🎉 Your free trial plan has started. Plan will expire in 0 days

Madhya Pradesh Power Generating Company Limited

betul, madhya pradesh

AOC value
₹23.08L
AOC date
13 Sep
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 13 Sep 25AOC date

Important info

Result ID
Refer Docs
Award of contract
13/09/2025
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Madhya Pradesh Power Generating Company Limited has published Procurement Of Various Types Of Gauges For Imd-Ivstps, Mppgcl, Sarni. , Pressure Gauge With Chemical Sealdial Size:- 150 Mm (6), Mounting:- Direct Bottom Entry Case And Bezel- Ss 304 Bayonet Lock Type,Weatherproofto Ip-68 As Per Iec:60529 Or Equivalent Dial:- Aluminium White With Black Numerals, Window:- Shatterproof Glass, Bourdon Tube Material:- Ss 316 L, Socket Material:- Ss 316 L, Movement Material:- Ss 316, Joints :- Tig Argon Arc Welding, Pointer:- Aluminium Black Coloured, Needle:- Micrometer Zero Adjustment, Pressure Range:- As Per Table, Process Connection:- 1/2 Npt (M), Accuracy : +/- 1% Fsd. Over Range Protection:- 130% Of Fsd,Process Temperature:- Max.300 Deg C, Blow Out Disc:- Neoprene (At The Back Side Of Case), Diaphragm Material:- Ss 316L/Hastelloy C+ Ptfe, Upper Chamber Material:- Ss 316, Low Chamber Material:-Ss 316/Hastelloy C + Ptfe , Sealing Liquid:- Silicon Oil (Dc-200), Snubber:-1/2Npt (F) X 1/2Npt (M) In Ss316 + 3 Way Gauge Cock (Mxfxf) , .-1 To 1 Kg/Cm2 , 0 To 0.6Kg/Cm2 , 0 To 1 Kg/Cm2 , 0 To 2.5 Kg/Cm2 , 0 To 4 Kg/Cm2 , 0 To 6 Kg/Cm2 , 0 To 10 Kg/Cm2 , 0 To 16 Kg/Cm2 , 0 To 25 Kg/Cm2 , 0 To 40 Kg/Cm2 , 0 To 60 Kg/Cm2 , 0-2000 Mmwc , Pressure Gaugesdial Size :- 6”(150Mm), White Back Ground With Black Markingmounting:-Bottom Entry, Local Mounting Case & Bezel:- Ss 304 Bayonet Lock Type,Weatherproof To Ip-68 As Per Iec68 As Per Iec:60529Windows :- Shatterproof Glass,Bourdon :- Ss316socket:- Ss316, Movement:- Ss304 Connection:- ½” Npt(F) With Adaptor, Accuracy:- +/- 1% F.S.D. Overrange:- 130% F.S.D., Zero Reset:- Provide Micrometer Point , Blow Out Disc:- Provided (Neoprene) On Top Of Case Snubber:-1/2Npt (F) X 1/2Npt (M) In Ss316 + 3 Way Gauge Cock , 0-400Kg/Cm2 , 0-160Kg/Cm2 , 0-60Kg/Cm2 , 0-40Kg/Cm2 , 0-25Kg/Cm2 , 0-16Kg/Cm2 , 0-6 Kg/Cm2 , 0-4 Kg/Cm2 , 0-2.5 Kg/Cm2 , 0-1 Kg/Cm2 , -1 To +1 Kg/Cm2 , 0 – 1.6 Kg/Cm2 , 0 To 0.6 Kg/Cm2 , 0 To 100 Mmwc , Pressure Gauge Dial Size :- 10”(250Mm), White Back Ground With Black Markingmounting:-Bottom Entry, Local Mounting Case & Bezel:- Ss 304 Bayonet Lock Type,Weatherproof To Ip-68 As Per Iec68 As Per Iec:60529, Windows:- Shatterproof Glass, Bourdon:- Ss316,Socket:- Ss316, Movement:- Ss304, Connection:- ½” Npt(F) Through Adaptor,Accuracy:- +/- 1% F.S.D., Overrange:- 130% F.S.D. , Zero Reset:- Provide Micrometer Point