Military Engineer Services
- AOC value
- ₹27.45L
- AOC date
- 18 Nov
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- 18 Nov 20AOC date
- -Published
- -Closes
- -Bid opens
- 18 Nov 2020AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- 18/11/2020
- Authority
- Military Engineer Services
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Military Engineer Services has published Outsourcing Services For Manning And Operation Of Substations No 1 4 And 9 Under Age E_M Maint At Ina Ezhimala As Per Boq And Tender Documents , Note Applicable For All Items Of Boq:- ( For Special Attention Of Bidders ) If The Lowest Quoted Amount Is Less Than The Estimated Cost Of The Work Mentioned In Nit , The Lowest Bidder Will Have To Submit Fdr/Bgb In Favour Of Accepting Officer Within 7 ( Seven ) Days Of Opening Of Financial Bid For The Difference In Estimated Cost And Quoted Amount . In Case The Said Fdr/Bgb Is Not Submitted Within Stipulated Period As Mentioned Above , The Contractor Shall Be Banned For 6 Months And His Bid Will Be Rejected . Fdr/Gbg Will Be Released Only After Completion Of Entire Work And Production Of Proof For The Payment Of Wages To All The Workers Employed Under The Contract Is Paid Not Less Than The Minimum Wages Notified By The Central Govt . /State Govt . Whichever Is More , Outsourcing Services For Operation Of 11 Kv Substation No 1 Comprising Of Ht/Lt Switch Gears , Ht/Lt Machineries And All Connected Accessories Mentioned Below Round The Clock Including Sundays And Holidays By Employing Two Skilled Iti Qualified Electrician Per Each Shift ( 0600Hrs To 1400 Hrs , 1400 Hrs To 2200 Hrs And 2200 Hrs To 0600 Hrs ) And To Carry Out The Following Routine Works As Directed By Engineer- In- Charge . The Equipments Details Are:- ( A ) 11 Kv 400 Amps Vacuum Circuit Breaker With Relays And Controls - 07 Nos . ( B ) 11Kv/433 V Step Down Transformer Of Capacity 100 Kva - 01 No . ( C ) Lt Control Panel - 01 No . ( D ) 11 Kv Metering Panel - 01 No ( E ) Battery Bank With Battery Charger - 01 No . ( F ) Ht Bus Coupler With Ring Main Supply System - 01 Set ( G ) Dg Det 01 Nos , Outsourcing Services For Operation Of 11 Kv Substation No 4 Comprising Of Ht/Lt Switch Gears , Ht/Lt Machineries And All Connected Accessories Mentioned Below Round The Clock Including Sundays And Holidays By Employing One Skilled Iti Qualified Electrician Per Shifts ( 0600Hrs To 1400 Hrs , 1400 Hrs To 2200 Hrs And 2200 Hrs To 0600 Hrs ) And To Carry Out The Following Routine Works As Directed By Engineer- In- Charge . The Equipment Details Are :- ( A ) 11 Kv 400 Amps Vacuum Circuit Breaker With Relays And Control- 04 Nos . ( B ) 11 Kv Osfu 400 Amps- 03 Nos . ( C ) 11Kv/433 V Step Down Transformer Of Capacity 315 Kva- 02 No . ( D ) Lt Control Panel - 01 No . ( E ) Pf Improvement Capacitor Panel - 01 No . ( F ) Battery Bank With Battery Charger- 01 No . , Outsourcing Services For Operation Of 11 Kv Substation No 9 Comprising Of Ht/Lt Switch Gears , Ht/Lt Machineries And All Connected Accessories Mentioned Below Round The Clock Including Sundays And Holidays By Employing Two Skilled Iti Qualified Electrician Per Shifts ( 0600Hrs To 1400 Hrs , 1400 Hrs To 2200 Hrs And 2200 Hrs To 0600 Hrs ) And To Carry Out The Following Routine Works As Directed By Engr- In- Charge . The Equipment Details Are :- ( A ) 11 Kv 400 Amps Vacuum Circuit Breaker With Relays And Control- 11 Nos . ( B ) 11Kv/433 V Stepdown Transformer Of Capacity 500 Kva- 01 No . ( C ) 11Kv/433 V Stepdown Transformer Of Capacity 1000 Kva- 02 Nos . ( D ) Lt Control Panel - 03 Nos . ( E ) Pf Improvement Capacitor Panel - 01 No . ( F ) Battery Bank With Battery Charger- 01 No . ( G ) Ht Bus Coupler With Ring Main - 01 No . ( H ) Dg Set 320 Kva- 01 No . ( J ) Dg Set Panel - 01 No . , Notes For Sl Item No 02 , 03 & 04 ( I ) Spares If Any Required For Replacement Shall Be Supplied By Mes ( Ii ) The Tradesmen Shall Be Well Qualified In Respective Trade And Shall Wear Approved Uniform As Directed By Engineer- In- Charge While On Duty . He Shall Be Well Conversant With Preventive Measures ( First Aid ) In Case Of Electrical Accidents And Fire Fighting Systems And Maintain Log Books For Sub Stations ( Iii ) The Unit Rate Quoted Shall Include Stationery Required To Maintain Attendance Register , Duty Roster , Payment Register , Display Board , Complaint Register , Log Sheet And Other Register As Directed By Engineer- In-Charge . The Unit Rate Also Include Distilled Water , Grease Etc For Battery Maintenanance , Cleaning Materials Like Cotton Waste Etc . ( Iv ) The Contractor Will Prepare Duty Roster Well In Advance And Got It Approved By Engineer - In- Charge And One Copy Of The Roster Shall Be Displayed In The Notice Board . ( V ) Supplying Of Stationary , Uniform , Tool And Plant Required For Day To Day Maintenance For Sub Station Maintenance All As Directed By Engineer In Charge . ( Vi ) Contractor Is Fully Responsible For Cleanliness Of The Area Of Substations . . Last date of submission for this tender is 2020-10-17. This is a Substation tender in Ezhimala, Kerala
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free