🎉 Your free trial plan has started. Plan will expire in 0 days

Madhya Pradesh Power Generating Company Limited

dongalia, madhya pradesh

AOC value
₹5.31L
AOC date
9 Dec
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 9 Dec 22AOC date

Important info

Result ID
Refer Docs
Award of contract
09/12/2022
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Madhya Pradesh Power Generating Company Limited has published Procurement Of Insulation Tester For Electrical Maintenance Division And Instrument Division Of Ph-1, Sstpp, Khandwa , 5 Kv Insulation Tester Specification :- Specially Used In Switchyard & High Induction Area 1. Measurement Parameter:- Insulation Resistance, Pi, Dar, Leakage Current, Voltage And Temperature 2. Pre-Set Test Dc Voltage Range:- 250V, 500V, 1Kv, 2.5Kv, 5Kv In Steps 3. Resistance Measurement Range :-10Kohm- 10 Tohm Or Better 4. Short Circuit Current :-Minimum 2Ma Or Better 5. Basic Accuracy:-±5% 6. Response Time :- 15S Max 7. Leakage Current Measurement:- Minimum1.00Na 8. Safety:-Iec 61010-1 ( Cat Iv 600 V To 3000 M Altitude ) 9. Battery Backup :- 8 Hours Minimum 10. Charging Supply:- 230V, 50Hz 11. Digital Display:- Lcd / Led Display With 3 &1 / 2 Digit. 12.Operating Temperature:- ( -10 ) Deg C T0 40 Deg C 13. Ip Standard:- Ip65 ( Lid Closed ) , Ip40 ( Lid Open ) , 14. Continuous Operating Time:- Minimum 5 Hours 15. Accessories : - Test Leads 2Set With Each Tester, User Manual, Calibration Sheet , 5 Kv Insulation Tester Specification :- 1. Measurement Parameter:- Insulation Resistance, Pi, Dar, Leakage Current, Voltage And Temperature 2. Pre-Set Test Dc Voltage Range :- 250V, 500V, 1Kv, 2.5Kv, 5Kv In Steps 3. Resistance Measurement Range :-10Kohm- 10 Tohm Or Better 4. Short Circuit Current :-Minimum 2Ma Or Better 5. Basic Accuracy:-±5% 6. Response Time :- 15S Max 7. Leakage Current Measurement:- Minimum1.00Na8. Safety :-Cat1v 9. Battery Backup :- 8 Hours Minimum 10. Charging Supply:- 230V, 50Hz 11. Digital Display :- Lcd / Led Display With 3 &1 / 2 Digit. 12.Operating Temperature :- ( -10 ) Deg C T0 40 Deg C 13. Ip Standard :- Ip40 14. Continuous Operating Time :- Minimum 5 Hours 15. Accessories : - Test Leads 2Set With Each Tester, User Manual, Calibration Sheet , 1 Kv Insulation Tester Specification1. Measurement Parameter:- Insulation Resistance, Voltage2. Pre-Set Test Dc Voltage Range :- 250V, 500V, 1Kv, In Steps 3. Resistance Measurement Range:-0.00 Mohm- 3000 Mohm 4. Basic Accuracy: - ±5% 6. Safety :-Cativ 7. Battery Backup:- 8 Hours Minimum 8. Charging Supply :- 230V, 50Hz 9.Digital Display:- Lcd / Led Display With 3 &1 / 2 Digit. 10.Operating Temperature :- ( -10 ) Deg C T0 40 Deg C 11. Ip Standard:- Ip40 12. Continuous Operating Time :- Minimum 5 Hours 13. Accessories : - Test Leads 2Set With Each Tester, User Manual, Calibration Sheet. Last date of submission for this tender is 2021-09-15. This is a Electrical Maintenance tender in Dongalia, Madhya Pradesh

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in