🎉 Your free trial plan has started. Plan will expire in 0 days

Rural Development Department

kasaragod, kerala

AOC value
₹14.89L
AOC date
4 Nov
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 4 Nov 25AOC date

Important info

Result ID
Refer Docs
Award of contract
04/11/2025
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Rural Development Department has published Providing Fire And Safety To Rrf Nileshwar Block Pancahyath Providing Fire And Safty To Rrf Block Panchayth Nileshwar , Items , Hydrant - 1.Provide One Hydrant For 100 Meter Square Area. (As Per The Circular) No. Wm1/40/2022/Lsgd (Wm) Dtd. 02.02.2022) 2.Hydrant As Per Is 3844:19893. Diameter Of Delivery Pipe- 100Mm 4. Material G.I Pipe 5. Colour- Red 6.Hydrant Should Be Placed Outside The Building Minimum 02 Mtr Away From The Building , Accessories - 1.63Mm Diameter Female Coupling With Single Head Landing Valve 2. Delivery Hose - 63Mm Diameter, 15 Mtr Length With Male And Female Coupling 3.Branch Pipe- With 20Mm Nozzle And Suitable For 63Mm, Instantaneous Connection , Hose Box- Above Three Accessories Shall Be Housed In A 750*600*250 Mm Size Ms Cabinet Made From 2 Mm Thick Ms Sheet With Glass Door Of Thickness 6 Mm. The Cabinet Shall Be Painted With Red Colour Shade No.536 As Per Is5. , Water Tank - 1. Capacity - Minimum 50000 Ltr. For 500 Meter Sqare Built Up Area. 2. For Additional 100 Meter Square Area 10000 Ltrs. Each To Be Added3. Tank Should Be Separated As Minimum Two Compartments To Be Interconnected Externally 4. While Pump Installations Positive Sunction Should Be Ensured , Diesel Pump - 1. Discharge - 1620 Lpm (As Per The Circular No. Wm1/40/2022/Lsgd (Wm) Dt. 02.02.2022) 2.Head - Not Less Than 35 Mtr 3. Diesel Pump Should Be Installed Inside The Pump House (Bis- 15303) 4.Exhaust Pipe Of The Diesel Pump Should Be Fitted Vertically Above The Pump House In Such A Way That The Smoke Goes Directly To The Atmosphere5. Adequate Number Of Fire Extinguishers Shall Be Installed In The Pump House , Fire Bucket - A Fire Bucket Is A Bucket Fitted With Water Or Sand Which Is Used To Prevent Or Extinguish Fires 1.Material Ms Galvanized Sheet2.Top Dia 260Mm 3.Height 270 Mm4. Body Thickness 2.8 Mm5.Painting Two Coats Of White Paint Inside Two Coats Of Red Paint Out Side . Ear And Handle Painted Black.Letter Fire Painted Centrally In Black Color (75Mm Height And 12Mm Thick) 6. Minimum 04 Nos .Should Be Arranged In Metallic Stand Which Should Be Easily Accessibility And Visiblebody- The Body Shall Be In Two Halves Which Shall Be Joined Together By Butt Wlding. The Top Rim Of The Body Shall Be Wired And Unformly Beaded. The Beading Shall Be Fully Formed Without Gaps. The Bottom Shall Be Dished And Shall Be Joined To The Bodyby Butt Welding So That There Is No Raw Edge Or Crevice On The Inside Of The Bucket Ears- The Ears Shall Be Made Of Mild Steel Sheet And Shall Be Fitted To The Body At The Top By Means Of Welding With The Flat Head On The Side. The Thickness Of Sheet For Ears Shall Be 2.8 Mm Top Handle- The Top Handle Shall Be Mild Steel Road Of 10Mm In Diameter With Its Ends Bent Up , Fire Bucket - A Fire Bucket Is A Bucket Fitted With Water Or Sand Which Is Used To Prevent Or Extinguish Fires 1.Material Ms Galvanized Sheet2.Top Dia 260Mm 3.Height 270 Mm4. Body Thickness 2.8 Mm5.Painting Two Coats Of White Paint Inside Two Coats Of Red Paint Out Side . Ear And Handle Painted Black.Letter Fire Painted Centrally In Black Color (75Mm Height And 12Mm Thick) 6. Minimum 04 Nos .Should Be Arranged In Metallic Stand Which Should Be Easily Accessibility And Visiblebody- The Body Shall Be In Two Halves Which Shall Be Joined Together By Butt Wlding. The Top Rim Of The Body Shall Be Wired And Unformly Beaded. The Beading Shall Be Fully Formed Without Gaps. The Bottom Shall Be Dished And Shall Be Joined To The Bodyby Butt Welding So That There Is No Raw Edge Or Crevice On The Inside Of The Bucket Ears- The Ears Shall Be Made Of Mild Steel Sheet And Shall Be Fitted To The Body At The Top By Means Of Welding With The Flat Head On The Side. The Thickness Of Sheet For Ears Shall Be 2.8 Mm Top Handle- The Top Handle Shall Be Mild Steel Road Of 10Mm In Diameter With Its Ends Bent Up , Fire Rake- 1. Length - Not Less Than 2 Mtr2. Head- Shall Not Be More Than 1 Feet Wide3. Teeth - Shall Be 10 Cm Long 4. 7 Teeth At An Interval Of 2 Inches Shall Be Provided , Fire Beater - The Main Purpose Of The Fire Beater Is To Pull Out Small Fires. It Should Be User Friendly And The Pipe Should Not Be Bend While Using The Fire Beater In Fire Conditions. Total Weight Of The Fire Beater Shall Be Designed In Such A Way That Fire Personnel Can Comfortably Use This During The Fire Conditions1.It Should Have Mainly 3 Part- Metal Pipe. Metal Stripand Rubber Mata) Gi Metal Pipe- Diameter Should Be 32 Mm Length- Should Not Be Less Than 1.5 Meterb) Rubber Mat- A Thin Metal Mesh Or Wire Should Be Provided Inside The Matthickness- 0.5 Cm, Length45cm,Bredth-3Cm,Thickness- 0.2Cm,Nut&Bolt- 5Nos2. Metal Pipe Should Be Welded On The Metal Strip 3. Rubber Mat Shall Be Fitted To The Strip By Using Nut & Bolt4. Additioanl Metal Support Should Be Given To The Strip For Ensuring Adequate Strength. Last date of submission for this tender is 2025-08-25. This is a Fire Extinguishers tender in Kasaragod, Kerala

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

6 issued
  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3xlsx
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in