🎉 Your free trial plan has started. Plan will expire in 0 days

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited

bhopal, madhya pradesh

AOC value
₹51.76L
AOC date
5 Aug
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 5 Aug 22AOC date

Important info

Result ID
Refer Docs
Award of contract
05/08/2022
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited has published Rate Contract For Supply Installation Commissioning And Testing Of Scada Rt Das Equipments At Various Locations In Mpmkvvcl - 1 Remote Terminal Unit ( Rtu ) For 2 No. Power Transformer ( Having 1 Mcu 6A, 1 Power Card, 5 Di Card Of 32 Digital Input, 3 Do Card Of 16 Digital Output, 1 Dcai Card, 1 Com 6 Cards, 1 Dc Voltage Transducer ) With Communication Protocol Iec 103 / 61850 Ed2, Dnp 3.0, Modbus, Etc., 48V Operated, With Space To Accomodate 1 Number Additional Rack 2 Multi Function Transducer 48V ( 5 Amp, 110 V With Rs485 Modbus Communication Protocol 3 Contact Multiplying Relays ( Cmrs ) With 2No + 1 Nc Operating At 30V Dc 4 Heavy Duty Relay ( Hdr ) For Cb Trip / Close ( 48V Dc, 2 No, 1 Nc ) 5 Ldms Along With Necessary Ldms Software License And Convertor 48V Dc To 230V Ac, 200 W ( Along With One Chair And One Table ) 6 48 V Dc Power Supply ( Dcps ) System Based On Smps 7 Dcps Battery Set ( 48 V, 150 / 160 Ah ) Capacity 8 Numerical Relay Scada Compatible For 33 Kv & 11 Kv Feeder Protection 9 Auxiliary Relay ( Mtr ) 4 No And 4Nc, 30V Dc, 10 Amp 10 Scada Compatible Winding Temperature Indicator ( Wti ) , Dial 150Mm, With Capilary, Mercury Swicth Type 11 Scada Compatible Oil Temperature Indicator ( Oti ) , Dial 150Mm, With Capilary, Mercury Swicth Type 12 11Kv / 33Kv Stand-Alone Fault Passage Indicator ( 1 Gateway / Frtu + 3 Fpi ) Complete With Gprs Enabled Modem ( Scada Compatible ) 13 11Kv / 33Kv Stand-Alone Fault Passage Indicator ( 1 Gateway / Frtu + 6 Fpi ) Complete With Gprs Enabled Modem ( Scada Compatible ) 14 11Kv / 33Kv Stand-Alone Fault Passage Indicator ( 1 Gateway / Frtu + 9 Fpi ) Complete With Gprs Enabled Modem ( Scada Compatible ) 15 Battery For 11Kv Stand-Alone Fault Passage Indicator ( Fpi ) 3.6V-2000 Mah 16 Battery For 11Kv Stand-Alone Fault Passage Indicator ( Frtu / Gateway ) 12V - 21Ah 17 Ac / Dc Auxiliary Supply Board With Suitable Mcb & Fuse Protection 18 Earthing Of Rtu / Frtu Panel 19 Frtu Supply & Installation:- Comprising Panels, Racks, Sub-Racks, Power Supply Modules, Minimum 02 Cards Of 32 Digital Input Module, Cpu Analog Mcu Card With Minimum 03 Ethernet Port04 Com Port, Dcai, 1 Dc Voltage Transducer & Support All Standard Protocol Iec ( I.E. 103, 61850, 104, Modbus ) , Dcps ( 24V ) With Dual Battery Of Minimum 4 Hrs Backup As Per Specification Interfacing Equipment Along With 30V Dc To 24V Dc Convertor, Dual Sim 4G Modem With Active-Active Mode With Fallback Facility Of 4G / 3G / 2G, And 50% Additional Space For Modules As Well As Space For 1 Number Additional Rack 20 Multi Function Transducer 24V ( 5 Amp, 110 V With Rs485 Modbus Communication Protocol 21 Dc Voltage Transducer 22 Dual Sim 4G Router / Modem With Active-Active Mode With Fallback Facility Of 4G / 3G / 2G 23 Additional Rack For Rtu / Frtu 24 Mcu 6A Module Card Master 48V Operated 25 Mcu 1A Module Card Master 48V Operated 26 Mcu 4A Module Card Slave 48V Operated 27 Mcu 6A Module Card Master 24V Operated 28 Mcu 1A Module Card Master 24V Operated 29 Mcu 4A Module Card Slave 24V Operated 30 Power Module Card 48V Operated 31 Power Module Card 24V Operated 32 Di Card Having 32 Digital Input, 48V Operated 33 Di Card Having 32 Digital Input, 24V Operated 34 Do Card Having 16 Digital Output, 48V Operated 35 Do Card Having 16 Digital Output, 24V Operated 36 Ai Card Having 8 Analog Input, 48V Operated 37 Com 6 Card, 48V Operated 38 Dcps ( 24V ) With Dual Battery Of Minimum 4 Hrs Backup 39 Convertor 48V Dc To 230V Ac ( 200 Watt ) 40 Convertor 30V Dc To 48V Dc ( 400 Watt ) 41 Convertor 30V Dc To 24V Dc ( 200 Watt ) 42 Scada Rtu Installation On Suitable Stand / Civil Structure 43 Scada Rtu Commissioning & Integration With Control Center, Creation Of Database, Sld And End To End Testing 44 Rt-Das Frtu Commissioning & Integration With Control Center, Creation Of Database, Sld And End To End Testing 45 Scada Feeder Panel Retrofitting And Termination Of Either Ends Including All Cables, Lugs, Ttb, Connectors And Accessories Etc. 46 Scada Ptr Panel Retrofitting And Termination Of Either Ends Including All Cables, Lugs, Ttb, Connectors And Accessories Etc. 47 Scada Capacitor Bank Retrofitting And Termination Of Either Ends Including All Cables, Lugs, Ttb, Connectors And Accessories Etc. 48 Rt-Das Feeder Panel Work With Termination Of Either Ends Including All Cables, Lugs, Ttb, Connectors And Accessories Etc. 49 Rt-Das Ptr Panel Work With Termination Of Either Ends Including All Cables, Lugs, Ttb, Connectors And Accessories Etc. 50 Rt-Das Capacitor Bank Panel Work With Termination Of Either Ends Including All Cables, Lugs, Ttb, Connectors And Accessories Etc.. Last date of submission for this tender is 2022-03-02. This is a Connectors Supply tender in Bhopal, Madhya Pradesh

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in