Blow Out Disc:- Provided (Neoprene) On Top Of Caseoperating Temperature:- 0-560 Deg C , 0-400Kg/Cm2 S , 0-400Kg/Cm2 , Pressure Gaugedial Size :-6”(150Mm), White Back Ground With Black Marking Mounting:- Direct Mounting,Entry:-Bottomcase & Bezel:- Ss 304 Bayonet Lock Typeweatherproof To Ip-68 As Per Iec68 As Per Iec:60529 Windows :- Shatterproof Glass, Bourdon :- Ss316socket:- Ss316, Movement:- Ss304, Least Count:-20 Mm Hg/ 0.05 Kg/Cm2, Connection:- ½” Bsp(M), Accuracy:- +/- 1% F.S.D., Overrange:- 130% F.S.D. ,Zero Reset:- Provide Micrometer Point, Blow Out Disc:- Provided (Neoprene) On Top Of Case , (-)1 To 2.5 Kg/Cm2 , 0 To 760 Mm Hg , 0 - 6 Kg/Cm2. , 0 - 10 Kg/Cm2. , Pressure Gauge Dial Size :-6”(150Mm), White Back Ground With Black Marking Mounting:- Flushmounting, Entry:-Eccentric Back / Lower Back, Case & Bezel:- Ss 304,Weaterproof To Ip-68 As Per Iec68 As Per Iec:60529,Windows:- Shatterproof Glass, Bourdon:- Ss316,Socket:- Ss316,Movement:- Ss304, Least Count:- 0.05 Kg/Cm2connection:- ½” Bsp(M), Accuracy:- +/- 1% F.S.D. ,Overrange:- 130% F.S.D.,Zero Reset:- Provide Micrometer Point Blow Out Disc:- Provided (Neoprene) On Top Of Case , 0To 760 Mm Hg , Pressure Gauge Dial Size :-4”(100Mm), White Back Ground With Black Markingmounting:- Flush Mounting, Entry:- Back Entrycase & Bezel:- Ss 304 / Ss 316 (Silicon Oil Filled Case) Weatherproof To Ip-68 As Per Iec68 As Per Iec:60529 Windows:- Shatterproof Glass Bourdon:- Ss316socket:- Ss316movement:- Ss304 Least Count:-0.20 Kg/Cm2, Connection:- ½” Bsp(M) Accuracy:- +/- 1% F.S.D. Overrange:- 130% F.S.D.Zero Reset:- Provide Micrometer Point, Blow Out Disc:- Provided (Neoprene) On Top Of Case , Range:- 0 - 10 Kg/Cm2 , Range:- 0 - 25 Kg/Cm2 , Pressure Gauge Dial Size :-4”(100Mm),White Back Ground With Black Marking Mounting:-Local Mounting, Entry:- Bottom Entrycase & Bezel:- Ss 304 / Ss 316 (Silicon Oil Filled Case)Weatherproof To Ip-68 As Per Iec68 As Per Iec:60529Windows:- Shatterproof Glass, Bourdon:- Ss316socket:- Ss316 Movement:- Ss304, Least Count:-0.1 Kg/Cm2, Connection:- ½” Bsp(M) Accuracy:- +/- 1% F.S.D.Overrange:- 130% F.S.D. Zero Reset:- Provide Micrometer Point,Blow Out Disc:- Provided (Neoprene) On Top Of Case , Range:- 0 - 25 Kg/Cm2 , Range:- 0 - 40 Kg/Cm2 , Range:- 0-250 Kg/Cm2 , Pressure Gauge Dial Size :-6”(150Mm), White Back Ground With Black Markingmounting:- Flush Mounting, Entry:- Back Entrycase & Bezel:- Ss 304 / Ss 316Weatherproof To Ip-68 As Per Iec68 As Per Iec:60529 Windows:- Shatterproof Glass Bourdon:- Ss316socket:- Ss316movement:- Ss304 Least Count:-0.20 Kg/Cm2, Connection:- ½” Bsp(M) Accuracy:- +/- 1% F.S.D. Overrange:- 130% F.S.D.Zero Reset:- Provide Micrometer Point, Blow Out Disc:- Provided (Neoprene) On Top Of Case , Range:- 0 - 10 Kg/Cm2 , Range:- 0 - 25 Kg/Cm2 , Range:- 0-40 Kg/Cm2 , Range:- 0-60 Kg/Cm2 , Range:- 0-150 Kg/Cm2 , Range:- 0-250 Kg/Cm2 , Differential Pressure Gaugedial Size :-6”(150Mm), White Back Ground With Black Markingmounting:- Flush Mounting , Entry:- Back Entrycase & Bezel:- Ss 304 / Ss 316 With Bayonet Bazel Weather Proof To Ip-68 As Per Iec68 As Per Iec:60529 Windows:- Shatterproof Glasssensing Material:-Bellowsensor Material & Wetted Parts:- Ss316 / Ss316l / Monel/ Hastelloy-C, Movement:- Ss304 / Ss316least Count:-0.10 Kg/Cm2 Connection:- ½” Bsp(M) Accuracy:- +/- 1% F.S.D.Overrange:- 130% F.S.D.Zero Reset:- Provide Micrometer Point Blow Out Disc:- Provided (Neoprene) On Top Of Case Temperature Suitabilty:- Ambient (-)20 Deg C To 60 Deg C, Media 100 Deg C , Range:-0-4Kg/Cm2 , Temperature Gauge(Gas Filled) Gas (N2) Filled, Case Compensated In Accordance With Sama Cl. Iiib Dial Size - 150 Mm, Case & Bazel - Ss304 /Ss316 With Bayonet Bezeldial & Scale - Dial Will Be Made Of Suitable Material Black Figure On White Back Ground, Pointer:- Aluminium, Black With Micrometer Adjustment Protection:- Weatherproof To Ip-68 (Is/Iec:60947 / Iec : 60529) Window:- Shatterproof Glass, Stem:- Ss316,Capillary-Ss316 With Ss304 / Ss316 Armouring, With Pvc Covering & It Can Be Bent In To A Surface Of 100 Mm Dia, Mounting - Localmounting Bottom Entry,Connection:-1/2 Npt (M) Adjustable Three Piece Compression Fitting In Ss304/Ss316, Accuracy- ±1% Fsd, Over Range Protection- 125% Of Fsd, Reset:- Micrometer Pointer ,Bulb Material- Ss 316 , Probe Dia - 6 Mm, Stem Length- 200 Mm (Rigid) , Range 0 To 120 Deg C , Range 0 To 150 Deg C , Range 0 To 250 Deg C , Range 0 To 400 Deg C , Range 0 To 600 Deg C , Probe Dia - 8 Mm, Stem Length- 200 Mm (Rigid) , Range 0 To 120 Deg C , Range 0 To 150 Deg C , Range 0 To 250 Deg C , Range 0 To 400 Deg C , Range 0 To 600 Deg C , Probe Dia - 10 Mm, Stem Length- 200 Mm (Rigid) , Range 0 To 120 Deg C , Range 0 To 150 Deg C , Range 0 To 250 Deg C , Range 0 To 400 Deg C , Range 0 To 600 Deg C , Probe Dia - 10 Mm, Stem Length- 300 Mm (Rigid) , Range 0 To 120 Deg C , Range 0 To 150 Deg C , Range 0 To 250 Deg C , Range 0 To 400 Deg C , Range 0 To 600 Deg C , Probe Dia - 6 Mm, Stem Length- 200 Mmcapillary Length – 5 Mtrrange 0 To 250 Deg C , Probe Dia - 8 Mm, Stem Length- 200 Mmcapillary Length – 5 Mtr Range 0 To 250 Deg C , Probe Dia - 10 Mm, Stem Length- 200 Mm Capillary Length :- 5 Mtrrange 0 To 250 Deg C , Probe Dia - 6 Mm, Stem Length- 300 Mm Capillary Length :- 5 Mtr , Range 0 To 120 Deg C , Range 0 To 250 Deg C , Range 0 To 400 Deg C , Probe Dia - 8 Mm, Stem Length- 300 Mm Capillary Length :- 25 Mtr Range 0 To 150 Deg C , Probe Dia - 10 Mm, Stem Length- 200 Mm Capillary Length :- 5 Mtr , Range 0 To 150 Deg C , Range 0 To 250 Deg C , Range 0 To 400 Deg C , Range 0 To 600 Deg C , Probe Dia - 10 Mm, Stem Length- 300 Mm Capillary Length :- 25 Mtr , Range 0 To 150 Deg C , Range 0 To 400 Deg C , Probe Dia - 12 Mm, Stem Length- 300 Mm Capillary Length :- 5 Mtr , Range 0 To 120 Deg C , Range 0 To 400 Deg C , Range 0 To 600 Deg C , Temperature Gauge(Gas Filled) Gas (N2) Filled, Case Compensated In Accordance With Sama Cl. Iiib Dial Size;- 150 Mmcase & Bezel- Ss304 /Ss316 With Bayonet Bezel Dial & Scale- Dial Will Be Made Of Suitable Material Black Figure On White Back Groundpointer:- Aluminium, Black With Micrometer Adjustment Protection:-Weatherproof To Ip-68 (Is/Iec:60947 / Iec : 60529) Window:- Shatterproof Glass Stem:- Ss316 Capillary-Ss316 With Ss304 / Ss316 Armouring, With Pvc Covering & It Can Be Bent In To A Surface Of 100 Mm Diamounting - Panel Mountingback Entry Connection:-1/2 Npt (M) Adjustable Three Piece Compression Fitting In Ss304/Ss316 Accuracy- ±1% Fsd, Over Range Protection- 125% Of Fsd,Reset:- Micrometer Pointerbulb Material- Ss 316 , Probe Dia - 6 Mm, Stem Length- 200 Mm Capillary Length :- 5 Mtr Range 0 To 120 Deg C , Probe Dia - 8 Mm, Stem Length- 200 Mm Capillary Length :- 5 Mtr Range 0 To 120 Deg C , Probe Dia - 8 Mm, Stem Length- 300 Mm Capillary Length :- 5 Mtr Range 0 To 120 Deg C , Probe Dia - 10 Mm, Stem Length- 200 Mm Capillary Length :- 5 Mtr Range 0 To 120 Deg C , Probe Dia - 10 Mm, Stem Length- 300 Mm Capillary Length :- 5 Mtr Range 0 To 120 Deg C , Temperature Gauge(Gas Filled)Gas (N2) Filled, Case Compensated In Accordance With Sama Cl. Iiib Dial Size;- 100 Mm , Case & Bezel- Ss304 /Ss316 With Bayonet Bezeldial & Scale- Dial Will Be Made Of Suitable Material Black Figure On White Back Groundpointer:- Aluminium, Black With Micrometer Adjustment Protection:- Weatherproof To Ip-68 (Is/Iec:60947 / Iec : 60529) Window:- Shatterproof Glass Stem:- Ss316, Capillary-Ss316 With Ss304 / Ss316 Armouring, With Pvc Covering & It Can Be Bent In To A Surface Of 100 Mm Dia Mounting - Panel Mountingback Entry Connection:-1/2 Npt (M) Adjustable Three Piece Compression Fitting In Ss304/Ss316accuracy- ±1% Fsd,Over Range Protection- 125% Of Fsd,Reset:- Micrometer Pointer Bulb Material- Ss 316 , Probe Dia - 6 Mm, Stem Length- 200 Mm Capillary Length :- 5 Mtr Range 0 To 120 Deg C , Probe Dia - 8 Mm, Stem Length- 200 Mm Capillary Length :- 5 Mtr Range 0 To 120 Deg C , Probe Dia - 8 Mm, Stem Length- 300 Mm Capillary Length :- 5 Mtr Range 0 To 120 Deg C. Last date of submission for this tender is 2025-04-17. This is a Pressure Gauge tender in Betul, Madhya Pradesh

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

6 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in