🎉 Your free trial plan has started. Plan will expire in 0 days

Madhya Pradesh Power Transmission Company Limited

132 kv ss borgaon, madhya pradesh

AOC value
₹3.21L
AOC date
28 Sep
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 28 Sep 19AOC date

Important info

Result ID
Refer Docs
Award of contract
28/09/2019
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Madhya Pradesh Power Transmission Company Limited has published Construction Of 1 No . 33Kv Feeder Bay And 1 No . 33Kv Bus Coupler Bay At 132 Kv Ss Borgaon Under Testing Dn . Chhindwara , Erection Of Structures Including Shifting Within Sub-Station Premises , Fixing And Alignment Of Templates For Grouted / Bolted Type Structures Foundations , Tightenning Of Nuts , Bolts , Washers Etc And Including Alignment And Levelling Of Structures . , Single Zebra Acsr Conductor , Stringing Of Overhead Shield Wire With 7 / 3 . 66Mm Standard Galvanised Steel Complete With Fixing Of Strain Clamps At The Structures . , Shifting Of 33Kv Circuit Breakers ( 3 Phase ) Within Sub-Station Premises And Placment Of C . B . On Structure . Complete Assebly Of C . B Including Erection Of Control Cabinet And Machanism Box . Erection Of All Accessories For The Equipment , Shifting Upto Civil Foundation And Placement Of Complete 33 Kv Isolator Without Earth Switch ( 3Phase ) In All Three Phase Of Isolator Structure Errction / Mounting Of Mechanism Box , Interconnection Pippnig Alignment Of Contacts And All Associated Activities To Make The Installtion Complete Including Checking Of Successful Technical And Electrical Operation . , Shifting Upto Civil Foundation And Placement Of Complete 33 Kv Isolator With Earth Switch ( 3Phase ) In All Three Phase Of Isolator Structure Errction / Mounting Of Mechanism Box , Interconnection Pippnig Alignment Of Contacts And All Associated Activities To Make The Installtion Complete Including Checking Of Successful Technical And Electrical Operation . , Shifting Of 33Kv Current Transformer ( 400-200 / 1-1 Amp ) Upto Civil Foundation And Placement On Stucture And Fixing Of Junction Box , Including All Accessories , Making All Jumpers Etc . , Shifting Of 33Kv Current Transformer ( 1200 / 1-1-1-1 Amp ) Upto Civil Foundation And Placement On Stucture And Fixing Of Junction Box , Including All Accessories , Making All Jumpers Etc . , Shifting Up To Control Room ( Including Storage If Required ) & Placment Complet With All Relays And Accesories . The Placment Of Control & Realy Panel ( 3 Feeder Circuit ) To Be Done On Ms Channel Frame And Ms Channel Frame Will Be Suitably Grouted In Conrole Room As Per Drawing . Proper Alignment Of C&R Panel To Be Done . The Earthing Of C&R Panel To Be Done . , Shifting Of 33Kv Surge Lighting Arrester And Placement On Stucture And Fixing Of All Accessories , Making All Connections , Checking And Installation Of Insulator Base And Surge Counters , Making All Jumpers Etc . , Erection Of 33Kv P . I . And Their Connections , Laying Of Copper Cables 4Core X 2 . 5 Sq . Mm ( Armoured / Unarmoured ) On Racks / Angles Support Over Head Racks , Conduits Including Dressing Of Cables With Accessories , Laying Of Copper Cables 8Core X 2 . 5 Sq . Mm ( Armoured / Unarmoured ) On Racks / Angles Support Over Head Racks , Conduits Including Dressing Of Cables With Accessories , Laying Of Copper Cables 12Core X 2 . 5 Sq . Mm ( Armoured / Unarmoured ) On Racks / Angles Support Over Head Racks , Conduits Including Dressing Of Cables With Accessories , Providing Holes 2Core X 2 . 5 Sq . Mm For Cable Entry , Fxing Of Glands , Dressing Of Cable Leads , Fixing Of Tags , Providing Holes 4Core X 2 . 5 Sq . Mm For Cable Entry , Fxing Of Glands , Dressing Of Cable Leads , Fixing Of Tags , Providing Holes 8Core X 2 . 5 Sq . Mm For Cable Entry , Fxing Of Glands , Dressing Of Cable Leads , Fixing Of Tags , Providing Holes 12Core X 2 . 5 Sq . Mm For Cable Entry , Fxing Of Glands , Dressing Of Cable Leads , Fixing Of Tags , Earthing Installation 25 Mm Dia X 3000Mm Long M . S . Rod Earth Electrodes Installation Directly Driven / Drilled ( 40 To 50 Mm Dia ) Into Earth Including Excavation ( Irrespective Of Type Of Soil Encountered ) , Backfilling With Bentonite Soil ( To Be Arranged By Contractor ) Welding To Earth Conductor Etc . , Providing Of M . S . Flat 65 X 8 Mm Risers And Making Of Earth Mat ( Duly Buried At A Depth Of 0 . 5 Meter ) Including Backfilling With Black Cotton Soil ( Soil To Be Arranged By The Contractor ) Welding Etc . And Bolting Of Riser To The Structures And Equipments , Providing Of M . S . Flat 50 X 6 Mm Risers And Making Of Earth Mat ( Duly Buried At A Depth Of 0 . 5 Meter ) Including Backfilling With Black Cotton Soil ( Soil To Be Arranged By The Contractor ) Welding Etc . And Bolting Of Riser To The Structures And Equipments , Preparation Of Earthing Pits ( 1 . 5 X 1 . 5 X 3 Meter ) As Per Approved Drawing Which Includes Excavation ( Irrespective Of The Soil Encountered ) , Embedding Of 4 Nos Gi Pipes Of Size 40 Mm Dia 3 Meter Long , Backfilling With B . C . Soil ( Soil To Be Arranged By Contractor ) Free From Boulders And Harmful Mixture . These Gi Pipes Are To Be Welded With M . S . Flats By Making Mesh Frame And Cutting Of Pipes As Also Making Holes In The Pipe For Water Seepage . The Earth Pit Is To Be Connected With Earth Mesh By M . S . Flat .. Last date of submission for this tender is 2019-08-14. This is a Angle tender in 132 Kv Ss Borgaon, Madhya Pradesh

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in