Can Be Deployed In The Meniscus At Any Angle. It Should Gave An Inbuilt Depth Penetration Limiter To Prevent The Posterior Capsule 1.07 Meniscal Repair Imnplant All Inside Technique ( All Inside Meniscal Repair System With Pre Knotted 2 Peek Implants Mounted On A Curved Rigid Needle And Can Be Deployed In The Meniscus At Any Angle. It Should Gave An Inbuilt Depth Penetration Limiter To Prevent The Posterior Capsule Meniscal Repair Implant All Inside Technique ( All Inside Meniscal Repair 1.08 System With Pre Knotted 2 Peek Implants Mounted On A Reverse Curved Rigid Needle And Can Be Deployed In The Meniscus At Any Angle. It Should Grave And Inbuilt Depth Penetration Limiter To Prevent Posterior Capsule 1.09 Knot Pusher / Cutter For The Left Behind Suture In The All Inside Meniscal Repair System 1.1 Suture Anchors For Bankart Repair ( 2.8Mm Titanium Screw In Anchors With High & Low Threads Design, Preloaded With Single Ultrahigh Molecular Weight Polythylene Braided Fiber For Bankart / Slap Repair 1.11 Suture Anchors For Bankart Repair ( 3.5Mm Titanium Screw In Anchors With High & Low Threads Design, Preloaded With Single Ultrahigh Molecular Wiehgt Polythylene Braided Fiber For Bankart / Slap Repair 1.12 Suture Anchors For Bankart Repair - 2.3 Mm Peek Tap In Anchors, Preloaded With Single Ultrahigh Molecular Weight Polythylne 1.13 Suture Anchors For Bankart Repair - 2.3 Mm Biobsorbable ( 75% Plla & 25% Ha ) Tap In Anchors, Preloaded With Single Ultrahigh Molecular Weight Polythylene Braided Fiber For Bankart / Slap Repair Suture Anchors For Bankart Repair - 2.9Mm Biobsorbable ( 75% 1.14 Plla & 25% Ha ) Tap In Anchors, Preloaded With Single Ultrahigh Molecular Weight Polyethylene Braided Fiber For Bankart / Slap Repair 1.15 Suture Anchors For Bankar Repair - 1.7Mm All Sture Tap In Anchor Made Up Of High Molecular Weight Polythylene Braided Fibre & Preloaded With Single Ultrahigh Molecular Weight Polythylene Braided Sutures Which Opens Up To 3Mm Post Deployment With Special Deployment Mechanism Through Unique Visual Tactile & Auditory Cues Indended For Instability Repair. 1.16 Sutre Anchors For Bankart Repair - 1.9Mm All Suture Tap In Anchor Made Up Of High Molecular Wiehgt Polyethylene Braided Fibre & Preloaded With Single Ultrahigh Molecular Weight Polyethylene Braided Sutures Which Opens Up To 3Mm Post Deployment With Special Deployment Mechanism Through Unique Visual Tactile & Auditory Cues Intended To Instabilty Repair 1.17 Suture Anchor For Rotator Cuff Repair ( 5.0Mm Titanium Screw In Anchors With High & Low Threads Design, Preloaded With Double Ultrahigh Molecular Weight Polyethylene Braided Fiber For Rotator Cuff Repair. 1.18 Suture Anchor For Rotator Cuff Repair ( 6.5Mm Titanium Screw In Anchors With High & Low Threads Design, Preloaded With Double Ultrahigh Molecular Weight Polyethylene Braided Fiber For Rotator Cuff Repair Suture Anchor For Rotator Cuff Repair ( 4.5Mm Peek Tap In 1.19 Preloaded At Distal End Of The Anchor With Double Ultrahigh Molecular Weight Polyethylene Braided Fiber For Rotator Cuff Repair 1.20 Suture Anchor For Rotator Cuff Repair ( 5.5Mm Peek Tap In Preloaded At Distal End Of The Anchor With Double Ultrahigh Molecular Weight Polyethylene Braided Fiber For Rotaor Cuff Repair ) 1.21 Suture Anchor For Rotator Cuff Repair ( 4.5Mm Bioabsorbable ( 75% Plla & 25% Ha ) Tap In Anchors, Preloaded At Distal End Of The Anchor With Double Ultrahigh Molecular Weight Polyethylene Braided Fiber For Rotator Cuff Repair 1.22 Suture Anchor For Rotator Cuff Repair ( 5.5Mm Bioaborbable ( 75% Plla & 25% Ha ) Tap In Anchors, Prelaoded At Distal End Of The Anchor With Double Ultrahigh Molecular Weight Polyethylene Braide Fiber For Rotator Cuff Repair 1.23 Suture Anchor For Rotator Cuff Repair ( 6.5Mm Bioabsorable ( 75% Plla & 25% Ha ) Tap In Anchors, Preloaded At Distal End Of The Anchor With Double Ultrahigh Molecular Weight Polyethylene Braided Fiber For Rotator Cuff Repair 1.24 Suture Anchor For Rotator Cuff Repair ( 5.5Mm Bioabsorbable ( 75% Plla & 25% Ha ) Tap In Anchors, Preloaded At Distal End At The Anchor With Triple Ultrahigh Molecular Weight Polyethylene Braided Fiber For Rotator Cuff Repair 1.25 Suture Anchor For Rotator Cuff Repair ( 4.5Mm Peek Screw In Anchors, Preloaded With Double Ultrahigh Molecular Weight Polythylene Braided Fiber With Unique Open Architectural Design Allows For Bone To Interdigitate Within The Anchor Thread Profile And Achieve Excellent Fixation Secuirty Available In Double Loaded Ultraihigh Molecular Weight Polyethylene Braided Fiber For Rotator Cuff Repair 1.26 Suture Anchor For Rotator Cuff Repair ( 4.0Mm Peek Screw In Anchors, Preloaded With Double Ultrahigh Molecular Weight Polythylene Braided Fiber With Unique Open Architectural Design Allows For Bone To Interdigitate Within The Anchor Thread Profile And Achieve Excellent Fixation Security Available Double & Triple Loaded Ultrahigh Molecular Weight Polyethylene Braided Fiber For Rotator Cuff Repair 1.27 Suture Anchor For Rotator Cuff Repair ( 5.55Mm Tap In Peek Knorless Lateral Row Anchor With Offset Barbed Geometry Threads & Inner Plug Design To Provide More Precise Fixationa Nd Suture Tensioning Of Final Repair. Last date of submission for this tender is 2020-02-28. This is a Medical Equipment tender in Joint Director And Superintendent Medical College, Madhya Pradesh

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

7 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in