🎉 Your free trial plan has started. Plan will expire in 0 days

Madhya Pradesh Power Generating Company Limited

dongalia, madhya pradesh

AOC value
₹4.7L
AOC date
20 May
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 20 May 25AOC date

Important info

Result ID
Refer Docs
Award of contract
20/05/2025
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Madhya Pradesh Power Generating Company Limited has published Procurement Of Different Rating Control Transformers For 2X600 Mw, Sstpp, Mppgcl, Dongalia. , Control Transformer Of 5000Va Rating- 5000 Va Primary Volt- 440± 10% Secondary Volt- 240 Vregulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Lighting Transformer Of 3000Va Rating- 3000 Va, 3 Phase Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 440, Tapes At ± 2.5%, 5%, Type- An, Vector Group :- Dyn11 Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Service Building Chiller Control Transformer Of 2000 Va Rating- 2000 Va Primary Volt- 440± 10% Secondary Volt- 0-220 V & 0-220 V Secondary 1: 0-220 V ( 1.5A ) Secondary 2: 0-220V ( 7.0A ) Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Lt Buses Control Transformer Of 2000Va Rating- 2000 Va Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 240 Vac, Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Tg Eot Control Transformer Of 2000Va Rating- 2000 Va, Insulation Class F Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 110 Vac, 18.50Aregulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Cw Eot Control Transformer Of 1200Va Rating- 1200 Va, Insulation Class F. Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 110 Vac, 11A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Esp Rcp Control Transformer Of 1000Va Rating-1000 Va.Insulation Class F. Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 230-240 Vac, 4.2A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , St & Ut Oltc Control Transformer Of 500Va Rating- 500 Va, Insulation Class F. Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 55-0-55 Vac, 4.5A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Esp Ecp Control Transformer Of 500 Va Rating- 500 Va Primary Volt- 440± 10% Secondary Volt : -250 V Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Restistance Should Be More 50M Ohm , Condenser Mcc Control Transformer Of 400Va Rating- 400 Va, Insulation Class F. Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 230-240 Vac Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Esp Eot Control Transformer Of 300Va Rating. Rating- 300 Va Primary Volt- 415 ± 10%, 50Hz Secondary Volt- 110 Vac, 2.7A Type- An, Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Restistance Should Be More 50M Ohm , Wtp & Chlorination Hoist Control Transformer Of 300 Va Rating- 300 Va, Primary - 440V± 10%, 0.68A Secondary: -250 V, 2.68A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Restistance Should Be More 50M Ohm , Esp Ecp Control Transformer Of 250 Va Rating. Rating- 250 Va Primary - 440V± 10%, 0.73A Secondary: -250 V, 2.73A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Compressor , Dm , Rwis, Esp, Fire, Tac & Mill Hoist Control Transformer Of 250 Va Rating. Rating- 250 Va Primary - 440V± 10%, 0.73A Secondary: -110 V, 2.73A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Esp Rapcon Control Transformer Of 250Va Rating- 250 Va, Insulation Class F. Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 24 Vac, 10.5A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Rwph & Filter Building Hoist Control Transformer Of 200 Va Rating. Rating- 200 Va Primary - 440V± 10%, 0.48A Secondary: -110 V, 1.81A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Silo Modules Control Transformer Of 140Va Rating- 140 Va Primary Volt- 0 / 400 / 440 / 460, 50Hz Secondary Volt- 0 / 24 / 110 / 220 Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Naoh Dosing Panel Control Transformer Of 100Va Rating. Rating- 100 Va Primary Volt- 415 ± 10%, 50Hz Secondary Volt- 230-240 Vac, 0.50A Type- An, Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Esp Control Transformer Of 100 Va Rating- 100 Va Primary Volt- 440± 10% Secondary Volt- 24 V & 18 V Secondary 1: 0-24 V ( 3.2A ) Secondary 2: 0-18V ( 1.2A ) Type-An Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm. Last date of submission for this tender is 2023-01-23. This is a Lifting Equipment tender in Dongalia, Madhya Pradesh

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

7 issued
  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3xlsx
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in